Skip to main content
OpenTrials
Completed

NCT Number: NCT05359380

The Impact of Light Conditions on the Efficacy of Multifocal Intraocular Lens Implantation in Activities of Daily Living

Primary objective of this study is to identify the optimal task lighting conditions (in terms of light intensity and light temperature) for 10 activities of daily living (ADLs) that require near or intermediate vision acuity in a validated ADL simulation framework for a sample of patients who underwent presbyopic correction with bilateral multifocal intraocular lenses (IOLs) implantation, and to compare their capacity to perform ADLs (ADL scores) between three study groups (SG): SG1. patients implanted bilaterally with trifocal diffractive IOLs, SG2. patients implanted bilaterally with bifocal hybrid (diffractive-refractive) IOLs, SG3. patients implanted bilaterally with monofocal IOLs

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–85 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Department of Ophthalmology, University Hospital of Alexandroupolis

Alexandroupoli, Evros, 68100, Greece

About this study

Patients who underwent presbyopic correction with bilateral implantation of multifocal IOLs are supposed to have sufficient uncorrected vision capacity for ADLs that require near (ie. book reading) or intermediate (ie. reading in a computer screen) vision acuity. However, it is known that light intensity and light temperature has a great impact on near/intermediate vision capacity, but also patients that have been implanted with multifocal IOLs are most likely to present completely different lighting needs than patients with their own crystalline lenses.

Primary objective of this study is to identify the optimal task lighting conditions (in terms of light intensity and light temperature) for 10 ADLs that require near or intermediate vision acuity in a validated ADL simulation framework for a sample of patients who underwent presbyopic correction with bilateral multifocal IOLs implantation, and to compare their capacity to perform the ADLs (ADL scores) in 9 different lighting combinations (combinations of light intensity and light temperature) between three study groups: SG1. patients implanted bilaterally with trifocal diffractive IOLs, SG2. patients implanted bilaterally with bifocal hybrid (diffractive-refractive) IOLs, SG3. patients implanted bilaterally with monofocal IOLs

The study is conducted in an experimental facility in a hospital room with a dimension of 6.87 × 2.9 × 3 m (depth × width × height) and flat white surface walls (reflectance: 70%). Αn advanced light diffusion system has been installed, which consists of four linear LED luminaires producing low glare (unified glare rating (UGR) < 19). Light intensity (dimming / in foot candles - fc) and light temperature (white tuning / (in Kelvins - K) have been adjusted using the Casambi wireless control application (Casambi Technologies Oy Inc., Espoo, Finland), which uses integrated Bluetooth mesh technology and secures maximal uniformity at different user-defined lighting settings. The four LED luminaires have been mounted on the ceiling. The exact luminaire positioning and the amount of the provided luminous flux have been defined using the RELUX light simulation tool (version 2021.1.1.0) (Relux Informatik AG, Münchenstein, Switzerland) prior to the installation. The confirmation of illuminance and on-site adjustments have been confirmed with the Extech Lux Meter EA30 (Extech Instruments Corporation, Nashua, NH, United States). As regards photometric properties derived from lighting laboratory photometric measurements, the correlated color temperature (CCT) of the luminaires ranges between 2700 K and 6500 K, emitting a maximum luminous flux of 10,626 lm and 11,508 lm, respectively. The exact radiant flux P(λ) emitted from the selected light sources has been measured using a Konica Minolta CL-500A spectrum meter for the wavelength range of 380-780 nm using a step of 1 nm. The power of each luminaire is 106 W, resulting in luminous efficacy of 100.2 lm/W and 108.6 lm/W for 2700 K and 6500 K, respectively. The color rendering index (CRI) is 84. The wireless dimming control system enables dimming from 0% to 100% and vice versa.

The 9 lighting combinations (light intensity, light temperature) are the following:

3000 K - 25 fc, 3000 K - 50 fc, 3000 K - 75 fc / 4000 K - 25 fc, 4000 K - 50 fc, 4000 K - 75 fc / 6000 K - 25 fc, 6000 K - 50 fc, 6000 K - 75 fc

In specific, patients address the following ten ADLs:

  • Phone Book Search (PBS), 2. Supermarket receipt (SupRe), 3. Book reading (BR), 4. Cellular message (CM), 5. Cellular entry search (CES), 6. Reading computer screen (RCS), 7. Drops bottle reading (DR), 8. Subtitles reading (SubRe), 9. Open door test (ODT), and, 10. Screwdriver test (ST).

Test-retest reliability will be assessed by calculating intraclass correlation coefficients (ICCs) for all ADLs at the nine combinations of light conditions in two different visits with an average 15-day time window to prevent memory effect.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age older than 18 years old
  • Diagnosis of senile cataract either stage 2 or 3 of the Lens Opacities Classification System III (LOCS-3) grading scale - Patients underwent phacoemulsification and bilateral implantation of IOLs [trifocal diffractive, bifocal hybrid (diffractive - refractive) or monofocal]
  • Fluency in written and verbal Greek language
  • No severe cognitive impairment

Exclusion criteria

  • Αstigmatism >1.00 diopters
  • Glaucoma
  • Intraocular pressure-lowering medications
  • Corneal pathology
  • Fundus pathology
  • Diabetes mellitus
  • Autoimmune diseases
  • Former incisional eye surgery
  • Posterior capsule rupture or lens misalignment
  • Neurological, psychiatric or mental diseases that interfere with visual acuity and reading process
  • Inability to understand the objectives of the study

Treatment and study plan

ADL performance

Other

ADL performance

All study groups address the following 10 ADL tasks in 9 different combinations of light temperature and light intensity in order possible differences to be revealed among the study groups and light combinations:

  • Phone Book Search (PBS), 2. Supermarket receipt (SupRe), 3. Book reading (BR), 4. Cellular message (CM), 5. Cellular entry search (CES), 6. Reading computer screen (RCS), 7. Drops bottle reading (DR), 8. Subtitles reading (SubRe), 9. Open door test (ODT), and, 10. Screwdriver test (ST).

