The aim of this study was to evaluate the validity and test-retest reliability of the 'TIB' Olfactory Test Device, a new olfactory test tool developed by Top International Biotech, Taipei, and to determine its normative values. The olfactory function of 180 subjects was evaluated using both the traditional Chinese version of the University of Pennsylvania of Smell Identification Test (UPSIT-TC) and TIB. The subjects consisted of 60 healthy volunteers (normosmic group), 60 hyposmic patients, and 60 anosmic patients. The healthy volunteers were retested with the UPSIT-TC and TIB at an inter-test interval of at least 7 days. The cut-off scores of TIB among the different groups were determined by receiver operating characteristic curve.
Looking for future studies?
Notify Me20 year–59 year
All sexes
Observational
Taichung, 407219, Taiwan
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
A new smell identification test, 'TIB' Olfactory Test Device (Top International Biotech, Taipei) has been developed in Taiwan. It consists of 16 tests with an odorant embedded in fragrant microcapsules positioned on a strip. The examinee scratches the strip to release the odorant. The released odorant is sniffed and the examinee identifies the odorant by choosing a name from a set of 4 odor descriptors. This process is then repeated with the next odorant on the strip.
The University of Pennsylvania Smell Identification Test (UPSIT), which was developed at the University of Pennsylvania, is one of the most reliable and the most widely used olfactory test.The test consists of four 10-odorant booklets. Each odorant is embedded in 10 to 50 µm urea-formaldehyde polymer microencapsules fixed in a proprietary binder and positioned on a brown strip which is located at the bottom of each page of the test booklet.4 When the examinee takes the test, each of the 40 odorants is released by scratching the strip with a pencil tip. The released odorant is sniffed and the examinee identifies the odorant by choosing a name from a set of 4 odor descriptors.
Time frame: 30 minutes to 1 hour
Criterion validity: Correlation between UPSIT-TC and TIB olfactory test
Time frame: 1 week
Test-retest reliability
Taichung Veterans General Hospital
Other
Validation of the Local Applicability of the 'TIB' Olfactory Test Device in the Era of COVID-19
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05445921
Anosmia, COVID-19
St Louis, Missouri, United States
View Trial DetailsNCT05184192
Anosmia, COVID-19
St Louis, Missouri, United States
View Trial DetailsNCT04789499
Ageusia, Anosmia
St Louis, Missouri, United States
View Trial DetailsNCT04853836
Anosmia, Behavior
Roma, Italy
View Trial Details