NCT Number: NCT02266407
To assess the surgical and economic effectiveness of the Aquamantys System in managing intra- and post-operative blood loss, and reducing transfusion needs in patients undergoing both aseptic and septic revision total knee arthroplasty.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Markgröningen, 71706, Germany
The use of the saline-coupled bipolar sealing technology (Aquamantys® System, Medtronic Advanced Energy, LLC, Portsmouth, NH, USA) represents a modern approach to reducing perioperative blood loss in patients undergoing total joint arthroplasty. Unlike standard electrocautery, which use monopolar radiofrequency energy, this technology uses bipolar radiofrequency energy combined with a continuous-flow saline at the electrode tip to prevent tissue temperatures from exceeding 100 °C thus minimizing tissue charring. This eliminates the smoke and eschar formation seen with standard electrocautery. The temperature achieved is sufficient to induce a process called Transcollation(TM) which shrinks the collagen fibers in the walls of blood vessels, effectively sealing the blood vessels up to 1mm in diameter, resulting in the reduction of bleeding from soft tissue.
Suction is used to remove the saline from the surgical field with the treated tissue turning a light tan color. With normal use, the depth of penetration of this effect is typically less than 2mm. The technology is cleared by the US FDA (510(k)) and EU (CE Mark) for use on soft tissue & bone and will be used according to its intended packaging indications for use. The current assessment proposes a technique in which a disposable Aquamantys® hand piece is used to treat targeted areas which are bleeding or expected to bleed during surgery.
This postmarket study will assess the surgical and economic effectiveness of Aquamantys® System in managing intra-operative blood loss and transfusion rates in patients undergoing septic and aseptic revision TKA.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The use of the saline-coupled bipolar sealing technology (Aquamantys® System, Medtronic Advanced Energy, LLC, Portsmouth, NH, USA) uses bipolar radiofrequency energy combined with a continuous-flow saline at the electrode tip to prevent tissue temperatures from exceeding 100 °C thus minimizing tissue charring. The temperature achieved is sufficient to induce a process called Transcollation(TM) which shrinks the collagen fibers in the walls of blood vessels, effectively sealing the blood vessels up to 1mm in diameter, resulting in the reduction of bleeding from soft tissue.
Time frame: 14 days
To reduce blood loss and post-operative transfusion rates in patients undergoing total joint arthroplasty. This will be achieved using the Aquamantys system. The Aquamantys system provides transcollation which shrinks the collagen fibers in the walls of blood vessels, effectively sealing the blood vessels up to 1mm in diameter, resulting in the reduction of bleeding from soft tissue.
Time frame: 14 days
The data to be collected will include, but is not limited to: copies of the subjects' hospital bills, corresponding Explanation of Benefits (EOB), physician's bill, or itemized hospital bills. The economic form(s) are collected and copies are provided to the sponsor.
Time frame: 14 days
As data is collected from subject record an analysis of this data will provide changes in hemoglobin levels
Medtronic Surgical Technologies
Industry
The Surgical and Economic Effect of the Aquamantys System in Blood Management During and Following Aseptic and Septic Revision TKA
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03192124
Infection of Total Knee Joint Prosthesis, Infections
Los Angeles, California, United States
View Trial DetailsNCT04993027
Infection of Total Hip Joint Prosthesis, Infection of Total Knee Joint Prosthesis
View Trial DetailsNCT07737366
Anxiety, Anxiety Disorders
Sakarya, Turkey (Türkiye)
View Trial DetailsNCT06690554
Behavior, Disorders of Environmental Origin
Konya, Turkey (Türkiye)
View Trial Details