University Hospital for Active Treatmnet in Endocrinology "Acad Ivan Penchev" EAD, Medical University of Sofia
Sofia, 1431, Bulgaria
NCT Number: NCT06974201
Managing insulin dosing for diabetes, particularly for those with type 1 diabetes mellitus, is a complex process that requires precision. Insulin bolus calculators are designed to help patients calculate their insulin needs based on variables such as carbohydrate intake, blood glucose levels, and insulin sensitivity. However, to ensure these tools are safe and effective, clinical trials are essential. The primary purpose of this trial is to assess the safety and efficacy of the bolus calculator - Diabetes M in providing accurate insulin dosing and preventing the risk of hypoglycemia and hyperglycemia, which can lead to severe complications. The clinical trial is critical to ensure patient's safety and build confidence in the use of the bolus insulin calculator in real-world settings. Insulin dosing errors, whether too high or too low, can lead to serious health risks, including hypoglycemia, hyperglycemia, and long-term diabetes complications. By conducting a controlled study, the trial will evaluate how well the bolus calculator performs in preventing these risks, comparing its recommendations to standard practices. This will help determine whether the calculator can consistently improve blood glucose management while minimizing human error in insulin dosing decisions. Finally, regulatory approval from bodies like the Food and Drug Administration (FDA) requires clear evidence of safety and efficacy. The data from this clinical trial will not only support regulatory submissions but also demonstrate the bolus calculator's clinical utility in improving outcomes like glycemic control and patient compliance. By empowering patients to make more informed dosing decisions and reducing the complexity of diabetes management, this trial could pave the way for broader adoption of this technology and ultimately improve the quality of life for patients with type 1 diabetes mellitus.
This study is active but is not currently recruiting participants.
Notify Me18 year–75 year
All sexes
Interventional
Not applicable
Sofia, 1431, Bulgaria
The primary objective of this study is to compare the effect of Diabetes M application use versus conventional bolus calculation (bolus wizard calculation in continuous subcutateous insulin infusion (CSII) or determined insulin:carb ratio (ICR) calculation in multiple daily injections regimen (MDI)) on glycaemic control, measured by time in range (TIR) in percentage defined as time spent in blood glucose levels between 3.9-10.0 mmol/l, in patients with type 1 diabetes on MDI or CSII.
The secondary objectives of this study are: 1) to compare the risk of hypoglycaemic episodes or time below range or time above range (TBR) in percentage, defined as time spent in blood glucose levels between 3.5-3.9 mmol/l level 1 and < 3.5 mmol/l level 2, in patients with type 1 diabetes on MDI or CSII using Diabetes M application versus conventional bolus calculation (bolus wizard calculation in CSII or determined ICR calculation in MDI); 2) to compare the risk of hyperglycaemic episodes or time above range (TAR) in percentage, defined as time spent in blood glucose levels between 10.0-13.0 mmol/l high and >13.0 mmol/l very high, in patients with type 1 diabetes on MDI or CSII using Diabetes M application versus conventional bolus calculation (bolus wizard calculation in CSII or determined ICR calculation in MDI); and 3) to compare time in tight range (TITR) in percentage, defined as time spent in blood glucose levels between 3.9-7.8 mmol/l in patients with type 1 diabetes on MDI or CSII using Diabetes M application versus conventional bolus calculation (bolus wizard calculation in CSII or determined ICR calculation in MDI).
Trial design This is a 4-week, open-label, non-randomized, single-armed, one-centre, proof of concept clinical trial. All subjects enrolled in the trial will be followed-up for 2-weeks on their usual treatment and then Diabetes M app will be applied. There is a 2-week screening period followed by enrolment visit (V1). At V1 venuos blood samples will be taken for laboratory tests all participants from all participants. Then there is a 2-week follow-up period on usual treatment ending with visit 2 (V2) when CGM data for the period will be downloaded and Diabetes M application will be installed. All individual parameters for the participants will be filled in the application and the participants will be instructed in details on how to use the application. Then there is a 2-week treatment period using Diabetes M application ending with visit 3 (V3) when CGM data for the period will be downloaded. Total trial duration for the individual subject will be approximately 6 weeks. The trial population will consist of subjects with type 1 diabetes treating with MDI or CSII and using continuous glucose monitoring (CGM).
