TEE 3D RV Assessment for SAVR, Mini AVR, and TAVR

Three-dimensional echocardiography has become a gold standard to assess right ventricular (RV) function, and investigators plan to use 3D transesophageal echocardiography to assess RV function in 3 types of aortic valve replacement (AVR): full sternotomy surgical AVR (full-SAVR), mini-sternotomy surgical AVR (mini-SAVR), and transcatheter AVR (TAVR).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Thomas Jefferson University

Philadelphia, Pennsylvania, 19107, United States

About this study

Objective: Right ventricular (RV) function is known to be a critical factor to determine postoperative outcome in cardiac surgery, and echocardiography plays an important role in RV function assessment. In the previous studies, RV function was reported to be more reduced in surgical aortic valve replacement (SAVR) than transcatheter aortic valve replacement (TAVR), but its assessment was performed by 2-dimensional echocardiography. On the other hand, three-dimensional (3D) echocardiography has been the gold standard to assess RV systolic function (EF: ejection fraction), and its intraoperative use is getting more useful in cardiac surgery given recent technological advance in echocardiography machines. However, realty is that RV function assessment is based on subjective information or traditional RV function indices, mostly due to unfamiliarity of 3D technique.

In this study, the investigators plan to evaluate intraoperative RV function assessment by 3D transesophageal echocardiography (TEE). The investigators will compare 3D RV EF with other traditional RV function indices (RV fractional area change (FAC),, tricuspid annular plane systolic excursion (TAPSE) in full-SAVR, mini-SAVR, and TAVR.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adult patients over 18 years old
  • Patients who had SAVR, mini AVR, or TAVR

Exclusion criteria

  • Patients' refusal
  • Suboptimal echocardiography data for RVEF, RV size, RIMP, RVFAC, TAPSE, S', STE

Treatment and study plan

3D TEE RVEF

Diagnostic Test

With TEE package software, the investigators measure and calculate 3D TEE RVEF using mid esophageal 4 chamber view

Primary outcomes

  1. 3D RVEF (Baseline)

    Time frame: For SAVR and mini AVR, baseline is post general anesthesia induction, and postop is after chest closure, up to the end of procedure. For TAVR, baseline is post general anesthesia induction, and postop is after valve deployment, up to the end of procedure.

    RVEF assessed using 3D TEE at baseline

  2. %Change in 3D RVEF (From Baseline to Postop)

    Time frame: For SAVR and mini AVR, baseline is post general anesthesia induction, and postop is after chest closure, up to the end of procedure. For TAVR, baseline is post general anesthesia induction, and postop is after valve deployment, up to the end of procedure.

    (Postop 3D RVEF-baseline 3D RVEF)*100/baseline 3D RVEF

Secondary outcomes

  1. TAPSE (Baseline)

    Time frame: For SAVR and mini AVR, baseline is post general anesthesia induction, and postop is after chest closure, up to the end of procedure. For TAVR, baseline is post general anesthesia induction, and postop is after valve deployment, up to the end of procedure.

    TAPSE assessed using TEE at baseline

  2. RV FAC (Baseline)

    Time frame: For SAVR and mini AVR, baseline is post general anesthesia induction, and postop is after chest closure, up to the end of procedure. For TAVR, baseline is post general anesthesia induction, and postop is after valve deployment, up to the end of procedure.

    RV FAC assessed using TEE at baseline

  3. %Change in RV FAC (From Baseline to Postop)

    Time frame: For SAVR and mini AVR, baseline is post general anesthesia induction, and postop is after chest closure, up to the end of procedure. For TAVR, baseline is post general anesthesia induction, and postop is after valve deployment, up to the end of procedure.

    (Postop RV FAC-baseline 3D RV FAC)*100/baseline RV FAC

  4. %Change in TAPSE (From Baseline to Postop)

    Time frame: For SAVR and mini AVR, baseline is post general anesthesia induction, and postop is after chest closure, up to the end of procedure. For TAVR, baseline is post general anesthesia induction, and postop is after valve deployment, up to the end of procedure.

    (Postop TAPSE-baseline TAPSE)*100/baseline TAPSE

Sponsors and collaborators

Lead sponsor

Thomas Jefferson University

Other

Registry information

Official study title

Utility of Three-dimensional Transesophageal Echocardiography in Right Ventricular Function Assessment in Surgical Aortic Valve Replacement, Mini-sternotomy Aortic Valve Replacement, and Transcatheter Aortic Valve Replacement

Important dates

Study start
2023
Primary completion
2025
Study completion
2025
First posted
Apr 7, 2023
Registry last updated
May 13, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.