Healthcare workers measure heart rate, blood pressure, temperature, oxygen levels and breathing rate to monitor how unwell a patient is. All these apart from breathing rate are now normally measured by machines. But there still isn't a machine that does this well enough for breathing rate to be used in most places. The machines that do exist are either uncomfortable or don't work well on patients who are moving. Instead, a healthcare worker will count the number of breaths a patient takes. This needs staff time and isn't very accurate.
It is known that changes in breathing rate can happen any time. But healthcare systems normally only measure it every few hours because it takes time. Breathing rate could be monitored all the time, we might pick up people getting sick earlier and be able to treat them more quickly, which could save lives.
A team at the University of Southampton has made a small device, called a PneumoRator, that gets stuck to onto a person's chest. Once stuck there it can measure their breathing rate and store or send that information wirelessly. The device has been tested on healthy volunteers but has never been tested on patients in hospital.
In this study the team will put the device on patients having major operations. The investigators will record information already collected about patients during normal care. This includes their breathing rate using the best measurement we have, where a patient's breathing is measured by a gas they breathe out. The gas is carbon dioxide, and the measurement is called capnography. This way of measuring is only used in operating theatres and intensive care units but is a good way to check if the PneumoRator is accurate.
The investigators want to attach the PneumoRator to patient's chests before they go to sleep for their operation and leave it there for the first few days after their operation. This will let them see how the PneumoRator compares to capnography and manual breath counting. It will also let them see how the device works at different times in the patient's journey. The investigators will look at the time when patients are asleep, when breathing is controlled by a machine. Then when patients wake up investigators can measure with both capnography and the PneumoRator. Finally, when patients go to the high dependency ward, investigators will compare it against manual counting. The study team will also ask patients how they found wearing the device and any problems they found.
With this information the investigators hope to show the PenumoRator is accurate at measuring breathing rate and comfortable for patients. This will help them get the device approved for use in hospitals and other places where breathing rate needs to be measured accurately.
Interested in participating?
Request Info18 year and older
All sexes
Observational
Southampton, United Kingdom
Location status: Recruiting
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: From start of anaestheisa care until departure from PACU (Recovery)
Time frame: Post-operative Day 1
Time frame: Perioperatively
Time frame: Postoperative day 1-3
Measured using likert-scale, created specifically for this study. Higher score means more discomfort. Minimum score = 3, maximum score = 15. Questions below, (choices in brackets each rated from 1-5):
University Hospital Southampton NHS Foundation Trust
Other
Clinical Validation of the PneumoRator Respiratory Rate Sensor in a Perioperative Cohort
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07431021
Asthma Acute, Behavior
London, United Kingdom
View Trial DetailsNCT07391280
Cancer, Cardiovascular
Glasgow, United Kingdom
View Trial DetailsNCT05505110
C-Section, Microbiome
Nashville, Tennessee, United States
View Trial DetailsNCT06716463
Hypoventilation, Hypoxemic Respiratory Failure
Toronto, Ontario, Canada
View Trial Details