Peripheral intravenous cannulation (PIVC) is one of the most common interventions in medical practice. Venous dilatation is helpful for successful PIV placement. Several techniques include hot pack application, tourniquet, massaging, and tapping over the vein to increase vein caliber described in the literature. However, none of them has been rigorously studied. Therefore, there is still no 'best practice' on how to effect vein dilation in a standard way.
This study aims to investigate the effect of standardized tapping on venous dilatation with a massage device compared to manual non-standardized tapping and define a standard tapping technique using a device.
In this study, the investigators also aim to investigate the effect of tourniquet application with and without vein tapping effect on peripheral vein caliber as determined by ultrasound measurement.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Gainesville, Florida, 32601, United States
PIVC is one of the most common medical interventions in daily practice. Even though it seems like it should be an easy procedure, PIVC can be challenging.
Venous dilatation optimizes conditions for successful vein cannulation. Several techniques are described to affect venodilation, but none of them are standardized because they are done manually, and there will be individual variations among clinicians.
Tapping over the vein has been reported as an effective method. It has been hypothesized that tapping affects vein vaso-nervorum activation and local histamine release. Tapping or massage over the cannulation site is readily applied in busy medical practice, with a third of nurses using tapping or massage to promote venodilation. Tapping and massage are effective methods of vasodilatation to make the vein more prominent for venipuncture, with tapping more effective than massage (Ichimura et al.) There are limited data concerning the effect of tapping in PIVC and its standardization. In the current literature, there is no standard technique on how tapping should be performed.
Specific Aims:
The investigators expect to learn to what degree a tourniquet increases peripheral vein size and to what degree that is augmented by tapping.
Research Plan:
This is a prospective non-randomized, controlled, non-invasive intervention study.
The investigators will visually and also with surface ultrasound inspect the upper extremity. The investigators will not get blood tests or X-rays for study purposes. The investigators will measure the venous diameter of a vein or veins on the back of the hand and deeper within the forearm and in the antecubital fossa using ultrasound. The investigators will use a survey including participant's demographics (age, gender, handedness, smoking history)
The investigators will use a portable ultrasound device (Butterfly iQ+, Butterfly Network, Inc., CT, USA) connected to an iPad to record ultrasound images (as pictures) and measure the diameter and cross-section area of the various veins. The investigators will take vein measurements from the dorsal hand, cubital, and mid-forearm regions. The investigators will take the measurements from the midline of the antecubital, volar side of the forearm, and dorsal hand regions. The investigators will put masking tapes on the skin as a reference point to make all the measurements from the same plane."
Then the investigators will determine the midpoint of the forearm, the antecubital site, and the volar wrist crease. The midpoint of this line will be the mid-forearm vein measurement site. The investigators will use superficial dorsal hand veins of the dorsal metacarpal region for the dorsal hand vein measurements. During the baseline measurements, the investigators will get the best image with ultrasound and then mark the skin to get all the measurements from the same cross-sectional area and place water-resistant tape with a scale.
The investigators will not use ultrasound gel or direct ultrasound probe application to the skin to prevent any possible ultrasound transducer-related venous compression. Instead, the investigators will sufficiently submerge the hand, forearm, and elbow in a fresh room temperature water-filled basin to allow precise vein caliber measurements with an ultrasound probe without any probe contact with the skin. This technique provides high-quality ultrasound images of superficial and deep veins.
The investigators will use a standard adult blood pressure cuff applied to the mid-upper arm statically inflated to 60mmHg to serve as a tourniquet.
The investigators will measure these parameters:
The investigators will make the measurements four times for each vein and participant:
The investigators will take photos of the ultrasound vein visualizations and measure the diameter and cross-sectional area. This will have no PHI attached to the ultrasound images.
The investigators will take photos of the skin using a calibration ruler to assess the dilation of the visible veins externally. These photos will not reveal the subject's face or any personally identifiable images or information. After all study procedures are complete on the initial arm, study procedures will be repeated on the opposite arm.
Primary investigators will be responsible for collecting the data.
The investigators will not use the name or identifiable data when entering the data into the software. Rather than that, the investigators will code the participants (E.g., A01, B02). This data will be stored only in the departmental password-protected encrypted share drive. The survey and paperwork, including any participant data, will be stored at the locked drawers in investigators' offices
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The investigators will apply a pressure cuff tourniquet inflated to 60 mmHg
The investigators will apply tapping directly over the vein manually to increase the vein dimension.
The investigators will apply tapping directly over the vein with a massage device to increase the vein dimension.
Time frame: 2 hours
The primary outcome is to measure the vein diameters after manual and device tapping and detect the change from baseline in vein diameters.
Time frame: 2 hours
Secondary outcome is to measure the vein diameters before and after tourniquet application and detect the change from baseline in vein diameters.
University of Florida
Other
Acronym: Tapping
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07006038
Catheter Complications, Catheterization, Peripheral
Izmir, Turkey (Türkiye)
View Trial DetailsNCT06851585
Catheterization, Catheterization, Peripheral
Poitiers, France
View Trial DetailsNCT04499638
Cardiovascular Diseases, Catheter-Related Infections
Barcelona, Spain
View Trial DetailsNCT06562829
Catheterization, Peripheral
Wuhan, Hubei, China
View Trial Details