Intensive Care Unit
Warrington, WA5 1QG, United Kingdom
NCT Number: NCT07606690
Many patients lose muscle due to being unwell in an intensive care unit. This muscle loss can lead to weakness of the arms and legs when they leave the unit, and when they go home. For many years investigators have measured the size of these arm and leg muscles using an ultrasound machine, to take a picture of the muscles.
It is also known that patients who are on a ventilator (or "breathing machine") often have problems swallowing when the breathing tube is removed from their mouth. This may be because the muscles of swallowing may also shrink. One of these muscles sits under the jaw and can be measured with ultrasound - the method has been shown to be accurate and reliable in awake volunteers, but these volunteers are usually sat upright in a chair with their mouth closed.
Before it can be assed whether these muscles get smaller, it is needed to assess whether the chosen method is suitable in patients on a ventilator; these patients are lying in bed, and their mouths are open slightly due to the breathing tube.
Proposed Method
This investigation will measure the size of a muscle under the jaw (called the geniohyoid muscle) in patients who are sedated and have a breathing tube in their mouth connected to a ventilator.
Using a normal hospital ultrasound machine, one researcher will place the ultrasound probe under the patient's jaw. When the researcher is happy the probe is in the right place, they will take a picture of the muscle and measure its size and thickness. After a short break, the researcher will repeat this process. After a second short break, another researcher who did not watch the first researcher will also place the probe under the jaw and take a picture of the muscle.
These measurements can be used to to answer the following questions:
1. How many patients scanned produced images that could be measured? 2. How consistent are the measurements if one person measures the same muscle twice? 3. If two people measure the same muscle, do their measurements agree with each other?
The patients will be under sedation when they take part in the study. Because of this, they cannot consent to take part in the study. The patient's next of kin or carer would advise on whether the patient would want to take part. When the patient is awake and has the breathing tube removed, the research team would ask them to sign a consent form to use their data.
Trial opening soon.
Get Notified18 year and older
All sexes
Observational
Warrington, WA5 1QG, United Kingdom
Introduction
Many patients who are mechanically ventilated due to critical illness have difficulty in swallowing after the endotracheal tube is removed, a phenomenon known as Post Extubation Dsyphagia (PED). Although multifactorial, atrophy of the swallowing muscles is a potential cause.
Ultrasound is a commonly used investigative modality for the measurement of muscles in critically unwell patients. Measurements can be performed repeatedly over time to track changes in muscle size during the course of a patient's admission. In critically unwell patients, much of the research is focussed on muscles of the limbs and trunk. The muscles of swallowing have been measured using ultrasound, but in awake patients adopting an optimal seated position. Critically unwell patients are bedbound, and the endotracheal tube leaves their mouth in an open position. Before embarking on a study using ultrasound to attempt to track changes in muscle size in the muscles of swallowing, the investigators first wish to assess if such a method is both feasible and reliable.
Methods
Critically unwell patients who are sedated and mechanically ventilated will be recruited into the study after discussion with a patient's personal consultee. The geniohyoid (GH) muscle will be scanned in both the coronal and sagittal planes. The patient will be scanned three times. Twice by one assessor, and once by a second assessor. Cross sectional areas (CSA) of GH will be measured at a later time using image processing software (ImageJ, NIH, USA). Echogenicity, a measurement of the brightness of muscle on ultrasound, will also be assessed.
Results
The primary outcome is to obtain the proportion of patients whose images from ultrasound can provide satisfactory measurement data, in each plane. Furthermore, we will assess the repeatability of each measurement by calculating the intra-rater agreement, and the inter-rater agreement to assess agreement between assessors. An estimate of the mean CSA in each plane will be calculated.
Conclusions
This preliminary data will give us an estimate of the proportion of patients who can provide satisfactory images of GH, in preparation for a larger study assessing longitudinal changes in CSA. Further, the study will give data on both the inter- and intra-rather agreement of the method.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: Day 1 (patients are only on the day of the ultrasound)
To obtain an estimate for the proportion of patients in which satisfactory images can be measured, in both measured planes (coronal and sagittal views). An "unsatisfactory" image is due to either the investigator being unable to adequately visualise the GH muscle with the probe (e.g. due to subcutaneous fat, difficult patient positioning, or when an image has been obtained, the offline CSA measurement cannot be performed due to inadequate visualisation of the muscle's fascial border. In addition, the co-efficient of variance of the three images taken must be less than 5%.
Time frame: Day 1 - patients are only in the study on the day of the ultrasound scan
To obtain an estimate for the proportion of patients in which satisfactory images can be measured, in the sagittal plane. An "unsatisfactory" image is due to either the investigator being unable to adequately visualise the GH muscle with the probe (e.g. due to subcutaneous fat, difficult patient positioning, or when an image has been obtained, the offline CSA measurement cannot be performed due to inadequate visualisation of the muscle's fascial border. In addition, the co-efficient of variance of the three images taken must be less than 5%.
Time frame: Day 1
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the coronal plane. After a short break, a second set of 3 images (set B) will be taken. Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and B, and calculating the intra-class correlation co-efficient for consistency.
Time frame: Day 1
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the sagittal plane. After a short break, a second set of 3 images (set B) will be taken. Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and B, and calculating the intra-class correlation co-efficient for consistency.
Time frame: Day 1
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the coronal plane. After a short break, investigator B will take a second set of 3 images (set C) Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and C, and calculating the intra-class correlation co-efficient for agreement.
Time frame: Day 1
In this outcome, investigator A will take 3 images (set A) of the geniohyoid muscle in the coronal plane. After a short break, investigator B will take a second set of 3 images (set C) Intra-rater agreement will be assessed by comparing mean and standard deviation of both set A and C, and calculating the intra-class correlation co-efficient for agreement.
Time frame: Day 1
Investigator A will have taken 2 sets of 3 images (sets A and B) of the geniohyoid muscle in the sagittal plane. Echogenicity will be measured offline using appropriate imaging software (Image J, NIH) and compared by mean and standard deviation, and by intra-class correlation coefficient for consistency.
Time frame: Day 1
Investigator A will have taken 2 sets of 3 images (sets A and B) of the geniohyoid muscle in the sagittal plane, and investigator B will take set of 3 images (set C). Echogenicity will be measured offline using appropriate imaging software (Image J, NIH) and compared by mean and standard deviation, and by intra-class correlation coefficient for absolute agreement.
Warrington Hospital
Other
Assessing the Feasibility and Reliability of an Ultrasound-based Method of Measuring the Geniohyoid Muscle in Mechanically Ventilated Patients - an Observational Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07714564
Hypoxemic Respiratory Failure, Mechanical Ventilation
Rome, Italy
View Trial DetailsNCT07710066
Agnosia, Confusion
View Trial DetailsNCT07709364
Cognition, Critical Care Nursing
Cambridge, Cambridgeshire, United Kingdom
View Trial DetailsNCT07701850
Dyspnea, Dyspnea During Mechanical Ventilation
Boston, Massachusetts, United States
View Trial Details