When implantable cardiac defibrillators are implanted (ICDs), the defibrillation threshold (DFT), of the amount of energy required to effectively terminate life-threatening arrhythmias is determined. The device is then programmed to discharge a larger amount of energy in order to provide a safety margin. In some patients, the DFT is so high, that an adequate safety margin is not programmable. Placement of a defibrillation lead in the azygos vein has been found to be helpful in these patients. This goal of this trial is to attempt to quantify the average reduction in the DFT (if any) that results from the addition of the azygos lead.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
St Louis, Missouri, 63110, United States
Patients undergoing placement of an ICD for the primary or secondary prevention of sudden cardiac death will be asked to participate. Patients will undergo implantation of a standard right ventricular ICD lead at the time of ICD implantation. In addition, patient will receive another high voltage ICD lead placed in the azygos vein as has been previously described in the literature (1). After sedating the patient, the DFT will be determined using a binary search algorithm. This consists of testing the device at a given output for the first shock after inducing ventricular fibrillation (VF). Should the shock fail, external defibrillation will be attempted, as is the standard method for performing DFT testing. As per the standard method of DFT testing, VF will be induced a second time, with the shock strength dependent on the success of the first shock. If the first shock was unsuccessful, the second will be at a higher output. If the first shock was successful, the second will be at a lower output. A third shock will then be delivered, based on the success or failure of the preceding shock to define the DFT. Of note, as the device can be programmed to give multiple shocks for one episode, VF will not necessarily need to be induced each time. For example, VF could be induced, and the device programmed to give a 20 Joule (J) shock followed by a 23J shock if not successful, thus limiting the number of VF inductions required. DFT testing will be done using both the standard configuration of high voltage leads as well as using the azygos lead. We hypothesize that using the azygos lead will result in a lower DFT.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Addition of an azygos vein defibrillation coil instead of a standard SVC coil.
Other names: Medtronic 6937A Lead
Time frame: During the course of the implant procedure and testing
Defibrillation threshold will be estimated by repeat defibrillation testing using an azygos coil and using an SVC coil (and compared).
The outcome measure quoted below is the mean DFT using the azygos coil vs. the mean DFT using the standard configuration.
Washington University School of Medicine
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03446651
Cardiovascular Diseases, Heart Diseases
New Haven, Connecticut, United States
View Trial DetailsNCT05806606
Behavior, Cardiovascular Diseases
Hong Kong
View Trial DetailsNCT06847438
Cardiovascular Diseases, Heart Diseases
Atlanta, Georgia, United States
View Trial DetailsNCT07721909
Cardiovascular Diseases, Heart Diseases
Muscat, Oman
View Trial Details