Transpedicular Instrumentation
ProcedureTranspedicular screw placement and instrumentation
NCT Number: NCT03398915
In a multinational prospective study, preoperative, intraoperative, perioperative and follow-up data on patients receiving thoracolumbar pedicle screw placement for degenerative disease or infections or tumors will be collected. The three arms consist of robot-guided (RG), navigated (NV), or freehand (FH) screw insertion.
This study is active but is not currently recruiting participants.
18 year and older
All sexes
Observational
Medical University of Innsbruck, Innsbruck, Austria
Introduction A decade ago, minimally invasive surgery (MIS) was considered a promising development in spine surgery, yet the value of the pioneering technologies was questionable. With the growing number of experienced MIS surgeons, the influx of evidence in favour of MIS is rapidly increasing. This makes a compelling argument towards MIS offering distinct clinical benefits over open approaches in terms of blood loss, length of stay, rehabilitation, cost-effectiveness and perioperative patient comfort. Due to the limited or inexistent line-of-sight in MIS procedures, surgeons need to rely on imaging, navigation, and guidance technologies to operate in a safe and efficient manner. Therefore, a plethora of new and ever improving navigational systems have been developed. These systems allow a consistent level of safety and accuracy, on par with results achieved by very experienced free hand surgeons, with a reasonably short learning curve. Computer-based navigation systems were first introduced to spine surgery in 1995 and while they have been long established as standards in certain cranial procedures, they have not been similarly adopted in spine surgery.
Designed to overcome some of the limitations of navigation-based technologies, robot-guided surgery has become commercially available to surgeons worldwide, like SpineAssist® (Mazor Robotics Ltd. Caesarea, Israel) and the recently launched ROSA™ Spine (Zimmer-Biomet, Warsaw, Indiana, USA). These systems are rapidly challenging the gold standards. SpineAssist®, and its upgraded version, the Renaissance®, provides a stable drilling platform and restricts the surgeon's natural full range of motion to 2 degrees of freedom (up/down motion and yaw in the cannula). The system's guidance unit moves into the trajectory based on exact preoperative planning of pedicle screws, while accounting for changes in intervertebral relationships such as due to distraction, cage insertion or changes between the supine patient position in the preoperative CT and the prone patient on the operating table. Published evidence on robot-guided screw placement has demonstrated high levels of accuracy with most reports ranging around 98% of screws placed within the pedicle or with a cortical encroachment of less than 2 mm.4 Although the reliability and accuracy of robot-guided spine surgery have been established, the actual benefits for the patient in terms of clinical outcomes and revision surgeries remain unknown. We have recently conducted cohort studies that showed some evidence that robotic guidance lowers the rate of intraoperative screw revisions and implant related reoperations compared to free hand procedures, while achieving comparable clinical outcomes. We now want to assess these factors, among others, on a higher level of evidence. We aim to conduct a prospective, multicenter, multinational controlled trial comparing clinical and patient reported outcomes of robotic guided (RG) pedicle screw placement vs. navigated (NV) vs. free hand (FH) pedicle screw placement using pooled data from three centers.
Study Design The European Robotic Spinal Instrumentation (EUROSPIN) study is a prospective, international, multicentre, pragmatic, open-label, non-randomized controlled trial comparing the effectiveness of three techniques for pedicle screw instrumentation, namely RG, NV (CT-, O-Arm, or 3DFL-based), and FH. Following the baseline evaluation, patients will receive one of the three treatments, and will subsequently be followed up for 24 months (Figure 1). The primary analysis will be conducted using the 12-month data.
Sample Size Calculation It was determined that, to detect an intergroup difference of 5% in the primary endpoint, 205 patients are required per group to achieve a power of 1 - beta = 0.8 at alpha = 0.05. The incidence rates were based on the published literature, with an approximated incidence rate of the primary endpoint of 0% for the intervention and 5% for the control group. Because the study protocol is in line with the normal clinical follow-up of most centers, a low dropout rate is expected. This led to a minimum total sample size of 615 patients.
Monitoring An epidemiologist from the sponsor institution will organize an initiation monitor visit at every participating center before starting recruitment. This monitor visit will check whether all study staff are properly trained and the delegation of tasks are well documented (complete Investigator Site File, training and delegation logs). An additional audit will be carried out at 6 months after initiation of recruitment to check whether source documentation and eCRF documentation is similar. Throughout the entire study additional queries by the monitor are send to the investigator in the data capturing system to ensure proper data capturing.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Transpedicular screw placement and instrumentation
Time frame: 12 months
We defined the primary endpoint as required revision surgery for a malpositioned or loosened pedicle screw within the first postoperative year.
Time frame: Intraoperative
Revision or redirection of a placed screw during the same general anesthesia session
Time frame: Intraoperative
Duration of Surgery in minutes
Time frame: Through hospital stay (From admission to discharge of the hospital stay in which the primary surgery was carried out)
Length of Hospital Stay in days (Defined as from admission to discharge, during the hospital stay in which the primary surgery was carried out)
Time frame: Intraoperative
Radiation Dose as DAP (Dose Area Product, cGy cm2)
Time frame: Intraoperative
Estimated Blood Loss (ml)
Time frame: Through hospital stay (From admission to discharge of the hospital stay in which the primary surgery was carried out)
Need for blood transfusion during the hospital stay (Defined as from admission to discharge, during the hospital stay in which the primary surgery was carried out)
Time frame: 0 weeks
Intraoperative Complications
Time frame: 6 weeks
Postoperative Complications
Time frame: 2 years
EQ-5D-3L (Health-related quality of life) EuroQOL-five dimensions 3-level version measures health-related quality of life.
The scale is subdivided into an index, ranging from 0 to 1 and normalized to population-specific values, and a "thermometer" or visual analogue scale, ranging from 0 to 100.
The two subscores are not combined towards a single score. Higher values represent a better health-related quality of life in both subscores.
Time frame: 2 years
Numeric Rating Scale (NRS) of back pain severity The scale ranges from 0 to 10. Only integers are available to choose from. Higher values represent a higher amount of pain. There are no subscales.
Time frame: 2 years
Numeric Rating Scale (NRS) of leg pain severity The scale ranges from 0 to 10. Only integers are available to choose from. Higher values represent a higher amount of pain. There are no subscales.
Time frame: 2 years
Oswestry Disability Index (ODI) for functional impairment
Time frame: 2 years
Frequency of use of analgetics (daily/weekly/not regularly)
Time frame: 2 years
Satisfaction with symptoms (satisfied/neutral/dissatisfied)
Time frame: 2 years
Smoking status (active/ceased/never)
Time frame: 2 years
Working status (able to work/unable to work)
Time frame: 2 years
Return to work (number of weeks/not yet)
Time frame: 2 weeks
Overall rate of reoperations
Marc Schröder
Other
The European Robotic Spinal Instrumentation (EUROSPIN) Study: A European Prospective Multicenter Multinational Pragmatic Trial on Robot-guided Versus Navigated Versus Freehand Pedicle Screw Fixation
Acronym: EUROSPIN
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03956537
Bone Diseases, Central Nervous System Diseases
Sande, Germany
View Trial DetailsNCT04489394
Bone Diseases, Cervical Spondylosis
Koblenz, Germany
View Trial DetailsNCT00549913
Bone Diseases, Degenerative Disc Disease
New York, United States
View Trial DetailsNCT01829997
Bone Diseases, Degenerative Disc Disease
New York, United States
View Trial Details