İnonu University Medicine Faculty Turgut ozal Medical Center
Malatya, 44100, Turkey (Türkiye)
NCT Number: NCT07134933
The high incidence of breast cancer is increasing the need for oncologic breast surgery. The optimal acute postoperative pain management after breast surgery is not yet clear. The erector spinae plane block (ESPB) is a newer and may be potentially safer alternative other regional analgesia techniques. We will investigate the effectiveness of ESP for managing acute pain after breast cancer surgery. Patients will randomise to receive either ESP block (Group1)or no ESP block (Group II). The primary outcome is postoperative pain scores used Visual Analog Scale (VAS), and the secondary outcomes include intraoperative opioid consumption postoperative total opioid consumption and patient satisfaction.
Looking for future studies?
Notify Me18 year–65 year
Female
Interventional
Not applicable
Malatya, 44100, Turkey (Türkiye)
Anesthesia induction was achieved with propofol (2-3 mg kg-1), fentanyl (2 mcg kg-1), and rocuronium (0.6 mg kg-1). Anesthesia was maintained with Total intravenous anesthesia (TIVA) used remifentanil (0.25-0.5 mcg kg-1 min-1) and propofol (150 mcg kg-1 min-1). During maintenance, a fresh gas flow of 3 L with a mixture of 50% oxygen and 50% air was used. The BIS value was kept between 30-50.
Patients were divided into two groups according to a computer-based simple randomization method. Those who received a preoperative ESP block at the T4 vertebra level under ultrasound guidance were designated as Group I, while those who underwent surgery without the block were designated as Group II.
The ESP block was performed unilaterally in the direction of the surgery by the same anesthetist. Blocks were performed using an Esaote ultrasound device (Esaote My Lab 6 US machine, Florence, Italy), a multifrequency convex probe (1-8 MHz), and a 22-gauge, 50 mm facet needle (B. Braun Sonoplex, Melsungen, Germany) The block needle was placed at the level of the T4 spinal process using the in-plane approach, approximately 3 cm lateral to the T4 spinous process in the parasagittal plane. After visualizing the transverse process with the in-plane approach, the 50 mm facet needle (B. Braun Sonoplex, Melsungen, Germany) was inserted through the skin, and a test dose of 1 ml of 0.9% NaCl was injected between the fascia of the trapezius, rhomboid, and erector spinae muscles and the transverse vertebral process to confirm the location. A total of 20 ml of 0.5% bupivacaine was used as a local anesthetic. The cranial and caudal spread of the local anesthetic was monitored.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The ESP block was performed unilaterally in the direction of the surgery by the same anesthetist. Blocks were performed using an Esaote ultrasound device (Esaote My Lab 6 US machine, Florence, Italy), a multifrequency convex probe (1-8 MHz), and a 22-gauge, 50 mm facet needle (B. Braun Sonoplex, Melsungen, Germany). The block needle was placed at the level of the T4 spinal process using the in-plane approach, approximately 3 cm lateral to the T4 spinous process in the parasagittal plane. After visualizing the transverse process with the in-plane approach, the 50 mm facet needle (B. Braun Sonoplex, Melsungen, Germany) was inserted through the skin, and a test dose of 1 ml of 0.9% NaCl was injected between the fascia of the trapezius, rhomboid, and erector spinae muscles and the transverse vertebral process to confirm the location. A total of 20 ml of 0.5% bupivacaine was used as a local anesthetic.
Time frame: From beginning of anesthesia to finished the surgery
The primary aim of our study was to compare perioperative remifentanil consumption between Group I patients who received a preoperative ESP block and Group II patients who underwent surgery without the block.
Time frame: from the end of the surgery to 24 hours of postoperative
After extubation, a patient-controlled analgesia device containing morphine (0.5 mg/ml, 1 mg bolus, 8-minute lockout interval, maximum dose of 6 mg in 1 hour) was installed. The amount of morphine consumed in the postoperative 24 hours was measured.
Time frame: from the end of the surgery to 24 hours of postoperative
Postoperative pain assessment was conducted using the Visual Analog Scale (VAS), where 0 indicates no pain and 10 indicates unbearable pain) at rest and during movement at the 5, 15, 30, and 60 minutes, as well as at 2, 4, 6, 8, 16, and 24 hours post-surgery.
Time frame: at the 24th postoperative hour
a four-point patient satisfaction score (1: poor, 2: fair, 3: good, 4: excellent) were evaluated by an anesthetist who was unaware of the study groups.
Inonu University
Other
The Effects of Erector Spinae Plane Block on Pain Scores and Patient Experience in Unilateral Breast Cancer Surgery: A Prospective, Randomized Clinical Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07509957
Erector Spinae Plane Block, Inguinal Hernia Unilateral
Sanliurfa, Eyyübiye, Turkey (Türkiye)
View Trial DetailsNCT07101198
Erector Spinae Plane Block, Hemorrhage
Ankara, Turkey (Türkiye)
View Trial DetailsNCT05083832
Erector Spinae Plane Block, Neurologic Manifestations
Keçiören, Ankara, Turkey (Türkiye)
View Trial DetailsNCT06233617
Bone Diseases, Erector Spinae Plane Block
Poznan, Poznań, Poland
View Trial Details