The 9 light combinations are the following:

3000 K - 25 fc, 3000 K - 50 fc, 3000 K - 75 fc / 4000 K - 25 fc, 4000 K - 50 fc, 4000 K - 75 fc / 6000 K - 25 fc, 6000 K - 50 fc, 6000 K - 75 fc

Primary outcomes

  1. Phone Book Search (PBS) score

    Time frame: through study completion, an average of 6 months

    Patient is required to find and read a specific entry in a regular phonebook catalog in the nine different combinations of light temperature and light intensity. A different entry is asked to be found in each combination.

    [scale's best value: 100, scale's worst value: 0]

  2. Supermarket Receipt (SupRe) score

    Time frame: through study completion, an average of 6 months

    Patient is required to find and read three products from a typical supermarket receipt in the nine different combinations of light temperature and light intensity. Different products are asked to be found in each combination.

    [scale's best value: 100, scale's worst value: 0]

  3. Book Reading (BR) score

    Time frame: through study completion, an average of 6 months

    Patient is required to read an excerpt of a predetermined length in a novel in the nine different combinations of light temperature and light intensity. A different excerpt of the same length is asked to be read in each combination.

    [scale's best value: 100, scale's worst value: 0]

  4. Cellular message (CM) score

    Time frame: through study completion, an average of 6 months

    Patient is required to read a Short Message Service (SMS) on a cellular phone in the nine different combinations of light temperature and light intensity. A different SMS is asked to be read in each combination.

    [scale's best value: 100, scale's worst value: 0]

  5. Cellular Entry Search (CES) score

    Time frame: through study completion, an average of 6 months

    Patient is required to find and read one specific entry on a cellular phone in the nine different combinations of light temperature and light intensity. Different entries are asked to be found in each combination.

    [scale's best value: 100, scale's worst value: 0]

  6. Reading Computer Screen (RCS) score

    Time frame: through study completion, an average of 6 months

    Patient is required to correctly read text of a predetermined length from a computer screen in the nine different combinations of light temperature and light intensity. Different texts of the same length are asked to be read in each combination.

    [scale's best value: 100, scale's worst value: 0]

  7. Drops bottle Reading (DR) score

    Time frame: through study completion, an average of 6 months

    Patient is required to correctly read the expiration date printed on three typical eye dropper bottles in the nine different combinations of light temperature and light intensity. Different eye dropper bottles are given to be read in each combination.

    [scale's best value: 100, scale's worst value: 0]

  8. Subtitles Reading (SubRe) score

    Time frame: through study completion, an average of 6 months

    Patient is required to correctly read movie subtitles from a one-minute movie excerpt on a computer screen in the nine different combinations of light temperature and light intensity. Different movie excerpts are shown in each combination.

    [scale's best value: 100, scale's worst value: 0]

  9. Open Door Test (ODT) score

    Time frame: through study completion, an average of 6 months

    Patient is required to find a specific key from a keychain that holds 10 keys and put it in the corresponding door keyhole in the nine different combinations of light temperature and light intensity. Different keychains are given in each combination.

    [scale's best value: 100, scale's worst value: 0]

  10. Screwdriver Test (ST) score

    Time frame: through study completion, an average of 6 months

    Patient is required to select one among three screwdrivers and insert it in the appropriate screw among a variety of screw types in the nine different combinations of light temperature and light intensity. Different screwdrivers are given to be selected in each combination.

    [scale's best value: 100, scale's worst value: 0]

Secondary outcomes

  1. Uncorrected Distance Visual Acuity (UDVA)

    Time frame: through study completion, an average of 6 months

    Monocular and binocular UDVA of all groups is estimated using the Greek version of the Early Treatment Diabetic Retinopathy Study Chart at four meters distance

  2. Uncorrected Intermediate Visual Acuity (UIVA)

    Time frame: through study completion, an average of 6 months

    Monocular and binocular UIVA of all groups is estimated using web-based Democritus Digital Acuity Reading Test (wDDART)

  3. Uncorrected Near Visual Acuity (UNVA)

    Time frame: through study completion, an average of 6 months

    Monocular and binocular UNVA of all groups is estimated using web-based Democritus Digital Acuity Reading Test (wDDART)

  4. 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) score

    Time frame: through study completion, an average of 6 months

    Vision-specific quality of life of all participants is evaluated with the Greek version of NEI VFQ-25, which is handed to the patients prior to their ADL assessment.

  5. Subjective preference of lighting combination

    Time frame: through study completion, an average of 6 months

    Patients are asked to choose the most preferable combination of light intensity and light temperature among the 9 different combinations for the most comfortable performance in ADLs

Sponsors and collaborators

Lead sponsor

Democritus University of Thrace

Other

Registry information

Official study title

Evaluation of the Impact of Light Intensity and Light Temperature on the Efficacy of Presbyopic Corrections With Bilateral Implantation of Multifocal Intraocular Lenses in a Series of Activities of Daily Living

Important dates

Study start
2021
Primary completion
2022
Study completion
2022
First posted
May 3, 2022
Registry last updated
Apr 24, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.