clinical evaluation of the effect of preheating BIS-GMA free resin composite at different temperatures on temperature change of the pulpal floor and restorations and compare it with BIS-GMA containing resin composite.
Hypothesis: Could the preheated composite affect the temperature of the pulpal floor
Looking for future studies?
Notify Me25 year–45 year
All sexes
Interventional
Not applicable
Minya, 61519, Egypt
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
evaluate the effect of preheating BIS-GMA free resin composite at different temperatures on temperature change of the pulpal floor and restorations and compare it with BIS-GMA containing resin composite.
Other names: warming of resin composite
Time frame: one year
evaluation the effect of preheating BIS GMA free resin composite at different temperature on temperature change of pulpal floor and restoration and compare it with BIS GMA containing resin composite
All readings were taken with the presence of a rubber dam and recorded in Celsius (°C).
Five temperature readings were measured for each tooth; (C0): pulpal floor temperature before beginning the restorative procedure. (C1): pulpal floor temperature during placement of preheated composite. (C2): top composite surface after packing and before curing. (C3): pulpal floor temperature after curing of the preheated composite. (C4): top composite surface after curing. The pulpal floor and the restoration temperature of each tooth was measured by a K-type temperature Probe attached to portable mini type thermometer device
Time frame: one year
Five temperature readings were measured for each tooth; (C0): pulpal floor temperature before beginning the restorative procedure. (C1): pulpal floor temperature during placement of preheated composite. (C2): top composite surface after packing and before curing. (C3): pulpal floor temperature after curing of the preheated composite. (C4): top composite surface after curing. The pulpal floor and the restoration temperature of each tooth was measured by a K-type temperature Probe attached to portable mini type thermometer device
Time frame: one year
Five temperature readings were measured for each tooth; (C0): pulpal floor temperature before beginning the restorative procedure. (C1): pulpal floor temperature during placement of preheated composite. (C2): top composite surface after packing and before curing. (C3): pulpal floor temperature after curing of the preheated composite. (C4): top composite surface after curing. The pulpal floor and the restoration temperature of each tooth was measured by a K-type temperature Probe attached to portable mini type thermometer device
Alshimaa Nasser Mahmoud
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.