SalaUno Salud, S.A.P.I. de C.V.
Mexico City, Mexico
NCT Number: NCT04702802
Pilot, controlled, parallel group, open, randomized clinical trial to evaluate the safety of the viscoelastic substance PRO-149 (sodium hyaluronate 3%) after trans-surgical administration as a device in performing phacoemulsification and intraocular lens implantation in 36 patients with age-related cataract, compared to Healon® EndoCoat (sodium hyaluronate 3%).
Looking for future studies?
Notify Me49 year and older
All sexes
Interventional
Not applicable
Mexico City, Mexico
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
During intraocular surgery phacoemulsification and intraocular lens implantation, patients with age-related cataract will be exposed to injection of viscoelastic device in the anterior chamber, allowing the procedure to take place.
Other names: PRO-149
Time frame: Days: -15 (±2) (eligibility visit), and 29 (±2) (final visit)
By means of specular microscopy, endothelial cell count will take place. Density expressed in cells/mm2 will be recorded. Normal density varies according to age, but an average of 1500 - 3500 cells/mm2 (age 40 to 90) has been described.
Time frame: Days: -15 (±2) (eligibility visit [EV]), 1 (first safety evaluation visit [V1]), 8 (±2) (second safety evaluation visit [V2]), and 29 (±2) (final visit [FV])
Measured through Goldman tonometer in milligrams of mercury (mmHg). After instillation of topical anesthetic (tetracaine 0.5%) and fluorescein stain, IOP is evaluated twice to obtain an average to be recorded. Normal values are considered between 10 and 21 mmHg.
Time frame: From Day -15 (±2) (eligibility visit) through Day 29 (±2) (final visit)
Presence/absence adverse events, defined as the appearance of any unfavorable reaction in a patient participating in a clinical investigation in which any pharmaceutical product is being administered, regardless of the causal attribution.
Time frame: Days: -15 (±2) (eligibility visit [EV]), and 29 (±2) (final visit [FV])
By means of specular microscopy, corneal thickness will be evaluated, reported in μm.
Time frame: Days: -15 (±2) (eligibility visit [EV]), 1 (first safety evaluation visit [V1]), 8 (±2) (second safety evaluation visit [V2]), and 29 (±2) (final visit [FV])
During evaluation with a slit lamp, setting the beam of light to 0.2 mm x 0.2 mm dimensions, it will be obliquely aimed to the anterior chamber. The Standardization of Uveitis Nomenclature (SUN) system was used for grading this variable, according to number of observed cells: grade 0 (none), grade ½+ (1-5 cells), grade 1+ (6-15 cells), grade 2+ (16-25 cells), grade 3+ (26-60 cells), grade 4+ (>60 cells). A higher score represents a worse outcome.
Time frame: Days: -15 (±2) (eligibility visit [EV]), 1 (first safety evaluation visit [V1]), 8 (±2) (second safety evaluation visit [V2]), and 29 (±2) (final visit [FV])
During evaluation with a slit lamp, setting the beam of light to 0.2 mm x 0.2 mm dimensions, it will be obliquely aimed to the anterior chamber. The Standardization of Uveitis Nomenclature (SUN) system was used for grading this variable: grade 0 (No flare), grade 1+ (Mild), grade 2+ (Moderate; iris and lens clearly visible), grade 3+ (Marked; slightly blurry iris and lens), grade 4+ (>60 cells; fibrin). A higher score represents a worse outcome.
Time frame: Days: -15 (±2) (eligibility visit [EV]), 1 (first safety evaluation visit [V1]), 8 (±2) (second safety evaluation visit [V2]), and 29 (±2) (final visit [FV])
With the patient's best possible refractive correction, visual acuity will be evaluated through the Snellen chart. Its notation (fraction or decimal) is described as the distance from the chart at which the test is performed, divided by the distance at which a letter equals vertically 5 minutes of arc.
Time frame: Days: 0 (surgery)
During the phacoemulsification and intraocular lens implantation, the surgeon will evaluate the performance of the viscoelastic substance used during the procedure trough a questionnaire that will inquire on the following: Capability to maintain a formed anterior chamber during continuous circular capsulorhexis and intraocular lens implantation, retention during phacoemulsification, user-friendliness, ergonomics, ease of use during capsulorhexis, transparency during surgery and ease of use during extraction. Scale: 0 (very bad), 1 (bad), 2 (acceptable), 3 (good), 4 (very good).
Laboratorios Sophia S.A de C.V.
Industry
Clinical Study to Evaluate the Safety of the Viscoelastic Substance PRO-149 When Used as a Device During Phacoemulsification and Intraocular Lens Implantation in Patients With Age-related Cataract, Compared to Healon® EndoCoat.
Acronym: PRO-149
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07548294
Age-related Cataract, Behavior
Sakarya, Adapazarı, Turkey (Türkiye)
View Trial DetailsNCT07517094
Adrenergic Receptor Antagonist Adverse Reaction, Age-related Cataract
Olomouc, Czechia
View Trial DetailsNCT05802550
Age-related Cataract, Cataract
Tours, France
View Trial DetailsNCT05396547
Age-related Cataract
Liepāja, Latvia
View Trial Details