Skip to main content
OpenTrials
Completed

NCT Number: NCT03496116

The Influence of Electronic (ECIG) Heater Resistance on ECIG Acute Effects

The purpose of this study is to measure the individual and combined influence of electronic cigarette (ECIG) heating element resistance and liquid nicotine concentration on ECIG acute effects. Thirty-two experienced ECIG users will complete four independent laboratory sessions that will differ by heater resistance (0.5 ohm or 1.5 ohm) and liquid nicotine concentration (3 or 8 mg/ml). Other factors such as voltage, liquid solvent ratio, and liquid flavor will be held constant. Plasma nicotine concentration, subjective effects, and puffing behavior will be recorded for each condition.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–55 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Virginia Commonwealth University

Richmond, Virginia, 23298, United States

About this study

Electronic cigarettes (ECIGs) are a popular and rapidly evolving class of products. ECIG users can manipulate several device features including liquid nicotine concentration (mg/ml) and heating element resistance (ohms). An emerging class of ECIG models includes "sub-Ohm" devices that employ low resistance heaters that are often used to achieve high device power. Some clinical laboratory data suggest that high power devices deliver nicotine to the user effectively, even when paired with a low liquid nicotine concentration. However, given that ECIG heater resistance and liquid nicotine concentration have not been manipulated in clinical laboratory studies, the influence of these factors on ECIG acute effects remain unclear. The purpose of this clinical laboratory study is to measure the influence of heater resistance and liquid nicotine concentration on ECIG acute effects. Participants will attend the lab for four experimental sessions where they use an ECIG. For each session, the participants will be randomly assigned (like the flip of a coin) to receive an ECIG with one of two different levels of heating coil resistance (which will determine overall device power) and one of two different liquid nicotine concentrations. The four sessions will begin at approximately the same time each day, will be separated by at least 48 hours, and will not occur more than two times per week. The primary hypotheses are that the low resistance heater paired with the 8 mg/ml liquid nicotine concentration, will result in greater nicotine delivery and subjective effect profiles, suggestive of higher abuse potential. Results from this study will further our understanding of the factors that influence the dependence potential of ECIGs and could inform future regulation of these devices.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Willing to provide informed consent, attend the lab and abstain from nicotine/tobacco as required, and use designated products according to study protocol
  • Experienced ECIG users (use ≥1 ml of ECIG solution daily, use ECIG solution with a nicotine concentration ≥3 mg/ml, and have used their ECIG for ≥3 months)
  • Urine cotinine test result ≥ 3

Exclusion criteria

  • History of organ-related diseases or current psychiatric condition
  • Regular use of prescription medication other than vitamins or birth control
  • Past month use of cocaine, opioids, benzodiazepines, or methamphetamine
  • Using marijuana greater than 10 days in the past 30 and/or alcohol greater than 25 days in the past 30 days
  • Pregnant or breastfeeding women
  • Weight less than 110 pounds
  • Daily use of >5 cigarettes or use of other tobacco products (i.e., hookah, cigars) >3 times a week

Treatment and study plan

ECIG Session

Other

Participants will complete four sessions using an e-cigarette, including a 10-puff product use bout followed by a 60-minute ad lib bout over an approximately 4-hour period. The study conditions for each session (i.e., heater resistance and nicotine combinations) will be Latin-square ordered.

Primary outcomes

  1. Cmax: Plasma nicotine concentration (ng/ml)

    Time frame: Six blood samples are collected at each of the 4 visits. During each session, blood samples are collected 90,100,160,185,205,225 minutes into the session which lasts approximately 4 hours.

Secondary outcomes

  1. Withdrawal suppression: Hughes-Hatsukami Withdrawal Scale

    Time frame: Collected six times at each of the 4 visits. During each session, questions are collected 90,100,160,185,205,225 minutes into the session which lasts approximately 4 hours.

    Contains 11 items. Administered on a computerized visual analogue scale that consists of a phrase centered on a horizontal line with "not at all" on the left and "extremely" on the right.. Responses range from 0-100.

