Department of Ophthalmology, University Hospital of Alexandroupolis
Alexandroupoli, Evros, 68100, Greece
NCT Number: NCT05359380
Primary objective of this study is to identify the optimal task lighting conditions (in terms of light intensity and light temperature) for 10 activities of daily living (ADLs) that require near or intermediate vision acuity in a validated ADL simulation framework for a sample of patients who underwent presbyopic correction with bilateral multifocal intraocular lenses (IOLs) implantation, and to compare their capacity to perform ADLs (ADL scores) between three study groups (SG): SG1. patients implanted bilaterally with trifocal diffractive IOLs, SG2. patients implanted bilaterally with bifocal hybrid (diffractive-refractive) IOLs, SG3. patients implanted bilaterally with monofocal IOLs
Looking for future studies?
Notify Me18 year–85 year
All sexes
Observational
Alexandroupoli, Evros, 68100, Greece
Patients who underwent presbyopic correction with bilateral implantation of multifocal IOLs are supposed to have sufficient uncorrected vision capacity for ADLs that require near (ie. book reading) or intermediate (ie. reading in a computer screen) vision acuity. However, it is known that light intensity and light temperature has a great impact on near/intermediate vision capacity, but also patients that have been implanted with multifocal IOLs are most likely to present completely different lighting needs than patients with their own crystalline lenses.
Primary objective of this study is to identify the optimal task lighting conditions (in terms of light intensity and light temperature) for 10 ADLs that require near or intermediate vision acuity in a validated ADL simulation framework for a sample of patients who underwent presbyopic correction with bilateral multifocal IOLs implantation, and to compare their capacity to perform the ADLs (ADL scores) in 9 different lighting combinations (combinations of light intensity and light temperature) between three study groups: SG1. patients implanted bilaterally with trifocal diffractive IOLs, SG2. patients implanted bilaterally with bifocal hybrid (diffractive-refractive) IOLs, SG3. patients implanted bilaterally with monofocal IOLs
The study is conducted in an experimental facility in a hospital room with a dimension of 6.87 × 2.9 × 3 m (depth × width × height) and flat white surface walls (reflectance: 70%). Αn advanced light diffusion system has been installed, which consists of four linear LED luminaires producing low glare (unified glare rating (UGR) < 19). Light intensity (dimming / in foot candles - fc) and light temperature (white tuning / (in Kelvins - K) have been adjusted using the Casambi wireless control application (Casambi Technologies Oy Inc., Espoo, Finland), which uses integrated Bluetooth mesh technology and secures maximal uniformity at different user-defined lighting settings. The four LED luminaires have been mounted on the ceiling. The exact luminaire positioning and the amount of the provided luminous flux have been defined using the RELUX light simulation tool (version 2021.1.1.0) (Relux Informatik AG, Münchenstein, Switzerland) prior to the installation. The confirmation of illuminance and on-site adjustments have been confirmed with the Extech Lux Meter EA30 (Extech Instruments Corporation, Nashua, NH, United States). As regards photometric properties derived from lighting laboratory photometric measurements, the correlated color temperature (CCT) of the luminaires ranges between 2700 K and 6500 K, emitting a maximum luminous flux of 10,626 lm and 11,508 lm, respectively. The exact radiant flux P(λ) emitted from the selected light sources has been measured using a Konica Minolta CL-500A spectrum meter for the wavelength range of 380-780 nm using a step of 1 nm. The power of each luminaire is 106 W, resulting in luminous efficacy of 100.2 lm/W and 108.6 lm/W for 2700 K and 6500 K, respectively. The color rendering index (CRI) is 84. The wireless dimming control system enables dimming from 0% to 100% and vice versa.
