Stent assisted coiling with the Liberty Stent
DevicePatients are implanted with the Liberty Stent as an assist to embolic coiling of their wide-neck, saccular, intracranial aneurysms and follow for 12 months
NCT Number: NCT01636453
To assess the safety and effectiveness of the Penumbra Liberty Stent System as adjunctive treatment to embolic coils for wide-neck, saccular, intracranial aneurysms in the internal carotid artery (ICA). The Liberty Stent System is an implantable device comprised of a stent and delivery system designed as an adjunct to embolic coils in the treatment of wide-neck, saccular, intracranial aneurysms. It has three components: an implant, an introducer sheath and a delivery wire assembly. The implant component is made of superelastic and biocompatible nitinol tubular material. Patients presenting with wide-neck, saccular, intracranial aneurysms in the internal carotid artery (ICA) from the cavernous segment to the carotid terminus (including the paraclinoid, ophthalmic, hypophyseal and posterior communicating segments) will receive stent assisted coiling by the Penumbra Liberty Stent with any approved embolic coils currently on the market. Wide-neck aneurysms are defined by a neck ≥4mm or a dome-to-neck ratio <2. Each patient will be followed and assessed for 2, 6 and 12 months after enrollment.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Swedish Medical Center, Denver, Colorado, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patients are implanted with the Liberty Stent as an assist to embolic coiling of their wide-neck, saccular, intracranial aneurysms and follow for 12 months
Time frame: At 12 months post-implant
Complete aneurysmal obliteration is defined by the method of Raymond et al. (Class I) (Stroke 2001;32:1998-2004).
Time frame: At 12 months post-implant
Time frame: At 12 months post-implant
Defined as episodes of focal or global neurological dysfunction due to brain or retinal infarction in the same hemisphere of the target aneurysm with signs and symptoms that persist for 24 hours or longer. When appropriate, non contrast CT scans will be used to eliminate hemorrhagic strokes
Time frame: During the procedure
The number of participants with device-related Serious Adverse Events as a measure of safety of the procedure and device. The FDA definitions for Serious Adverse Events are used.
Time frame: During the procedure
Defined by the failure of the device to deploy or failure to correctly position the device over the aneurysm
Time frame: 12 months post-implant
Migration is defined as movement of the Liberty stent by more than 5 mm as documented by the 12 month angiogram when compared to its immediate post-implant position.
Time frame: At 12 months post-implant
Raymond Class I Occlusion grading defined as complete obliteration of the aneurysm at 12 months.
Time frame: At 12 months post-implant
Inclusive of subarachnoid, intraventricular or intraparenchymal hemorrhages (symptomatic or asymptomatic). Symptomatic is defined as a 4 point or more increase in the National Institutes of Health Stroke Scale (NIHSS) from baseline. The NIHSS ranges from 1 to 42, with higher scores indicating greater severity of stroke.
Time frame: At 12 months post-implant
The Modified Rankin Scale measures functional ability on a scale from 0-5, with 0 indicating no symptoms at all and 5 indicating severe disability.
Time frame: At 12 months post-implant
Time frame: At 12 months post-implant
Defined as any intervention after the completion of the initial stent assisted coiling procedure
Time frame: at 12 months post-implant
Device patency (stenosis) at 12 months
Time frame: At 12 months post-implant
Penumbra Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05774782
Aneurysm, Brain Diseases
Beijing, China
View Trial DetailsNCT06303063
Aneurysm, Brain Diseases
Beijing, China
View Trial DetailsNCT05945563
Aneurysm, Brain Diseases
Dallas, Texas, United States
View Trial DetailsNCT04380350
Aneurysm, Brain Diseases
Salzburg, Austria
View Trial Details