Respiratory exercise devices can be grouped as respiratory muscle training (RMT) devices and incentive spirometers (IS). IS can improve pulmonary ventilation using visual feedback but cannot increase respiratory muscle strength. RMT devices strengthen the respiratory muscles by their resistance mechanisms but they cannot provide visual feedback. It has been stated that RMT increases exercise performance in healthy individuals. RMT devices usually allow only one of inspiratory muscle training or expiratory muscle training. The need to acquire 2 devices for combined training increases the cost. It is seen that the RMT devices available in Turkey do not allow combined training and a significant part of them do not offer sufficient loading range.
The aims of the project are; to develop a multifunctional individualized respiratory exercise device originating in Turkey, and to analyze the clinical effects of an individualized respiratory exercise device on pulmonary function, respiratory muscle strength, and functional capacity in healthy individuals. The device to be developed in this project will be the first multifunctional respiratory exercise device originated in Turkey. The device will have the clinical features of IS and RMT devices and can be individualized according to the desired purpose. With the same device, the individual will be able to both improve the ventilation of the lungs like the IS and strengthen the respiratory muscles in the direction of inspiration and/or expiration with wide loading intervals.
A total of 46 healthy individuals will be included in the study. The healthy individuals included in the study will be randomly divided into two groups experimental group (n=23) and control group (n=23). The individuals in the experimental group will be trained with an individualized respiratory exercise device for 5 days a week for 8 weeks. The individuals in the control group will be trained with Threshold® IMT + Threshold™ PEP training for 5 days a week for 8 weeks. In both groups, pulmonary function, respiratory muscle strength, and functional capacity will be assessed before and after the 8 weeks of training.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Istanbul, Turkey (Türkiye)
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The Individualized Respiratory Exercise device will include both inspiratory muscle training, expiratory muscle training, and intensive spirometer features.
The Threshold® IMT device allows inspiratory muscle training and the Threshold™ PEP device allows expiratory muscle training.
Time frame: 8 weeks
Maximal Inspiratory Pressure will be measured in accordance with ATS/ERS criteria using an electronic, mobile, (MicroRPM, Micro Medical; UK) intraoral pressure measuring device. Three measurements will be repeated for each maneuver and the highest value recorded as cmH2O.
Time frame: 8 weeks
Maximal Expiratory Pressure will be measured in accordance with ATS/ERS criteria using an electronic, mobile, (MicroRPM, Micro Medical; UK) intraoral pressure measuring device. Three measurements will be repeated for each maneuver and the highest value recorded as cmH2O.
Time frame: 8 weeks
Forced Vital Capacity will be measured before six-minute walk test according to the guideline of ERS.
Time frame: 8 weeks
Forced Expiratory Volume in 1 second will be measured before six-minute walk test according to the guideline of ERS.
Time frame: 8 weeks
Peak Expiratory Flow will be measured before six-minute walk test according to the guideline of ERS.
Time frame: 8 weeks
Forced Expiratory Flow 25-75% will be measured before six-minute walk test according to the guideline of ERS.
Time frame: 8 weeks
The 6-minute Walk Test will be performed with Spiropalm 6 DYT (Cosmed, Spiropalm 6MWT) according to ATS guidelines. Walking distance, minute ventilation, respiratory rate, inspiratory capacity and breathing reserve will be recorded.
Time frame: 8 weeks
A 5-point Likert scale will be used to question the convenience of use of the devices used. Scoring will be determined as 1- "very difficult to use", 5- "very easy to use".
Biruni University
Other
Development of an Individualized Respiratory Exercise Device Originated in Turkey and Investigation of Its Clinical Effects on Healthy Individuals
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT06702423
Healthy
London, United Kingdom
View Trial DetailsNCT07223164
Healthy
Irvine, California, United States
View Trial DetailsNCT05595902
Healthy
Kadıköy, Istanbul, Turkey (Türkiye)
View Trial Details