Acibadem Altunizade Hospital
Istanbul, 31190, Turkey (Türkiye)
NCT Number: NCT05708638
Hemodynamic changes during induction of anesthesia may have adverse outcomes and should therefore be avoided. The decrease in blood pressure during induction of anesthesia with propofol is due to a decrease in systemic vascular resistance or cardiac output and may be increased by the concomitant use of other drugs such as remifentanil. Target controlled infusion (TCI) system aims to reach the theoretically targeted blood or brain concentration of anesthetic agents based on the patient's age, weight, and height, with computer-assisted algorithms. In manual anesthesia induction, anesthetic agents are administered at a fixed dose and rate adjusted according to the patient's weight, which may cause hypotension in patients with low cardiovascular performance. As target-controlled infusion (TCI) obviates the need to calculate the infusion rate manually, the use of TCI may provide a better hemodynamic profile during anesthesia induction This study was designed to test the hypothesis that propofol by TCI anesthesia induction is associated with a lower hypotension rate when compared with manual anesthesia induction
Looking for future studies?
Notify Me18 year–90 year
All sexes
Interventional
Not applicable
Istanbul, 31190, Turkey (Türkiye)
Maintaining normotension is one of the top priorities for anesthesiologists due to its negative effects. Although there are a lot of studies and knowledge on the topic approximately 20-30% of patients develop post-induction hypotension. Mostly it occurs due to the adverse effects of anesthetics such as a decrease in systemic vascular resistance or cardiac output and the interplay between them. The risk can be minimized in two steps: first by identifying high-risk patients, and second with tight control of hemodynamic parameters. As a second step, tight hemodynamic control during induction may be done using target-controlled infusion (TCI) systems, which systems help to adjust the dosage to the needs of each patient by measuring hypnotic effects through the bispectral index (BIS).
TCI models for propofol have been previously compared with manual infusions, however, it is not clear whether it still contributes to or triggers hemodynamic deterioration. Therefore in this study, the investigators' aim is to determine the effect of two different anesthesia techniques on the development of postinduction hypotension through hemodynamic parameters monitored by the pressure recording analytical method (PRAM). The secondary aim is to identify risk factors that can predict postinduction hypotension
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
In manual anesthesia induction, anesthetic agents are administered at a fixed dose and rate adjusted according to the patient's weight
Other names: Manuel induction
Target controlled infusion (TCI) system aims to reach the theoretically targeted blood or brain concentration of anesthetic agents based on the patient's age, weight, and height, with computer-assisted algorithms.
Other names: TCI induction
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Systolic arterial pressure (SAP- mm/Hg) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). SAP is a parameter used to assess the pressure of the arterial system during cardiac systole
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Diastolic arterial pressure (DAP, mm/Hg) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). DAP is a parameter used to assess the pressure of the arterial system during cardiac diastole.
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Mean arterial pressure (MAP, mm/Hg) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). MAP is a parameter used to assess organ perfusion
Time frame: he duration of the study was defined from one minute before induction to 10 minutes after induction
Ea ((mmHg m-2ml-1)is an indicator of cardiac afterload and arterial tone and can be calculated by the ratio of the end-systolic pressure (ESP) and stroke volume (SV) obtained from arterial wave analysis. Ea was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy) before the anesthesia induction
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction]
Stroke volume variation (SVV,%), was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). SVV is a parameter used to asses cardiac preload and fluid responsiveness
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Pulse pressure variation (PPV,%) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). PPV is a parameter used to asses cardiac preload and fluid responsiveness.
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Cardiac power output (CPO, Watt) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). CPO is a parameter used to asses cardiac reserve
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Cardiac index (CI, L/min/m2), was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). CI is a parameter used to asses cardiac stroke volume
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Dp/Dt(mmHg/msn), was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). Dp/Dt is a parameter used to asses cardiac contractility.
Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction
Heart rate (HR/bpm) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). HR is a parameter used to assess the cardiac rate.
Acibadem University
Other
Does Anesthesia Induction With Target-controlled Infusion Reduce Post-induction Hypotension?
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04137991
Cardiac Surgery, General Anesthesia
Brussels, Belgium
View Trial DetailsNCT04399278
General Anesthesia, Hemodynamic Instability
Clermont-Ferrand, France
View Trial DetailsNCT07040631
Breast Cancer, Breast Diseases
Yangsan, Gyeongsangnam-do, South Korea
View Trial DetailsNCT07199049
Eye Movements, General Anesthesia
Başakşehir, Istanbul, Turkey (Türkiye)
View Trial Details