faculty of dentistry, Mansoura univeristy
Al Mansurah, Egypt
NCT Number: NCT06179615
Purpose: This study aimed to assess the 3-dimentional wear )3D) (volumetric loss) and 2-dimentional wear (2D) (vertical loss) and surface hardness of ready-made (prefabricated) and CAD/CAM milled artificial denture teeth.
material and methods: In a cross-over study design, ten completely edentulous patients were randomly chosen for this study and given two complete dentures. The first complete denture was constructed with pre-fabricated teeth. The second complete denture was constructed with CAD\\CAM milled teeth. The complete denture teeth were 3D scanned at the time of insertion (T0), after three months (T3), and after six months (T6) of denture insertion. Utilizing 3D surface superimposition techniques, the vertical (2D wear), and Volumatic (3D wear) material loss were measured. The hardness of the teeth were evaluated at the time of denture insertion (T0) then after 6 months (T6) of denture insertion by Vickers hardness test. Statistical analysis was done using SPSS software. Paired groups were compared by paired t test. Significant difference was considered if P ≤ 0.05.
Looking for future studies?
Notify Me55 year–65 year
All sexes
Interventional
Not applicable
Al Mansurah, Egypt
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
surface hardness test of denture teeth at insertion then after 6 months of use
2D, Vertical wear, 3D Volumetric wear were measured for denture teeth
Time frame: 6 months after denture use
2D, 3D wear of denture teeth were measured using denture scanning and superimposition of the sanning at insertion to that after 3, 6 months using Exocad soft ware
Time frame: 6 months after denture use
the measurement of surface hardness was done using Vickers's test. this measurements was done at insertion then after 6 months
Mansoura University
Other
Surface Hardness and Wear Resistance of Prefabricated and CAD/CAM Milled Artificial Teeth: A Cross-over Clinical Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.