Occlutech AFR Device
DeviceCatheter-guided transeptal placement of an AFR device following balloon atrial septostomy (BAS) -procedure.
NCT Number: NCT03022851
This study aims to investigate safety and efficacy of Occlutech® AFR device in patients with severe pulmonary hypertension (PH).
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Klinikum der Universität München, Munich, Bavaria, Germany
This study will enroll subjects with severe pulmonary hypertension until a maximum of 30 patients have undergone implantation with the Occlutech® AFR device. Enrolment will be devided in 2 phases.
Phase 1: At least 15 adult patients with age ≥ 18 years will be enrolled. Phase 2: Patients with age ≥ 6 years will be enrolled until a maximum of 30 patients is reached.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
10.2. Severe pulmonary hypertension as evident by echocardiography Echocardiographic: 10.2.1. RV larger than LV; 10.2.2. RA larger than LA; 10.2.3. atrial septum bulging into left atrium 10.2.4.ventricular septum bulging into the left ventricle 10.2.5.Reduced (below age-related normal mean value) TAPSE 10.3. Severe pulmonary hypertension as evident by CATH CATH-data: 10.3.1.Mean RA pressure (RAP) of > 10 and ≤ 20 mmHg; 10.3.2.Mean LA pressure (LAP) < 15 mmHg 10.3.3.Mean RAP > mean LAP; 10.3.4.Mean pulmonary arterial pressure >25 mm Hg 10.3.5. Echocardiographically demonstrated continuous right to left shunt following balloon aterial septostomy (BAS) and before AFR device implantation.
Exclusion criteria
Processes which interfere medically with invasive device implantation
might interfere with the implantation, might affect the patient's well-being thereafter or might interfere with the conduct and follow up within the Study is general.
Exclusion criteria
Catheter-guided transeptal placement of an AFR device following balloon atrial septostomy (BAS) -procedure.
Time frame: 0-3 month
To evaluate the safety and tolerability of the Occlutech® AFR device by assessing the incidence of SADEs between 3-12 months following implantation.
Time frame: 3-12 month
To evaluate the safety and tolerability of the Occlutech® AFR device by assessing the incidence of SADEs between 3-12 months following implantation.
Time frame: 0-12 month
The secondary efficacy endpoint will be determined via assessment by color-doppler echocardiography and angiography/fluoroscopy and requires both of:
Device placed in situ [as assessed by the investigator] Evidence of RIGHT TO LEFT shunt through the AFR device [as assessed by the investigator]
Time frame: 0-12 month
Occlutech International AB
Industry
Prospective, Non-randomized, Pilot Study to Assess Safety and Efficacy of a Novel Atrial Flow Regulator (AFR) in Patients With Pulmonary Hypertension
Acronym: AFR-Prophet
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00011648
Anemia, Anemia, Hemolytic
Washington D.C., District of Columbia, United States
View Trial DetailsNCT00678821
Cardiovascular Diseases, Hypertension
Bethesda, Maryland, United States
View Trial DetailsNCT03629340
Cardiovascular Diseases, Heart Diseases
San Francisco, California, United States
View Trial DetailsNCT03626688
Cardiovascular Diseases, Connective Tissue Diseases
Birmingham, Alabama, United States
View Trial Details