TC-A PS Total Knee Replacement System
DeviceSubject will be implanted with the TC-A PS Total Knee Replacement System
Other names: TC-A PS
NCT Number: NCT02139345
This is a prospective, randomized, multicenter clinical study to compare the safety and efficacy of TC-A PS total knee system with TC-PLUS Solution PS total knee system in Chinese subjects.
Looking for future studies?
Notify Me50 year–75 year
All sexes
Interventional
Not applicable
Nanjing First Hospital, Nanjing, Jiangsu, China
Osteoarthritis (OA), also known as degenerative joint disease or hyperostosis, is the most common cause of knee arthritis. Pain, dyskinesia and disability induced by osteoarthritis impact severely on the subject's health and quality of life. Knee osteoarthritis is very common in the elderly population. As life expectancy has increased, the incidence of osteoarthritis rose significantly during the 20th century. For people over 60 years of age, approximately 50% show signs of osteoarthritis on x-rays, among which 35% -50% show clinical signs. For people over the age of 75, 80% had osteoarthritis symptoms.
There has been an increase in imported knee prostheses during the past decade, so that surgeons now have more choices of implants. However, the high cost of imported prostheses has become a barrier to the development of TKA in China and caused many OA subjects requiring immediate TKA to have to delay or miss their surgery. The development and promotion of high-quality domestic joint implants and surgical instruments is the key to the development of TKA technique in China.
The primary objective of this study is to demonstrate non-inferiority of subjects implanted with the TC-A PS total knee system compared to a randomized concurrent control group of subjects implanted with the TC-PLUS Solution PS total knee system in terms of Knee Society Clinical Score (KSCS) at 1 year.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Subject will be implanted with the TC-A PS Total Knee Replacement System
Other names: TC-A PS
Subject will be implanted with the TC-PLUS Solution PS Total Knee Replacement System
Other names: TC-PLUS Solution PS
Time frame: 1 year post-operative
The Knee Society Clinical Score (KSCS) - points are given for pain, motion, and stability and points are deducted for flexion contracture, extension lag, and misalignment. For the results, a score of 80-100 = excellent, 70-79 = good; 60-69 = fair; and < 60 = poor.
Time frame: 1 year post-operative
The Knee Functional Score (KSFS) - points are assigned for walking distances and climbing stairs and points are deducted for use of walking aids. For the result, a score of 80-100 = excellent, 70-79 = good; 60-69 = fair; and < 60 = poor.
Time frame: Up to 1 year post-operative
Revision for any reason will be assessed and documented up to 1 year post-operative.
Time frame: Up to 1 year post-operative
Radiographic measurements will be taken of linear radiolucencies and the radiographs will be evaluated for any abnormalities.
Time frame: 1 year post-operative
The Western Ontario and McMaster Universities Arthritis Index (WOMAC) is a widely used, proprietary set of standardized questionnaires used by health professionals to evaluate the condition of subjects with osteoarthritis of the knee and hip, including pain, stiffness, and physical functioning of the joints.
The WOMAC measures five items for pain (score range 0-20), two for stiffness (score range 0-8), and 17 for functional limitation (score range 0-68). Physical functioning questions cover everyday activities such as stair use, standing up from a sitting or lying position, standing, bending, walking, getting in and out of a car, shopping, putting on or taking off socks, lying in bed, getting in or out of a bath, sitting, and heavy and light household duties.
Time frame: 1 year post-operative
The SF-12 Health Survey was first developed in 1995 as a shorter version of the SF-36 Health Survey used for measuring the overall health condition of the general population. The usefulness of SF-12 is improved by its simplicity and less time needed for completion, and it has a good reliability on the evaluation of quality of life. The SF-12v2 Health Survey is a 12-item generic Health-Related Quality of Life measure consisted of eight subscales: Physical functioning (PF), Role physical (RP), Bodily pain (BP), General health (GH), Vitality (VT), Social functioning (SF), Role emotional (RE) and Mental health (MH); and two composite summary scores: Physical Component Summary (PCS) and Mental Component Summary (MCS) scores. All subscales and summary scores were ranged from 0-100. The higher the SF-12 score, the better the HRQOL outcome.
Time frame: Up to 1 year post-operative
Safety will be evaluated by collecting the frequency and nature of all postoperative adverse events
Smith & Nephew Medical (Shanghai) Ltd
Industry
A Prospective, Randomized, Multicenter Clinical Study to Compare the Safety and Efficacy of TC-A PS Total Knee System With TC-PLUS Solution PS Total Knee System in Chinese Subjects
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06012656
Arthritis, Arthritis, Rheumatoid
Soyaux, France
View Trial DetailsNCT02679352
Arthritis, Arthritis, Rheumatoid
Herne, Germany
View Trial DetailsNCT04425603
Avascular Necrosis, Bone Diseases
Ashford, United Kingdom
View Trial DetailsNCT05926622
Arthritis, Avascular Necrosis
Annecy, France
View Trial Details