The 9 lighting combinations (light intensity, light temperature) are the following:
3000 K - 25 fc, 3000 K - 50 fc, 3000 K - 75 fc / 4000 K - 25 fc, 4000 K - 50 fc, 4000 K - 75 fc / 6000 K - 25 fc, 6000 K - 50 fc, 6000 K - 75 fc
In specific, patients address the following ten ADLs:
Test-retest reliability will be assessed by calculating intraclass correlation coefficients (ICCs) for all ADLs at the nine combinations of light conditions in two different visits with an average 15-day time window to prevent memory effect.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
ADL performance
All study groups address the following 10 ADL tasks in 9 different combinations of light temperature and light intensity in order possible differences to be revealed among the study groups and light combinations:
The 9 light combinations are the following:
3000 K - 25 fc, 3000 K - 50 fc, 3000 K - 75 fc / 4000 K - 25 fc, 4000 K - 50 fc, 4000 K - 75 fc / 6000 K - 25 fc, 6000 K - 50 fc, 6000 K - 75 fc
Time frame: through study completion, an average of 6 months
Patient is required to find and read a specific entry in a regular phonebook catalog in the nine different combinations of light temperature and light intensity. A different entry is asked to be found in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to find and read three products from a typical supermarket receipt in the nine different combinations of light temperature and light intensity. Different products are asked to be found in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to read an excerpt of a predetermined length in a novel in the nine different combinations of light temperature and light intensity. A different excerpt of the same length is asked to be read in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to read a Short Message Service (SMS) on a cellular phone in the nine different combinations of light temperature and light intensity. A different SMS is asked to be read in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to find and read one specific entry on a cellular phone in the nine different combinations of light temperature and light intensity. Different entries are asked to be found in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to correctly read text of a predetermined length from a computer screen in the nine different combinations of light temperature and light intensity. Different texts of the same length are asked to be read in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to correctly read the expiration date printed on three typical eye dropper bottles in the nine different combinations of light temperature and light intensity. Different eye dropper bottles are given to be read in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to correctly read movie subtitles from a one-minute movie excerpt on a computer screen in the nine different combinations of light temperature and light intensity. Different movie excerpts are shown in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to find a specific key from a keychain that holds 10 keys and put it in the corresponding door keyhole in the nine different combinations of light temperature and light intensity. Different keychains are given in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Patient is required to select one among three screwdrivers and insert it in the appropriate screw among a variety of screw types in the nine different combinations of light temperature and light intensity. Different screwdrivers are given to be selected in each combination.
[scale's best value: 100, scale's worst value: 0]
Time frame: through study completion, an average of 6 months
Monocular and binocular UDVA of all groups is estimated using the Greek version of the Early Treatment Diabetic Retinopathy Study Chart at four meters distance
Time frame: through study completion, an average of 6 months
Monocular and binocular UIVA of all groups is estimated using web-based Democritus Digital Acuity Reading Test (wDDART)
Time frame: through study completion, an average of 6 months
Monocular and binocular UNVA of all groups is estimated using web-based Democritus Digital Acuity Reading Test (wDDART)
Time frame: through study completion, an average of 6 months
Vision-specific quality of life of all participants is evaluated with the Greek version of NEI VFQ-25, which is handed to the patients prior to their ADL assessment.
Time frame: through study completion, an average of 6 months
Patients are asked to choose the most preferable combination of light intensity and light temperature among the 9 different combinations for the most comfortable performance in ADLs
Democritus University of Thrace
Other
Evaluation of the Impact of Light Intensity and Light Temperature on the Efficacy of Presbyopic Corrections With Bilateral Implantation of Multifocal Intraocular Lenses in a Series of Activities of Daily Living
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05005624
Daily Activities, Eye Diseases
Alexandroupoli, Evros, Greece
View Trial DetailsNCT05735990
Cataract, Eye Diseases
Almería, Spain
View Trial DetailsNCT05431868
Behavior, Cataract
Beijing, Beijing Municipality, China
View Trial DetailsNCT04618224
Eye Diseases, Low Vision
Alexandroupoli, Evros, Greece
View Trial Details