The Role of Gadoxetate (Eovist) Enhanced CT in Evaluating Cholangiocarcinoma

The purpose of this project is to evaluate the role of gadoxetate (Eovist®) enhanced dual-energy CT in better evaluating perihilar cholangiocarcinoma. This pilot project aims to address a long-term pitfall in the imaging of cholangiocarcinomas, by providing higher resolution delineation of these often infiltrative tumors on single-source, Dual-Energy Spectral Multi Detector CT (MDCT), capitalizing on improved spatial resolution achievable with MDCT compared to MRI and at the same time producing a non-invasive CT cholangiogram to aid in accurate diagnosis and treatment planning of cholangiocarcinoma, particularly, the hilar variety.

Completed

Looking for future studies?

Notify Me

Key information

Age range

19 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Early Phase 1

Primary location

University of Alabama at Birmingham

Birmingham, Alabama, 35294, United States

About this study

The purpose of this project is to evaluate the role of gadoxetate (Eovist) enhanced dual-energy CT in better evaluating perihilar cholangiocarcinoma, by exploiting the combination of the physiologic behavior of gadoxetate in liver tissue combined with the advantageous mass attenuation coefficient of Gadolinium achievable through dual energy technique. This combination of unique CT imaging sensitivity, high resolution and differential enhancement potentially allows improved visualization and detection of tumor relative to enhancing surrounding hepatic parenchyma and ductal anatomy in the hepatobiliary phase, due to the biliary excretion of the agent.

Cholangiocarcinoma is a hepatic adenocarcinoma that arises from the bile duct epithelium and is the second most prevalent liver cancer after hepatocellular carcinoma. The hilar intrahepatic variety of cholangiocarcinoma can present as an infiltrative, exophytic, or polypoid lesion. Most extra-hepatic cholangiocarcinomas are infiltrative, causing a focal stricture of the bile duct and result in proximal biliary ductal dilatation.

While magnetic resonance (MR) cholangiography is diagnostic in the majority of patients with malignant hilar strictures, evaluation is limited by spatial resolution and in some patients, the inability to have an MRI scan. Standard Multi Detector CT (MDCT) using iodinated contrast agents, on the other hand, is limited in evaluation of cholangiocarcinomas, due to the lack of consistent enhancement of the tumor with iodinated contrast.

Single-source, Dual-Energy (SSDE) Spectral MDCT utilizes a single fast switching x-ray beam source to acquire near simultaneous data sets at two different photon energies during a single acquisition. Data is acquired at 80 kilovolt peak (kVp) and 140 kVp with image reconstruction achievable as a selectable monochromatic presentation over a range of 40 - 140 kiloelectron volt (keV), typically 70-78 keV for diagnostic image presentation. At lower tube voltage, the frequency of photoelectric interactions increases exponentially and is strongly dependent on the atomic number. Therefore, for substances with higher atomic number, such as iodine and gadolinium the increased frequency of photoelectric and k-edge interactions at low tube voltage substantially increases CT attenuation, thus improving contrast. Gadolinium is further unique with k-edge attenuation at approximately 53 keV, within the available monochromatic reconstruction range, thus allowing for significant greater detectability. Additional material decomposition technique allows for unique material presentation and analysis such as gadolinium/ water pair analysis with high spatial resolution.

Dual-Energy technology is limited by the types of contrast agents currently available, all based on Iodine. Gadoxetate (Eovist) is a relatively new Gadolinium based MRI contrast agent that is capable of producing not only standard appearing MRI images in the hepatic arterial and portal venous phases, but also provides an opportunity to better visualize the bile ducts and liver parenchyma as it is excreted by the liver into the biliary system during the hepatobiliary phase.

This pilot project aims to address a long-term pitfall in the imaging of cholangiocarcinomas, by providing higher resolution delineation of these often infiltrative tumors on single-source, Dual-Energy Spectral MDCT, capitalizing on improved spatial resolution achievable with MDCT compared to MRI and at the same time producing a non-invasive CT cholangiogram to aid in accurate diagnosis and treatment planning of cholangiocarcinoma, particularly, the hilar variety.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subjects will be adult (age 19 or older) with suspected cholangiocarcinoma of the liver.
  • Subject must be able to provide a written informed consent.
  • Subject will be scheduled for gadoxetate contrast enhanced MRI scan of the liver (obtained as part of usual clinical practice).

Exclusion criteria

  • Standard MRI safety screening criteria will be employed, and subject will be excluded if any contraindications to undergo MRI are met.
  • Subjects with metallic biliary stents or multiple peripancreatic surgical clips on abdominal MDCT will be excluded.
  • Subjects on hemodialysis or with glomerular filtration rate (GFR) less than 30 will be excluded.
  • Subjects will not be excluded on the basis of gender, race, ethnicity, or religion.
  • Subject may not be pregnant or lactating.

Treatment and study plan

CT scan

Drug

Gadoxetate (Eovist) enhanced dual energy CT

Other names: Dual Energy CT

Primary outcomes

  1. Number of Subjects Where Hilar Cholangiocarcinomas Could be Visualized Using Gadoxetate Disodium Enhanced Dual Energy CT

    Time frame: 24 hrs

    CT scans were assessed for tumor visualization after use of Gadoxetate disodium

Sponsors and collaborators

Lead sponsor

University of Alabama at Birmingham

Other

Collaborators

  • Society of Abdominal Radiology

Registry information

Official study title

The Role of Gadoxetate Enhanced Spectral Dual-Energy CT in Evaluating Hilar Cholangiocarcinoma

Important dates

Study start
2012
Primary completion
2014
Study completion
2014
First posted
Aug 28, 2012
Registry last updated
Jun 1, 2017

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.