Skip to main content
OpenTrials
Completed

NCT Number: NCT02806570

The CorCinch - Functional Mitral Valve Regurgitation (FMR) Study

This is a multi-center, non-randomized, prospective Early Feasibility Study to evaluate the AccuCinch® Ventricular Restoration System in patients with symptomatic heart failure and concomitant functional mitral regurgitation that have stable symptoms on guideline-directed medical therapy

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Emory University, Atlanta, Georgia, United States

Loading trial locations.

About this study

Device name changed from AccuCinch® Ventricular Repair System to AccuCinch® Ventricular Restoration System, FDA Approval Date 08Aug2020

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Study patient is at least 18-years old
  • Severity of FMR: ≥ Moderate (i.e., 2+, according to Stone et al Clinical Trial Design Principles and Endpoint Definitions for Transcatheter Mitral Valve Repair and Replacement: Part 1: Clinical Trial Design Principles. A Consensus Document from the Mitral Valve Academic Research Consortium11; and 2003 ASE Guidelines for grading mitral regurgitation10)
  • Ejection Fraction: ≥20 to ≤60%
  • Symptom Status: NYHA II-IV (i.e., ambulatory)
  • Treatment and compliance with optimal guideline directed medical therapy for heart failure for at least 1 month
  • Surgical risk: Subject is eligible for cardiac surgery (specific risk score or comorbidities should demonstrate high risk features, as determined by the Heart Team)
  • Completion of all qualifying diagnostic and functional tests and agrees to comply with study follow-up schedule

Exclusion criteria

  • Patients with significant organic mitral valve pathology (e.g. myxomatous degeneration, mitral valve prolapse or flail leaflets)
  • Myocardial infarction or any percutaneous cardiovascular intervention, cardiovascular surgery, or carotid surgery within 30 days
  • Prior surgical, transcatheter, or percutaneous mitral valve intervention
  • Untreated clinically significant coronary artery disease (CAD) requiring revascularization
  • Hemodynamic instability: Hypotension (systolic pressure <90 mmHg) or requirement for inotropic support or mechanical hemodynamic support
  • Any planned cardiac surgery or interventions within the next 6 months (including right heart procedures)
  • NYHA class IV (i.e., non-ambulatory) or American College of Cardiology (ACC)/American Heart Association (AHA) Stage D heart failure
  • Fixed pulmonary artery systolic pressure >70 mmHg
  • Severe tricuspid regurgitation (per ASE guidelines and graded by the Echo Core Lab)
  • Modified Rankin Scale ≥ 4 disability
  • Hypertrophic cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis, or any other structural heart disease causing heart failure other than dilated cardiomyopathy of either ischemic or non-ischemic etiology.
  • Anatomical pathology/constraints preventing appropriate access/implant of the AccuCinch® Ventricular Restoration System (e.g., femoral arteries will not support a 20F system)
  • Renal insufficiency (i.e., eGFR of <30ml/min/1.73m2; Stage 4 or 5 CKD)
  • Moderate or severe aortic valve stenosis or regurgitation or aortic valve prosthesis
  • Fluoroscopic or echocardiographic evidence of severe aortic arch calcification, mobile aortic atheroma, intracardiac mass, thrombus or vegetation
  • Active bacterial endocarditis

Treatment and study plan

Mitral valve repair

Device

Primary outcomes

  1. 30-Day Safety

    Time frame: 30-day

    Assess 30-day safety defined as device-related or procedure-related major adverse events (MAEs).

    MAE is a composite of death; myocardial infarction; emergent conversion to surgery; stroke; major cardiac structure complication; major vascular complication; and heart failure-related hospitalization.

Sponsors and collaborators

Lead sponsor

Ancora Heart, Inc.

Industry

Registry information

Official study title

Early Feasibility Study of the AccuCinch® Ventricular Restoration System

Important dates

Study start
2016
Primary completion
2020
Study completion
2024
First posted
Jun 20, 2016
Registry last updated
Jan 29, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.