Skip to main content
OpenTrials
Recruiting

NCT Number: NCT05397951

The Validation Study of Bioelectronics

The purpose of this study is to investigate the safe wearability and basic functions of the multi-modality sensors fabricated in the PI lab.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year–99 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Kenan Laboratories at the University of North Carolina at Chapel Hill

Chapel Hill, North Carolina, 27514, United States

Location status: Recruiting

Location contact

Hannah L Weisbecker, BS

CONTACT

[email protected]

678-641-7484

Wubin Bai, PhD

PRINCIPAL_INVESTIGATOR

About this study

Members of this research team have developed innovative, wearable devices capable of being comfortably and continuously worn while recording diverse physiologic measurements. The purpose of this study is to validate the safe wearability and basic functions of the novel biocompatible electronic sensor that will allow continuous, non-invasive physiological measurements. This study aims to obtain preliminary data on the safety and functional aspects of the developed devices and compare it to approved medical equipments (including Abbott Medquip Oximeter, Omron blood pressure monitor, and Vicorder device for pulse wave velocity), which will pave the way for future study that focuses certain disease model. Participants will be randomly assigned to Condition A, and wear the devices before and after exercise for 15 minutes each time, or Condition B and wear the devices for 2 hours continuously. During their 1-hour or 2.5-hour lab visit, study participants will wear the biocompatible electronic sensors and three approved medical devices during a slow deep breath, before and after a 6-minute brisk walk, or for an extended period of time (2 hours). Participants will return to the lab for two brief visits, 48 and 96 hours after the device wearing, to determine if any suspected adverse events related to study procedures or devices emerged after they left the research site. For the future study, we will plan to 1) optimize the devices for use in patients needing FiO2 weaning, 2) demonstrate the reliability, and accuracy of these devices for continuous physiological measurements, including but not limited to blood pressure, heart rate (HR), cerebral blood flow, temperature, glucose concentration, and respiratory rate, and 3) demonstrate these devices are preferred by patients to current measurement tools. Once validated, such sensors could fundamentally change the way blood flow, blood pressure, or related parameters are monitored for patients, eliminating risks associated with invasive monitoring, allowing continuous, real-time detection of clinically meaningful changes in the patients, advancing knowledge of hormonal signatures and physiological signals preceding clinically meaningful events.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Individuals with ages between 18 and 99.
  • Healthy individuals (not known to suffer any significant illness relevant to the proposed study).

Exclusion criteria

  • Pregnant or lactating.
  • History of active (clinically significant) skin disorders that make skin vulnerable to contact conventional electronic devices.
  • History of allergic response to silicones or adhesives (such as 3M Tegaderm).
  • Broken, damaged or irritated skin or rashes near the sensor application sites (finger, wrist, temple, subclavian, arm, neck, and thigh).
  • Subjects who are physically or cognitively unable to normally perform activities of daily living, assessed at the discretion of the investigator to ensure safe completion of study tasks.
  • Subjects who are unable to participate in moderate exercise for 6 minutes.

Treatment and study plan

Multi-modality Noninvasive Biosensor

Device

The wearable sensor devices will be placed on the finger, wrist, temple, subclavian, arm, neck, and thigh of the participant and will provide continuous tissue mechanics, heart rate, respiration rate, blood flow, and pulse oxygenation measurements continuously throughout the experimental period.

Oximeter

Device

The oximeter device will be placed on the right middle finger of the participant and will provide continuous pulse oxygenation and heart rate measurements continuously throughout the experimental period.

Other names: Abbott Medquip

Portable Blood Pressure Monitor

Device

The blood pressure monitor device will be placed on the left arm of the participant and will take a blood pressure measurement every 5 minutes throughout the 15 minute experimental period, and every 15 minutes throughout the 2 hour experimental period.

Other names: Omron

Vicorder Pulse Wave Velocity Monitor

Device

The pulse wave velocity monitor device will be placed on the right side of the neck and the right thigh and will provide measurements continuously throughout the experimental period.

Primary outcomes

  1. Mean Comfort Level of Wearable Sensors

    Time frame: Questionnaire completed within 96 hours after device application.

    A questionnaire about the comfort of the wearable sensors will be measured using the Likert scale, which ranges from 1 to 5 and is used to measure attitudes and perception changes about the our sensor. The minimum value 1 represents "strongly disagree" and the maximum value 5 represents "strongly agree", thus higher scores represent a better outcome.

  2. Mean Safety Level of Wearable Sensors

    Time frame: Questionnaire completed within 96 hours after device application.

    A questionnaire about the safety and reactions to the wearable sensors will be measured using the Likert scale, which ranges from 1 to 5 and is used to measure attitudes and perception changes about the safety of our sensor. The minimum value 1 represents "strongly disagree" and the maximum value 5 represents "strongly agree", thus higher scores represent a better outcome.

  3. Mean Agreement Over Time of Physiological Parameters between Newly-Fabricated Wearable Sensors and Approved Devices

    Time frame: Through study completion, an average of 15 minutes.

    Signals from the approved medical devices will measure tissue mechanics, heart rate, respiration rate, blood flow, and pulse oxygenation measurements and these data will be compared to the signals from our sensors. The difference over time will be measured on a scale from a minimum of 0 and a maximum of 1, with 0 being the best outcome and representing the lowest difference between the sensing data from the different devices.

Study contacts

Contact information is provided by the study sponsor or research team.

Hannah L Weisbecker, BS

CONTACT

[email protected]

6786417484

Wubin Bai, PhD

CONTACT

[email protected]

9198439334

Sponsors and collaborators

Lead sponsor

University of North Carolina, Chapel Hill

Other

Collaborators

  • North Carolina Translational and Clinical Sciences Institute

Registry information

Official study title

Evaluation of Wearable Multi-modality Sensors for Monitoring Vital Signs

Important dates

Study start
2024
Primary completion
2026
Study completion
2026
First posted
May 31, 2022
Registry last updated
Apr 17, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.