0.454% w/w stannous fluoride (1100ppm fluoride)
OtherDentifrice containing 0.454% w/w stannous fluoride (1100ppm fluoride)
NCT Number: NCT02705716
This study will investigate the efficacy of an experimental dentifrice containing 0.454% weight/weight (w/w) stannous fluoride in relieving dentine hypersensitivity (DH) after twice daily brushing, over a 2 week treatment period compared with a standard fluoride dentifrice.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
GSK Investigational Site, Ellesmere Port, Cheshire, United Kingdom
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Dentifrice containing 0.454% w/w stannous fluoride (1100ppm fluoride)
Dentifrice containing 0.76% sodium monofluorophosphate (1000ppm fluoride)
Time frame: Baseline, Day 14
Schiff sensitivity score was assessed by examiner as participant's response to an evaporative (air) stimulus after the stimulation of each individual tooth. Response of participant was scored using Schiff sensitivity scale range of 0-3; 0=Participant does not respond to air stimulation; 1=Participant responds to air stimulus but does not request discontinuation of stimulus; 2=Participant responds to air stimulus and requests discontinuation or moves from stimulus; 3= Participant responds to stimulus, considers stimulus to be painful, and requests discontinuation of the stimulus. A reduction in Schiff Sensitivity score indicates improvement in sensitivity.
Time frame: Baseline, Day 7
Schiff sensitivity score was assessed by examiner as participant's response to an evaporative (air) stimulus after the stimulation of each individual tooth. Response of participant was scored using Schiff sensitivity scale range of 0-3; 0=Participant does not respond to air stimulation; 1=Participant responds to air stimulus but does not request discontinuation of stimulus; 2=Participant responds to air stimulus and requests discontinuation or moves from stimulus; 3= Participant responds to stimulus, considers stimulus to be painful, and requests discontinuation of the stimulus. A reduction in Schiff Sensitivity score indicates improvement in sensitivity.
Time frame: Baseline, Day 7 and Day 14
Tactile threshold was assessed by examiner using a constant pressure probe (Yeaple probe) which allowed application of a known force to the dentin surface from 10 g to an upper threshold of 80g in increments of 10 g. The tactile threshold is the maximum pressure applied at which participant do not report any pain or discomfort. The tactile threshold for each tooth was determined by asking the participant whether the sensation caused discomfort. The pressure setting at which the participant gave two consecutive 'yes' responses was recorded as the tactile threshold. The higher the tactile threshold, the less sensitive the tooth.
GlaxoSmithKline
Industry
Short Term Clinical Study Investigating the Efficacy of an Occluding Dentifrice in Providing Relief From Dentinal Hypersensitivity
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07317128
Dentin Sensitivity, Stomatognathic Diseases
Wuhan, Hubei, China
View Trial DetailsNCT07352956
Dentin Sensitivity, Stomatognathic Diseases
Chengdu, Sichuan, China
View Trial DetailsNCT06378255
Dentin Sensitivity, Stomatognathic Diseases
Beijing, Beijing Municipality, China
View Trial DetailsNCT06608368
Dentin Sensitivity, Stomatognathic Diseases
Mississauga, Ontario, Canada
View Trial Details