NCT Number: NCT02271048
Purpose
- The investigators aim to evaluate the feasibility of remote interpretation for ultrasound images using a smartphone based realtime image transmission system.
Methods
A total of 100 echocardiography examinations; 50 showed the ejection fraction above 50% and remaining 50 cases showed the ejection fraction under 50%, and 100 abdominal ultrasound images; 50 had signs of acute appendicitis and the other 50 had no findings of appendicitis will be consecutively selected. The 12 raters review these original images using an LCD monitor of the ultrasound machine and also an iPhone which is connected to the ultrasound machine via remote image transmission system (CubeView, Alpinion medical system, Seoul, Korea), evaluating left ventricular systolic function (for echocardiography) by measuring the ejection fraction and grading the probability of presence of acute appendicitis on each examination by a five Likert scale.
The sensitivity and specificity between two devices will be compared and the diagnostic performance between two devices will be also compared. The image quality between two devices will be measured using the double stimulation impairment scale (DSIS)
Looking for future studies?
Notify Me33 year–45 year
Male
Interventional
Not applicable
Guri-si, GyeongGido, 471-701, South Korea
The 12 raters are randomly divided into two groups
The raters in group one review the echocardiographies examinations numbered from one to 50 using LCD monitor of ultrasound machine and review the remaining 50 examinations numbered from 51 to 100 using iPhone with CubeView at their first visit The other group firstly review echocardiography numbered from one to 50 using iPhone with CubeView and 51 to 100 with the LCD monitor.
They visit twice with an interval of four weeks and review the echocardiography examinations using revered devices at each session. They also review abdominal ultrasound images on the same plan as reviewing echocardiography.
When they review the echocardiography, the raters measure the ejection fraction by visual estimation (1=obviously normal EF, 2 = probably normal EF, 3 = unsure, 4 = probably reduced EF, 5 = obviously reduced EF). In cate of d the abdominal ultrasound, they are instructed to rate the likelihood of the presence or absence of appendicitis in each case using a five-Likert scale (1 = obvious no appendicitis, 2 = unlikely appendicitis, 3 = unsure, 4 = likely appendicitis, 5 = obvious appendicitis).
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The reviewers interpreted the ultrasonography images on the smartphone transmitted from the ultrasound machine in real time
Other names: Smartphone (A1530, iPhone 5S, USA)
Time frame: within one day
Dorfman-Berbaum-Metz method with RSCORE and semi-parametric estimation of ROC indices by using the DMB-MRMC software (version 2.3, available at http://perception.radiology.uiowa.edu)
Hanyang University
Other
The Feasibility and Effectiveness Study for Clinical Application of Realtime Tele-ultrasonography Using the Smartphone
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02591602
Cost-Benefit Analysis, Frail Elderly
View Trial DetailsNCT06571981
Digestive System Diseases, Hepatitis
Lausanne, Canton of Vaud, Switzerland
View Trial Details