Steno Diabetes Center Aarhus
Aarhus, Denmark
NCT Number: NCT03782441
This explorative clinical study has been launched to collect spectral Raman data paired with validated glucose reference values in diabetic patients.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Aarhus, Denmark
The Investigational Medical Device (IMD) for this investigation is the Prototype 0.5 (P0.5) developed and manufactured by RSP Systems (RSP). The device is intended for non-invasive interstitial intermittent glucose monitoring in persons (age 18 and older) with diabetes. The technology relies on the well-established capacities of Raman spectroscopy for directly detecting glucose subcutaneously. The Raman spectroscopy physical principle relies on the fact that when laser light of a given wavelength interferes with a molecule, a small fraction of the incident light will interact with the vibrational states of the molecule, causing the photons to lose a portion of their energy which will change the wavelength of the light. The scattered light will be collected by the optical probe head and analyzed with advanced algorithms to correlate the signal to glucose concentrations. Data collected from the IMD will be paired with validated glucose reference values collected by the finger sticking method.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Investigational Medical Device collecting spectral Raman data from tissue
Time frame: 4 months
Accuracy of measurements performed on the IMD will be evaluated by data from subjects. Data will be analyzed by Mean Absolute Relative Difference (MARD) and Inter Subject Unified Performance (ISUP)
Time frame: 4 months
Safety of the IMD will be evaluated in a descriptive manner by the paucity of adverse events reported during the clinical study
Time frame: 4 months
Description of device deficiencies will be listed. Deficiencies will be reported during the clinical study.
Time frame: 4 months
The use of the device by the subjects will be evaluated by means of questionnaires
RSP Systems A/S
Industry
A Pilot Study of a Novel Non-invasive Glucose Monitoring Device
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00038727
Body Weight, CVD
Rockville, Maryland, United States
View Trial DetailsNCT06029517
Arterial Occlusive Diseases, Arteriosclerosis
Buffalo, New York, United States
View Trial DetailsNCT01934660
Cardiovascular Disease, Cardiovascular Diseases
Bethesda, Maryland, United States
View Trial DetailsNCT07728162
Diabetes Mellitus, Disease Attributes
Bolu, Turkey (Türkiye)
View Trial Details