Skip to main content
OpenTrials
Completed

NCT Number: NCT03699163

The Colorectal Breath Analysis (COBRA) Study

This study aims to determine whether a breath test could be used for early detection of colorectal cancer and colorectal polyps.

Patients who are attending for a planned colonoscopy or who are scheduled to undergo elective resection of histologically confirmed colorectal cancer (adenocarcinoma) will be approached to provide a breath sample.

Multi platform mass spectrometry analysis will be performed to establish volatile biomarkers that can discriminate between colorectal cancer, benign colorectal disease (e.g. polyps) and healthy controls.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–90 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Charing Cross Hospital, London, United Kingdom

Loading trial locations.

About this study

Colorectal cancer is the 2nd most common cause of cancer death in the UK where survival rates are among the lowest in Europe. If diagnosed early survival may exceed 90%.

The proposed breath test is a non-invasive investigation that can detect the presence of volatile organic compounds (VOCs) in breath and their relative abundance in disease states including colorectal cancer. This test has potential to be used in a primary care setting to identify patients at high risk of colorectal cancer, supporting earlier referral for definitive investigation. A negative test may provide reassurance to patients and prevent unnecessary tests in this group. The test could also have an application for colorectal cancer screening.

In this study the investigators will determine the diagnostic accuracy of an exhaled breath test for the detection of colorectal adenocarcinoma and colonic polyps. To determine the accuracy of the breath test a multicentre cross-sectional study will be conducted to analyse single breath samples from patients attending hospital for planned colonoscopy or elective resection of histologically confirmed colorectal cancer. The target for the study is 1463 patients.

Breath collection will be conducted using a previously validated method. Samples of breath (500ml) collected using a CE-marked handheld ReCIVA sampling device (Owlstone Medical Ltd., Cambridge, UK) during a period of tidal breathing (approximately 5minutes) will be absorbed onto thermal desorption tubes (Markes International, Llantrisant, UK). All patients will have received bowel preparation and will be fasted for a minimum of 6 hours prior to the breath sample. Breath samples collected within thermal desorption tubes will be transferred to a central laboratory for analysis by gas chromatography mass spectrometry (GC-MS) and proton transfer reaction time of flight mass spectrometry (PTR-ToF-MS). Raw data files will be extracted and analysed in accordance with established protocols. Quality assurance measures will be formally assessed at each stage of sample handling.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • ≥18 years and ≤90 years of age
  • Undergoing planned colonoscopy or elective resection of histologically confirmed colorectal adenocarcinoma
  • Fasted >6 hours
  • Able to provide informed written consent

Exclusion criteria

  • Any patient <18 years or >90 years of age.
  • Lacks capacity or is unable to provide informed written consent.

Treatment and study plan

Breath sample

Diagnostic Test

Patients will be asked to give a sample of their breath, using the ReCIVA breath testing device. This involves performing tidal breathing whilst wearing a face mask for approximately 5 minutes. Breath (500mls at a flow rate of 200mls/min) is passed over thermal desorption tubes which absorb compounds of interest.

Primary outcomes

  1. Determine the Diagnostic Accuracy of the Proposed Breath Test for Detection of Colorectal Cancer in All Patients

    Time frame: 30 minutes

    Diagnostic accuracy will be measured by calculating the sensitivity and specificity of the test for detection of colorectal cancer, as diagnosed on colonoscopy, using 14 specific VOCs plus BMI as prediction variables.

  2. Determine the Diagnostic Accuracy of Using VOCs Present in Breath for the Detection of Colorectal Cancer in Symptomatic Patients

    Time frame: 30 minutes

    Diagnostic accuracy will be measured by calculating the sensitivity and specificity of the test for detection of colorectal cancer, as diagnosed on colonoscopy, using 14 specific VOCs plus BMI as prediction variables.

Sponsors and collaborators

Lead sponsor

Imperial College London

Other

Collaborators

  • Imperial Health Charity
  • National Institute for Health Research, United Kingdom
  • Rosetrees Trust

Registry information

Official study title

Non-invasive Testing for the Diagnosis and Assessment of Colorectal Disease

Acronym: COBRA

Important dates

Study start
2017
Primary completion
2020
Study completion
2022
First posted
Oct 9, 2018
Registry last updated
Nov 21, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.