Current Status and Determinants of Care for Patients With Acute Chest Pain in China: A Retrospective Analysis of Data From the China Chest Pain Center Registry
NCT04014972
Acute Aortic Syndrome, Aneurysm
View Trial DetailsNCT Number: NCT01213589
The purpose of this post-market release registry is to collect additional information concerning safety, performance and health economic data with respect to the Medtronic VALIANT Thoracic Stent Graft with the Xcelerant Delivery System in the treatment of descending thoracic aortic dissections.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
The patient device for use in this registry is the Medtronic VALIANT Thoracic Stent Graft System that received CE mark approval in March 2005.
The Medtronic VALIANT Thoracic Stent Graft with Xcelerant Delivery System is designed to treat diseases of the descending thoracic aorta including but not limited to aneurysms and dissections. The VALIANT Stent Graft is designed to exclude the aneurysm, the false lumen or site of rupture and restore the blood flow through the stent graft lumen. The device is intended for use either in patients who are candidates for conventional surgical repair, and in patients who are not candidates for conventional surgical repair due to pre-existing risk factors.
This registry is a prospective, non-randomized, single-arm, multi-center, European clinical registry with patients diagnosed with descending thoracic aortic dissection.
For this registry standard hospital procedures with respect to patient interventional care for thoracic aortic diseases will be followed.
This is a descriptive registry in which no specific hypotheses will be statistically tested.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 12 months post-procedure
Disease, device or procedure-related mortality at 12 months post-procedure, defined as any death related to the device, to the disease or to the surgical procedure occurring in the period of 365 days following the day of the implant procedure.
Time frame: 30 days or at discharge, 3/6/12/24/36 months
Time frame: 30 days or at discharge, 3/6/12/24/36 months
Time frame: 30 days or at discharge, 3/6/12/24/36 months
Kaplan-Meier estimate of freedom from secondary procedures by clinical group.
Time frame: through 36 months
Complications were assigned a severity score (according SVS scores) so that degrees of morbidity can be assessed and compared. A moderate complication indicates the need for significant intervention, prolongation of hospitalization more than 24 hours, and at most, minor permanent disability that does not preclude normal daily activity. A severe complication necessitates major surgical or medical intervention, may be associated with prolonged convalescence, is usually accompanied by prolonged or permanent disability, and may result in death. Both moderate and severe complications are considered as major complications.
Kaplan-Meier estimate of freedom from disease-, procedure-, or device-related major complications by clinical group.
Time frame: through 36 months
Complications were assigned a severity score (according SVS scores) so that degrees of morbidity can be assessed and compared. A severe complication necessitates major surgical or medical intervention, may be associated with prolonged convalescence, is usually accompanied by prolonged or permanent disability, and may result in death.
Kaplan-Meier estimate of freedom from disease-, procedure-, or device-related severe complications
Time frame: through 36 months
Clinical success was defined as: (i) successful introduction and deployment of the Valiant Thoracic Stent Graft at the intended location; (ii) successful coverage of the proximal entry tear; (iii) no immediate conversion to open surgery;(iv) absence of surgical open repair or endovascular re-intervention; (v) absence of death related to aortic disease or treatment; (vi) absence of graft thrombosis, obstructions, twists or kinks; (vii) absence of graft migration;(viii) absence of graft integrity failure; (ix) at the level of the ostium of the LSA, the more proximal entry tear of the dissection, the largest section of the thoracic aorta, and at the first image/slice available with upper part of the liver:
Absence of true lumen decrease in diameter (≥ 5 mm is significant) Absence of increase in total aortic diameter (≥ 5 mm is significant)
Medtronic Endovascular
Industry
The VIRTUE Post Marketing Surveillance Registry - VALIANT Thoracic Stent Graft Evaluation For the Treatment of Descending Thoracic Aortic Dissections
Acronym: VIRTUE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04014972
Acute Aortic Syndrome, Aneurysm
View Trial DetailsNCT02380716
Acute Aortic Syndrome, Aneurysm
Los Angeles, California, United States
View Trial DetailsNCT04907071
Acute Aortic Syndrome, Aneurysm
London, Ontario, Canada
View Trial DetailsNCT03669055
Acute Aortic Syndrome, Aneurysm
Bron, France
View Trial Details