Study of the Relay Pro® Thoracic Stent-Graft in Subjects With Traumatic Injury of the Descending Thoracic Aorta

The purpose of this study is to investigate the safety and effectiveness of the RelayPro Thoracic Stent-Grafts in subjects with traumatic injury of the descending thoracic aorta (DTA)

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University of California, Irvine, Irvine, California, United States

Loading trial locations.

About this study

This is a prospective, multicenter, non-blinded, non-randomized study of the RelayPro Thoracic Stent-Graft in subjects with traumatic injury of the DTA in subjects who are candidates for endovascular repair.The primary objective of the study is all-cause mortality at 30 days post procedure.

The secondary objectives of the trial will include descriptive analyses of procedural and post-procedural observations through 5 years of follow-up.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age greater than 18 years
  • Subject must have a traumatic injury of the descending thoracic aorta that occurred no more than 30 days prior to the planned stent implant procedure
  • Proximal and distal landing zones with diameter between 19 mm and 42 mm.
  • Subject must have a proximal attachment zone distal to the left common carotid and a distal attachment zone proximal to the origin of the celiac artery.
  • The length of the attachment zones will depend on the intended stent graft diameter.
  • The proximal attachment zone should be: i. 15 mm for 22 - 28 mm grafts with bare stent (20 mm for RelayPro grafts with non-bare stent). ii. 20 mm for 30 - 46 mm grafts with bare stent (25 mm for RelayPro grafts with non-bare stent).
  • The distal attachment zone should be 20 mm for all Relay Pro grafts.
  • Coverage of the left subclavian artery is permitted. Revascularization of the left subclavian artery may be considered in all cases by the treating physician and, especially, in anatomies where revascularization is determined to be clinically necessary
  • Proximal and distal attachment zones containing a straight segment (non-tapered, non-reverse tapered, defined by <10% diameter change) with lengths equal to or greater than the required attachment length for the intended device.
  • Adequate iliac or femoral artery access for introduction of the RelayPro delivery system. Alternative methods to gain proper access may be utilized (e.g., iliac conduit).
  • Subject willing to comply with the follow-up evaluation schedule.
  • Subject (or Legally Authorized Representative, LAR) agrees to sign an Informed Consent Form prior to treatment

Exclusion criteria

  • Significant stenosis, calcification, thrombus, or tortuosity of intended fixation sites that would compromise fixation or seal of the device.
  • Planned coverage of left carotid or celiac arteries; or anatomic variants that may compromise circulation to the carotid, vertebral, or innominate arteries after device placement, and are not amenable to subclavian revascularization
  • Prior endovascular or surgical repair in the DTA. The device may not be placed within any prior endovascular or surgical graft.
  • Concomitant aneurysm/disease of the ascending aorta, aortic arch, or abdominal, aorta requiring repair.
  • Prior abdominal aortic aneurysm repair (endovascular or surgical) that was performed less than 6 months prior to the planned stent implant procedure.
  • Untreatable allergy or sensitivity to contrast media or device components.
  • Known or suspected connective tissue disorder.
  • Blood coagulation disorder or bleeding diathesis for which the treatment cannot be suspended for one week pre- and/or post-repair.
  • Coronary artery disease with unstable angina.
  • Severe congestive heart failure (New York Heart Association functional class IV).
  • Stroke and/or Myocardial Infarction within 3 months of the planned treatment date.
  • Pulmonary disease requiring the routine (daily or nightly) need for oxygen therapy outside the hospital setting.
  • Acute renal failure or chronic renal insufficiency, and not receiving dialysis.
  • Hemodynamically unstable.
  • Active systemic infection and/or mycotic aneurysms.
  • Morbid obesity or other condition that may compromise or prevent the necessary imaging requirements.
  • Injury Severity Score of 75.
  • Less than two-year life expectancy.
  • Current or planned participation in an investigational drug or device study that has not completed primary endpoint evaluation.
  • Currently pregnant or planning to become pregnant during the course of the study.
  • Medical, social, or psychological issues that Investigator believes may interfere with treatment or follow-up.

Treatment and study plan

Relay Pro Thoracic Stent-Graft System

Device

RelayPro Thoracic Stent-Grafts are designed for the management of patients with aneurysms and penetrating ulcers within the descending thoracic aorta (DTA). The device is designed specifically for use in the thoracic aorta.

Primary outcomes

  1. Mortality post-procedure

    Time frame: 30 days

    All-cause mortality at 30 days post-procedure

Secondary outcomes

  1. Successful device delivery and deployment

    Time frame: During Implantation

    Successful delivery and deployment of the device, including withdrawal of the delivery system, will be assessed with angiography during the index procedure at the Treatment Visit.

  2. Loss of stent-graft patency

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Loss of stent-graft patency through 5 years

  3. Aortic rupture

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Aortic rupture will be assessed at each follow-up visit with CT scans, or MRIs for subjects unable to tolerate contrast media

  4. Stent fractures in the attachment zone

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Stent fractures in the attachment zone will be assessed at each follow-up visit with CT scans, or MRIs for subjects unable to tolerate contrast media

  5. Endoleaks

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Persistence of blood flow outside the lumen of the stent-graft but within the native aorta or adjacent vascular segment being treated by the stent-graft

  6. Compression of stent-graft

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Extra-luminal compression of the stent-graft will be assessed at each follow-up visit with xrays, CT scans, or MRIs for subjects unable to tolerate contrast media

  7. Erosion and/or extrusion

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Erosion and extrusion will be assessed at each follow-up visit with CT scans, or MRIs for subjects unable to tolerate contrast media

  8. Aortic expansion

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Aortic expansion (> 5mm) compared to the first post-procedural CT

  9. Endograft infection

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Infection of stent-graft

  10. Incidence of open or endovascular secondary interventions

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Incidence of open or endovascular secondary interventions to treat malperfusion, rupture, aneurysm formation, or aortic expansion

  11. Migration

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    Stent migration (> 10 mm) compared to the first post-procedural CT; formation, or aortic expansion

  12. Major adverse events

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    death, stroke, paralysis formation, or aortic expansion

  13. Aortic-related death

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    formation, or aortic expansion

  14. Vascular access complications

    Time frame: During the initial implant attempt

    The Time Frame for reporting is during the Treatment Visit. Data should be captured upon conclusion of the Treatment Visit. Outcome measures include successful delivery and deployment of the device, as well as withdrawal of the delivery system

  15. All-cause mortality

    Time frame: 1 month, 6 months, 12 months, and annually through 5 years

    All causes where subject death is the result of a serious and device- or procedure related adverse effect. Unrelated and accidental deaths, for example a subject death due to injuries sustained from a gunshot wound, would not be included in the evaluation.

Sponsors and collaborators

Lead sponsor

Bolton Medical

Industry

Registry information

Official study title

A Prospective, Multicenter, Non-Blinded, Non-Randomized Study of the RelayPro Thoracic Stent-Graft in Subjects With Traumatic Injury of the Descending Thoracic Aorta

Important dates

Study start
2017
Primary completion
2020
Study completion
2025
First posted
Mar 24, 2017
Registry last updated
May 31, 2025