Samsung Medical Center, Sungkyunkwan University, School of Medicine
Seoul, 135-710, South Korea
NCT Number: NCT03358446
Evaluation for the range of smallest leg angulation with femoral artery and vein overlap with femoral central catheterization in pediatrics.
Looking for future studies?
Notify MeUp to 36 month
All sexes
Observational
Seoul, 135-710, South Korea
In pediatrics, femoral vein catheterization often overlaps with the femoral artery.
In this case, the risk of artery puncture is high, vein collapse when artery puncture 2nd, 3rd times exceeds the success rate of catheterization becomes low. In previous study, comparing 0, 30, and 60 degrees with frog leg position, there was a study that the overlap was the smallest at 60 degrees. A previous study was a simple frog leg position and a study in fragmented predetermined angles. On a continuous measurement, we planned the study under the assumption that there is a more definite range of optimal angulation.
Ultrasound probe in the state of Inguinal crease, we find a part without bifurcation of femoral artery and femoral vein in frog leg position(external rotation + flexion increase). Increase the leg angle and check the vein and arterie relations.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The optimal range of leg abduction was defined as the range without overlap in A group and the range presenting that the overlap was less-than half of the diameter of femoral vein in S group.
A1 angle defined the point that the femoral vein and artery started non-overlapping interval when increasing the angle of the leg in the A group and the A2 angle is defined the point that the femoral vein and artery ended non-overlapping interval.
B1 is the angle at which the overlap starts at the half of the femoral vein radius when increasing the angle of the leg in the S group, B2 is the angle at which overlap starts at half or more of the femoral vein radius again. In the range of B1 and B2 angles, they are overlapped by half or less of the femoral vein radius.
Time frame: Intraoperative ( after anesthesia induction)
The optimal range of leg abduction was defined as the range without overlap in A group and the range presenting that the overlap was less-than half of the diameter of femoral vein in S group.
Samsung Medical Center
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03712657
Complicated Appendicitis, Disease Attributes
Wuhan, Hubei, China
View Trial DetailsNCT06489951
Female Urogenital Diseases, Female Urogenital Diseases and Pregnancy Complications
Chongqing, Chongqing Municipality, China
View Trial DetailsNCT05590884
Body Indication, Central Nervous System Diseases
Cincinnati, Ohio, United States
View Trial DetailsNCT05762835
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Infant, Newborn, Diseases
Sacramento, California, United States
View Trial Details