North Chicago VA Medical Center
North Chicago, Illinois, 60064, United States
NCT Number: NCT00564902
To evaluate if supplementation of zeaxanthin (with or without Lutein) is beneficial to patients with early and moderate Atrophic Age Related Macular Degeneration.
Looking for future studies?
Notify Me45 year–90 year
All sexes
Interventional
Not applicable
North Chicago, Illinois, 60064, United States
To evaluate whether or not zeaxanthin supplementation raises macular pigment optical density (MPOD). Previous research has shown MPOD to mirror visual benefits for patients with age related atrophic macular degeneration (AMD) having visual symptoms (decreased visual acuity, contrast sensitivity, photostress glare recovery and National Eye Institute Visual Function Questionnaire 25 scores), but lower risk National Eye Institute (NEI) / Age Related Eye Disease Study (AREDS) characteristics.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
8 mg per day during 12 months
Other names: EZEyes
9 mg of Lutein during 12 months
8 mg of lutein and 8 mg of Zeaxanthin administered during 12 months
Time frame: 4 months
Replicate measures of foveal 1 degree estimated central MPOD were evaluated with the Quantify® MPS 9000 macular pigment screener, a modified heterochromic flicker photometer (HFP). It employs alternating blue and green flickering LED's and fixation on a 1 degree target, so that a representative measurement at 0.5 degree off center from the fovea is calculated. The method has good repeatability (r = 0.97) and the data are comparable with an objective optical method based on retinal reflectometry (r = 0.78).
Time frame: 8 months
Replicate measures of foveal 1 degree estimated central MPOD were evaluated with the Quantify® MPS 9000 macular pigment screener, a modified heterochromic flicker photometer (HFP). It employs alternating blue and green flickering LED's and fixation on a 1 degree target, so that a representative measurement at 0.5 degree off center from the fovea is calculated. The method has good repeatability (r = 0.97) and the data are comparable with an objective optical method based on retinal reflectometry (r = 0.78).
Time frame: 12 months
Replicate measures of foveal 1 degree estimated central MPOD were evaluated with the Quantify® MPS 9000 macular pigment screener, a modified heterochromic flicker photometer (HFP). It employs alternating blue and green flickering light emitting diodes and fixation on a 1 degree target, so that a representative measurement at 0.5 degree off center from the fovea is calculated.
Time frame: 12 months
We determined the target deformation detection thresholds, or amplitude of the minimum detectable distortion of a 1 degree foveal circular target. The peak spatial frequency of RF (radial frequency) patterns was 5 cyc/deg; the radial modulation frequency was 8 cyc/360°; mean radii were 0.5°, 1°, 2.0°, or 2.5°; and stimulus contrast was 80%. The highest % modulation score possible is 0.13 while the easiest (lowest score) was 10% modulation.
Time frame: 12 months
Black and 10% contrast near reading visual acuity was assessed with a Colenbrander Mixed Contrast Reading Card with LogMAR letters (#4031, Precision Vision, LaSalle, Illinois). We determined single letter acuity on an ordinal VAS (Visual Acuity Scale). The largest letters were 0.05 LogMAR with a VAS = 35 while the most difficult smallest letters were LogMar 1.25 or VAS 105. The test card was held at 40 cm with best monocular refraction, and both low and high contrast letter acuity were assessed.
Time frame: 12 Months
Photostress glare recovery test involves exposing an individual eye to intense light, or retinal bleach, for a set duration of time and measuring the time taken for visual acuity to recover to a predetermined level. Glare photo-stress recovery (in seconds) following 30 seconds of continuous retinal bleach, was assessed using 2 line supra-threshold low contrast randomly presented Landolt Cs using the KOWA AS14B Night Vision Tester (KOWA Optimed, Tokyo, Japan).
Time frame: 12 Months
Distance photopic contrast sensitivity function (CSF) at 5 spatial frequencies (1.5, 3, 6, 12 & 20 cc/deg) was determined with the Functional Vision Analyzer® (Stereo Optical Co, Inc, Chicago, IL). Contrast sensitivity readings are shown as a curve. Visual acuity is plotted along the horizontal axis and contrast sensitivity along the vertical axis. Among the normally sighted people, both visual acuity and contrast sensitivity have a wide range of variation.Low population CSF is 0-200 units; normal population CSF is 200-300 units and suprathreshold CSF is 300+ units.
Time frame: 12 months
The ChromaTest© is a computerized psychophysical test of protan and tritan color thresholds against age-corrected data. The computer finds the endpoint of the test by a Modified Binary Search method; if response is correct, on the next presentation the color difference between letter and background is halved. If response is incorrect, the color -contrast is doubled. Incorrect responses prolong the test, but do not influence the final threshold. This method of determining thresholds leads to finite steps which reach a plateau at the color contrast sensitivity threshold.
Time frame: 12 Months
Scotomas within the central 20 degree central macula visual field sensitivity was assessed at 5 contrast levels (20, 40, 60, 80, and full contrast). A yellow wavelength stimulus avoided confounding by the lens. Subjects outlined the boundaries of their scotoma(s) on an area-integrating and recording touch flat- screen RGB monitor displaying a central fixation point and movable horizontal/vertical raster lines. The computer calculated summed area of the scotoma(s) with arbitrary scaling from 6000 (dense scotoma) to 0 relative units (absence of scotoma).
Chrysantis, Inc.
Industry
Randomized, Double Blind, Lutein Controlled Study of Zeaxanthin and Visual Function in Atrophic Age Related Macular Degeneration Patients
Acronym: ZVF
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02725762
Age Related Macular Degeneration, Eye Diseases
Toronto, Ontario, Canada
View Trial DetailsNCT03076697
Age Related Macular Degeneration, Cardiovascular Diseases
View Trial DetailsNCT07318428
Age Related Macular Degeneration, Cardiovascular Diseases
Busan, South Korea
View Trial DetailsNCT07424235
AMD, Age Related Macular Degeneration
View Trial Details