The Drift-Reduction for Improved FFR Using Fiberoptic Technology (DRIFT) Study

The primary objective of this study is to assess the accuracy, efficacy, and durability of the OpSens Medical OptoWire Deux pressure wire in the assessment of angiographically intermediate proximal left anterior descending coronary artery (LAD) stenoses in clinical practice.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

New York Presbyterian Hospital/Columbia University Medical Center, New York, United States

Loading trial locations.

About this study

This study is designed as a prospective, observational in nature, multi-center, single-arm, clinical registry to estimate the ischemic burden of angiographically intermediate proximal LAD stenosis in clinical practice using the OpSens Medical OptoWire Deux FFR system. Subjects with stable angina or unstable angina who are found to have an intermediate proximal LAD stenosis on coronary angiography with anatomy amenable to PCI and underwent physiological lesion assessment with the OptoWire Deux pressure wire and OCT as part of their routine procedures using standard of care techniques will be enrolled. Patients meeting enrollment criteria will be offered the opportunity to enroll in this observational registry post-procedure. All patients enrolled in this study are expected to be evaluated and treated using a standard of care technique. This study will enroll a total of 60 patients at Columbia University Medical Center and St. Francis Hospital.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or female subjects, >18 years of age.
  • Patients with stable angina, unstable angina or non-ST segment elevation myocardial infarction (if the LAD lesion is the non-culprit lesion) and in whom an intermediate proximal LAD de novo stenosis (30-80%) with TIMI flow 3 has been identified on angiography. Note: Patients with multi-vessel disease can be enrolled.
  • Patients have had fractional flow reserve (FFR) and optical coherence tomography (OCT) of the LAD with the OpSens FFR system as part of their routine evaluation as standard of care procedure.
  • Provides written, informed consent and HIPAA consent to use the data in a clinical study.

Exclusion criteria

(General exclusion criteria)

  • Patients presented with NSTEMI with the LAD involved as the culprit lesion
  • Any ST-elevation myocardial infarction within the past 30 days.
  • Hemodynamic instability requiring vasopressor or mechanical circulatory support.
  • Prior heart transplant.
  • Known left ventricular ejection fraction ≤40%.
  • LAD supplying akinetic or severely hypokinetic territories if already known based on prior imaging.
  • Patient is enrolled in another clinical study that may impact the results of this study.
  • FFR not acquired per instructions for the OpSens Wire.
  • LAD Lesion not assessed with OCT.

(Angiographic exclusion criteria)

  • Thrombolysis in Myocardial Infarction (TIMI) grade 2 or lower at baseline angiography.
  • Target lesion involves left main (stenosis >50%).
  • Previous percutaneous coronary intervention (PCI) with stent in LAD or left main trunk.
  • Presence of chronic total occlusion in any vessel.
  • Presence of a side branch≥2.75 mm with ≥70% stenosis in the LAD.
  • Bifurcation lesion that resulted in the stent implantation of a side branch.

Treatment and study plan

OpSens Medical OptoWire

Device

The OptoWire is FDA approved to measure pressure in coronary vessels during diagnostic angiography and coronary interventions.

The OptoWire Deux pressure wire (OpSens Medical, Quebec, Canada) is a novel technology utilizing optical coherence technology to enhance FFR assessment of the coronaries.

Other names: OpSens Medical OptoWire Deux FFR System

FFR

Procedure

A guide wire-based procedure that can accurately measure blood pressure and flow through a specific part of the coronary artery. FFR is done through a standard diagnostic catheter at the time of a coronary angiogram (a.k.a. cardiac catheterization).

Other names: Fractional Flow Reserve

Primary outcomes

  1. Percentage of Recordings of Significant Drift in Pre and Post-PCI

    Time frame: During procedure, approximately less than an hour

    The rate of significant drift is defined as FFR <0.97 or >1.03 with the in the pre-percutaneous coronary intervention (PCI) FFR recording using the OpSens OptoWire Deux pressure wire system. FFR is calculated by measuring the ratio between pressure distal to a stenosis and pressure proximally to stenosis using specialized pressure-measuring guidewires during maximal hyperemia.

Sponsors and collaborators

Lead sponsor

Columbia University

Other

Registry information

Official study title

The Drift-Reduction for Improved Fractional Flow Reserve (FFR) Using Fiberoptic Technology (DRIFT) Study

Acronym: OPSENS

Important dates

Study start
2018
Primary completion
2019
Study completion
2019
First posted
Feb 21, 2019
Registry last updated
Jun 11, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.