  2. Withdrawal suppression: Direct effects of nicotine scale

    Time frame: Collected six times at each of the 4 visits. During each session, questions are collected 90,100,160,185,205,225 minutes into the session which lasts approximately 4 hours.

    Contains 9-items. Administered on a computerized visual analogue scale that consists of a phrase centered on a horizontal line with "not at all" on the left and "extremely" on the right.. Responses range from 0-100.

  3. Withdrawal suppression: Tiffany Drobes Questionnaire of Smoking Urges

    Time frame: Collected six times at each of the 4 visits. During each session, questions are collected 90,100,160,185,205,225 minutes into the session which lasts approximately 4 hours.

    Contains 10 items. Participants will be asked to rate each phrase on a 7-point scale ranging from 0 (Strongly disagree) to 7 (Strongly agree). The items from this scale will form two factors: Factor 1 (intention to smoke) and Factor 2 (anticipation of relief from abstinence symptoms).

  4. Withdrawal suppression: Direct effects of ECIG use scale

    Time frame: Collected six times at each of the 4 visits. During each session, questions are collected 90,100,160,185,205,225 minutes into the session which lasts approximately 4 hours.

    Contains 14-items. Administered on a computerized visual analogue scale that consists of a phrase centered on a horizontal line with "not at all" on the left and "extremely" on the right. Responses range from 0-100.

  5. Other subjective effects: General Labeled Magnitude Scale

    Time frame: Collected six times at each of the 4 visits. During each session, questions are collected 90,100,160,185,205,225 minutes into the session which lasts approximately 4 hours.

    Contains 4-items. This category-ratio scale contains seven semantic labels that increase in sensitivity including: "no sensation", "barely detectable", "weak", "moderate", "strong", "very strong", and "strongest imaginable sensation of any kind." Responses will be coded on a 0-100 scale.

  6. Other subjective effects: Labeled Hedonic Scale

    Time frame: Collected six times at each of the 4 visits. During each session, questions are collected 90,100,160,185,205,225 minutes into the session which lasts approximately 4 hours.

    Contains 4-items. This category-ratio scale contains ten semantic labels, intended to assess participant liking or disliking of sensations experienced in the general labeled magnitude scale.. Semantic labels include: "most liked sensation imaginable", "like extremely", "like very much", "like moderately", "like slightly", "dislike slightly", "dislike moderately", "dislike very much", "dislike extremely" and "most disliked sensation imaginable". Responses will be coded on a 0-100 scale.

  7. Puff Topography: puff duration

    Time frame: Collected twice at each of the 4 visits. During each session, puff duration is measured at 95 and 225 minutes.

    Puff duration is the measurement of the length of participant puffs in seconds during a 10-puff directed puffing bout (lasting 5-minutes) and during the 60-minute ad libitum bout where participants are instructed to puff as much or as little as they like on the ECIG.

  8. Puff Topography: puff volume

    Time frame: Collected twice at each of the 4 visits. During each session, puff duration is measured at 95 and 225 minutes.

    Puff volume is the measurement of the size of participant puffs in milliliters during a 10-puff directed puffing bout (lasting 5-minutes) and during the 60-minute ad libitum bout where participants are instructed to puff as much or as little as they like on the ECIG.

  9. Puff Topography: puff velocity

    Time frame: Collected twice at each of the 4 visits. During each session, puff duration is measured at 95 and 225 minutes.

    Puff velocity is the measurement of the speed of participant puffs in milliliters per second during a 10-puff directed puffing bout (lasting 5-minutes) and during the 60-minute ad libitum bout where participants are instructed to puff as much or as little as they like on the ECIG.

Sponsors and collaborators

Lead sponsor

Virginia Commonwealth University

Other

Registry information

Official study title

The Influence of Electronic Cigarette Heater Resistance on Nicotine Delivery, Heart Rate, Subjective Effects and Puff Topography

Important dates

Study start
2018
Primary completion
2018
Study completion
2018
First posted
Apr 12, 2018
Registry last updated
May 9, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.