oral appliance treatment
Devicemandibular advancement device to enlarge pharyngeal airway space to get rid of apnea and hypopnea events
NCT Number: NCT03665818
1. The purpose of this study is to detect the differences of carotid atherosclerosis severity between patients with or without OSAHS(Obstructive Sleep Apnea and Hypopnea Syndrome) in a cross-sectional study in a large sample. 2. Then a longitudinal control study is conducted to observe the progress of the carotid atherosclerosis by vascular ultrasonography and the occurrence of cerebrovascular events after the intervention of the oral appliance for treating OSAHS,and finally explore the feasibility of using oral appliance to treat OSAHS in primary prevention of ischemic stroke.
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
At timepoint of initial time, one month after oral appliance treatment, one and a half year after oral appliance treatment, the intervention group should accept PSG(Polysomnography) examination to monitor the treatment of OSAHS.
At timepoint of initial time, one month after oral appliance treatment, one and a half year after oral appliance treatment, the two groups should accept breath holding test to monitor the cerebral vascular reserve.
At timepoint of initial time, one and a half year after oral appliance treatment, the two groups should accept carotid vascular ultrasonography examination to monitor the progress of carotid atherosclerosis.
Cerebrovascular events and death are recorded from initial time. Statistics are done to detect the influence of treatment of OSAHS on carotid atherosclerosis.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
mandibular advancement device to enlarge pharyngeal airway space to get rid of apnea and hypopnea events
Time frame: initial time when patients are recruited
apnea and hypopnea times per hour
Time frame: one month after oral appliance treatment
apnea and hypopnea times per hour
Time frame: one and a half years after oral appliance treatment
apnea and hypopnea times per hour
Time frame: initial time when patients are recruited
longest apnea or hypopnea time
Time frame: one month after oral appliance treatment
longest apnea or hypopnea time
Time frame: one and a half years after oral appliance treatment
longest apnea or hypopnea time
Time frame: initial time when patients are recruited
Blood oxygen saturation less than 90% of the total monitoring time percentage
Time frame: one month after oral appliance treatment
Blood oxygen saturation less than 90% of the total monitoring time percentage
Time frame: one and a half years after oral appliance treatment
Blood oxygen saturation less than 90% of the total monitoring time percentage
Time frame: initial time when patients are recruited
blood lowest oxygen saturation during the whole night
Time frame: one month after oral appliance treatment
blood lowest oxygen saturation during the whole night
Time frame: one and a half years after oral appliance treatment
blood lowest oxygen saturation during the whole night
Time frame: initial time when patients are recruited
atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media
Time frame: one and a half years after oral appliance treatment
atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media
Time frame: initial time when patients are recruited
atherosclerosis plaque length is distance from the beginning to the end of a separate plaque
Time frame: one and a half years after oral appliance treatment
atherosclerosis plaque length is distance from the beginning to the end of a separate plaqu
Time frame: initial time when patients are recruited
atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media
Time frame: one and a half years after oral appliance treatment
atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media
Time frame: initial time when patients are recruited
atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media
Time frame: one and a half years after oral appliance treatment
atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media
Time frame: initial time when patients are recruited
atherosclerosis plaque length is distance from the beginning to the end of a separate plaque
Time frame: one and a half years after oral appliance treatment
atherosclerosis plaque length is distance from the beginning to the end of a separate plaque
Time frame: initial time when patients are recruited
atherosclerosis plaque length is distance from the beginning to the end of a separate plaque
Time frame: one and a half years after oral appliance treatment
atherosclerosis plaque length is distance from the beginning to the end of a separate plaque
Time frame: initial time when patients are recruited
breath holding index = (v2-v1)/v2*100/t. v2 is average velocity of middle cerebral artery after breath holding, v1 is average velocity of middle cerebral artery before breath holding, t is time for breath holding.
Time frame: one and a half years after oral appliance treatment
breath holding index = (v2-v1)/v2*100/t. v2 is average velocity of middle cerebral artery after breath holding, v1 is average velocity of middle cerebral artery before breath holding, t is time for breath holding.
Time frame: initial time when patients are recruited
the velocity of common carotid artery at the end of systolic period
Time frame: one and a half years after oral appliance treatment
the velocity of common carotid artery at the end of systolic period
Time frame: initial time when patients are recruited
the velocity of internal carotid artery at the end of systolic period
Time frame: one and a half years after oral appliance treatment
the velocity of internal carotid artery at the end of systolic period
Time frame: initial time when patients are recruited
the velocity of carotid bulb at the end of systolic period
Time frame: one and a half years after oral appliance treatment
the velocity of carotid bulb at the end of systolic period
Time frame: initial time when patients are recruited
the velocity of common carotid artery at the end of diastolic period
Time frame: one and a half years after oral appliance treatment
the velocity of common carotid artery at the end of diastolic period
Time frame: initial time when patients are recruited
the velocity of internal carotid artery at the end of diastolic period
Time frame: one and a half years after oral appliance treatment
the velocity of internal carotid artery at the end of diastolic period
Time frame: initial time when patients are recruited
the velocity of carotid bulb at the end of diastolic period
Time frame: one and a half years after oral appliance treatment
the velocity of carotid bulb at the end of diastolic period
Xuanwu Hospital, Beijing
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04399200
Apnea, Arterial Occlusive Diseases
Grenoble, France
View Trial DetailsNCT06283017
Apnea, Dyssomnias
Adelaide, South Australia, Australia
View Trial DetailsNCT06627127
Apnea, Dyssomnias
Wollongong, New South Wales, Australia
View Trial DetailsNCT06283030
Apnea, Dyssomnias
Nashville, Tennessee, United States
View Trial Details