ELLIPTA
DeviceDry powder inhaler (placebo) with two blister strips. One placebo strip containing lactose monohydrate and a second placebo strip containing lactose monohydrate blended with magnesium stearate.
NCT Number: NCT02184624
This is a randomised, open-label, placebo, crossover, multicentre study with a single visit. The study will comprise five sub-studies. Subjects will receive inactive treatment (placebo) via the ELLIPTA® inhaler and one of the other inhaler devices depending on the sub-study they are randomised to. Only subjects who are naïve to the ELLIPTA inhaler and to one of the other inhaler devices that will be used in this study will be included. Furthermore, subjects who are naïve to the BREEZEHALER® and HANDIHALER® inhalers must be naïve to all other inhaler devices that requires a capsule. The study will be conducted in the UK and the Netherlands, and comprises one visit only. A sufficient number of subjects (at least 600) with COPD will be screened and 570 will be randomised to one of five sub-studies. Eligible subjects will be allocated to one of the sub-studies depending on their experience of using the other inhaler (i.e., depending on which other inhaler they are naïve to).
This study is designed to assess the proportion of COPD subjects making critical and overall (i.e., critical and non-critical errors) errors in using ELLIPTA inhaler and other commercially available inhaler devices such as the TURBUHALER®, HANDIHALER, BREEZHALER, MDI and DISKUS®/ACCUHALER® inhalers. This study will also assess the 'ease of use' and preference between the ELLIPTA inhaler and the other commercially available inhaler devices.
ELLIPTA, DISKUS, and ACCUHALER are registered trademarks of the GSK group of companies. TURBUHALER is a registered trademark of AstraZeneca. HANDIHALER is a registered trademark of Boehringer Ingelheim Pharma GmbH & Co. KG. BREEZHALER is a registered trademark of Novartis AG.
Looking for future studies?
Notify Me40 year and older
All sexes
Interventional
Phase 4
GSK Investigational Site, Almere Stad, Netherlands
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Dry powder inhaler (placebo) with two blister strips. One placebo strip containing lactose monohydrate and a second placebo strip containing lactose monohydrate blended with magnesium stearate.
Placebo inhaler with one blister strip containing lactose monohydrate.
Placebo inhaler containing propellant (1,1,1, 2-Tetrafluoroethane).
Placebo inhaler containing lactose monohydrate.
Placebo inhaler containing lactose monohydrate in a capsule.
Placebo inhaler containing lactose monohydrate in a capsule.
Time frame: Day 1
A critical error was defined as an error that was most likely to result in no or only minimal medication being inhaled. The errors considered as critical errors while handling the inhaler devices were failed to open cover, lever was not pushed back, shook the device after dose preparation, exhaled directly into mouthpiece, no seal by the lips round the mouthpiece during the inhalation. As per the crossover study design participants received placebo via the ELLIPTA inhaler first and then non-ELLIPTA inhaler or non-ELLIPTA inhaler first and then ELLIPTA on Day 1. The percentage of participants who made at least one critical error was reported for each inhaler regardless sequence.
Time frame: Day 1
An overall error includes a critical and non-critical error. Any error made by the participants while demonstrating the use of the inhaler after reading the patient instruction leaflet was recorded by health care professional (HCP). The percentage of participants who made at least one overall error was reported. As per the crossover study design participants received placebo via the ELLIPTA inhaler first and then non-ELLIPTA inhaler or non-ELLIPTA inhaler first and then ELLIPTA on Day 1.
Time frame: Day 1
A critical error was defined as an error that was most likely to result in no or only minimal medication being inhaled. The errors considered as critical errors while handling the inhaler devices were failed to open cover, lever was not pushed back, shook the device after dose preparation, exhaled directly into mouthpiece, no seal by the lips round the mouthpiece during the inhalation. As per the crossover study design participants received placebo via the ELLIPTA inhaler first and then non-ELLIPTA inhaler or non-ELLIPTA inhaler first and then ELLIPTA on Day 1. If the participant made any error while demonstrating the use of the inhaler after reading the patient instruction leaflet, the HCP demonstrated the correct usage of the inhaler to the participant. The participants were then asked to demonstrate inhaler use again. If any further critical error were made by the participant, the error were recorded by HCP.
Time frame: Day 1
An overall error includes a critical and non-critical error. If the participant made any error while demonstrating the use of the inhaler after reading the patient instruction leaflet, the HCP demonstrated the correct usage of the inhaler to the participant. The participants were then asked to demonstrate inhaler use again. If any further error was made by the participant was recorded by HCP.
Time frame: Day 1
If the participant made any error while demonstrating the use of the first inhaler after reading the patient instruction leaflet, the HCP demonstrated the correct usage of the inhaler to the participant. The participant was then asked to demonstrate inhaler use again. Any errors made by the participant were recorded by the HCP. The same procedure was repeated if the participant continues to make errors in the use of the inhaler. In total, the HCP demonstrated the use of the inhaler up to three times. Same procedure was followed for second inhaler. The number of participants who demonstrated the adequate inhalation technique after third time instructions from HCP was reported.
Time frame: Day 1
After completing the demonstration procedures of the inhalers, the HCP asked the participant a number of questions from preference questionnaire. Preference questionnaire consisted of eight questions related to both inhalers used during the study. Each question had one response to choose from 3 preference options (Other inhaler device, ELLIPTA inhaler device and No preference). The number of participants who overall preferred the ELLIPTA device compared to non-ELLIPTA inhalers (First question in the preference questionnaire) were reported.
Time frame: Day 1
After completing the demonstration procedures of the inhalers, the HCP asked the participant a number of questions from ease of use questionnaire. Ease of use questionnaire consisted of six questions each for ELLIPTA inhaler and the other inhaler under study. Each question had one response to choose from 5 options of ease of use (Very easy, easy, neutral, difficult and very difficult). Based upon the response given by the participants the number of participants who rated ease of use higher for ELLIPTA, higher for non- ELLIPTA, or rated the same were reported
GlaxoSmithKline
Industry
An Open-label Study of Inhaler Device Attributes Investigating Critical and Overall Errors, Ease of Use, and Preference Between a Number of Inhaler Devices (ELLIPTA, TURBUHALER, HANDIHALER, BREEZHALER, MDI, and DISKUS/ACCUHALER) in Adult Subjects With Chronic Obstructive Pulmonary Disease (COPD)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07252908
Chronic Disease, Disease Attributes
Chongqing, Chognqing, China
View Trial DetailsNCT07649577
Asthma, Bronchial Diseases
Amman, Jordan
View Trial DetailsNCT06979518
Chronic Disease, Disease Attributes
Cypress, California, United States
View Trial DetailsNCT06367686
Apnea, Chronic Disease
Tønsberg, Norway
View Trial Details