Subject and trial completion Approximately 40 subjects will be screened in order to achieve 30 subjects to be assigned. The number of subjects expected to complete the trial will be 27 subjects (calculated 10% drop-off). Subjects will be followed for the planned duration of the trial.
Trial period completion for a subject is defined as when the enrolled subject has completed the final scheduled visit 'end of trial', visit 3. Date of trial completion is the date the subject completed the final scheduled visit, as mentioned above.
Treatment period completion for a subject is defined as when the subject has received the required treatment and attended the end of treatment visit 3.
Scientific rationale for trial design The treatment duration of the trial is 4 weeks, including 2 weeks on conventional bolus calculation and 2 weeks on Diabetes M app. A 2-week treatment duration is comparable to trials conducted with a previously approved device, which will serve as a predicator in the current study, and will provide robust data for the evaluation of efficacy and safety parameters. This open-label, non-randomized, single-armed, one-centre, proof of concept clinical trial design has the poor to accurately assess the effect and safety of Diabetes M application as an alternative bolus calculator in subjects with type 1 diabetes on MDI or CSII. The trial includes a screening visit to assess the subject's eligibility. After enrollment visit, there are 2 visits scheduled. Visit 2 is scheduled 2 weeks after enrolment for switching from conventional treatment to Diabetes M app installation and use. An end of trial visit 3 for efficacy and safety assessments is scheduled 2 weeks after visit 2.
The trial population will consist of subjects with type 1 diabetes on treatment with MDI or CSII using CGM. Patients with type 1 diabetes represent a clinically relevant high-risk population and it is highly likely to benefit from the use of such an application.
Prospective approval of protocol deviations to recruitment and enrolment criteria, also known as protocol waivers or exemptions, is not permitted.
Full guide for using the Diabetes:M mobile app, can be accessed at
The following auxiliary supplies will be provided by investigators:
Only supplies provided by investigators must be used for the administration of the trial product.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Diabetes related
Diabetes:M Bolus Calculator is an application for precise bolus insulin dose. Full guide for using the Diabetes:M mobile app, can be accessed at
Step-by-step instructions for bolus calculation via Diabetes:M app:
Diabetes:M Bolus Calculator is an application for precise bolus insulin dose. Full guide for using the Diabetes:M mobile app, can be accessed at
Step-by-step instructions for bolus calculation via Diabetes:M app:
Time frame: From enrollment to the end of treatment at 4 weeks.
The primary outcome measure is defined as a change in time in range (3.9-10 mmol/l) for glucose between the two estimated periods: the first period without using Diabetes M application for bolus insulin calculation and the second period with using Diabetes M application for bolus insulin calculation.
Time frame: From enrollment to the end of treatment at 4 weeks.
The secondary outcome measure is defined as a change in time below range (<3.9 mmol/l) for glucose between the two estimated periods: the first period without using Diabetes M application for bolus insulin calculation and the second period with using Diabetes M application for bolus insulin calculation.
Time frame: From enrollment to the end of treatment at 4 weeks.
The secondary outcome measure is defined as a change in time above range (>10.0 mmol/l) for glucose between the two estimated periods: the first period without using Diabetes M application for bolus insulin calculation and the second period with using Diabetes M application for bolus insulin calculation.
Time frame: From enrollment to the end of treatment at 4 weeks.
The secondary outcome measure is defined as a change in time in tight range (3.9-7.8 mmol/l) for glucose between the two estimated periods: the first period without using Diabetes M application for bolus insulin calculation and the second period with using Diabetes M application for bolus insulin calculation.
Medical University of Sofia
Other
An Open Label Study to Determine the Effect of Diabetes M Application Use Versus Conventional Bolus Calculation in Patients With Type 1 Diabetes Mellitus on MDI or CSII
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06390371
Autoimmune Diseases, Diabetes Mellitus
Kansas City, Missouri, United States
View Trial DetailsNCT07673523
Autoimmune Diseases, Diabetes Mellitus
Ankara, Turkey (Türkiye)
View Trial DetailsNCT06111586
Autoimmune Diseases, Diabetes Mellitus
San Francisco, California, United States
View Trial DetailsNCT03899402
Autoimmune Diseases, Diabetes Mellitus
Williamsville, New York, United States
View Trial Details