Skip to main content
OpenTrials
Completed

NCT Number: NCT04381234

Strategies for Asymmetrical Triacetate Dialyzer Heparin-Free Effective Hemodialysis

Not all dialysis patients tolerate heparin anticoagulation. Heparin should be avoided in patients at high risk of bleeding. Strategies include saline infusion, citrate-containing dialysate, regional citrate anticoagulation and heparin-coated membranes. We recently studied the combination of a heparin-coated membrane and citrate-containing dialysate, with a success rate of 94% . Although this combination resulted in low rates of clotting, heparin-coated membranes are not ubiquitously available. The quest for easy to perform, safe and affordable heparin-free dialysis is on. Asymmetric cellulose triacetate (ATA) dialyzers have a low degree of platelet contact activation and might be an alternative to heparin-coated dialyzers.

This is a phase II pilot study in maintenance dialysis patients. Study design is a two-arm open-label cross-over study. In Arm 1, patients were dialyzed using a 1.9 m2 ATA membrane (Solacea™-19H, Nipro Corp., Japan) in combination with citrate (1 mM) containing dialysate. In Arm 2, patients were dialyzed with the same 1.9 m2 ATA membrane, in combination with high volume predilution hemodiafiltration. The primary endpoint was the success rate to complete 4 hours of hemodialysis without preterm clotting.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 2

Primary location

University Hospitals Leuven

Leuven, Vlaams-Brabant, 3000, Belgium

About this study

Anticoagulation is one of the supporting pillars of chronic hemodialysis (HD). The optimal anticoagulant regimen provides full anticoagulation of the extracorporeal circuit with minimal systemic effects and comes at an affordable cost. Unfractionated heparin (UFH) has been the standard of care for many years. In several countries, UFH has gradually been replaced by low molecular weight heparins (LMWH). LMWH are easy to use as they can be administered as a bolus injection and reduce membrane fibrin and platelet deposition. Both UFH and LMWH provide adequate anticoagulation of the extracorporeal circuit, at the price of systemic anticoagulation. Apart from bleeding, the administration of unfractionated heparins has also been associated with dyslipidemia, hypoaldosteronism and hyperkalemia, thrombopenia, osteoporosis, pruritus, and hypersensitivity reactions.

Several alternative anticoagulation regimens have been proposed including saline infusion, heparin coating of the dialyzer membrane as well as regional citrate anticoagulation. Regional citrate anticoagulation is performed by infusing citrate into the arterial line of the dialysis tubing to reduce ionized calcium concentrations in order to minimize propagation of the coagulation cascade. Ionized calcium concentrations are restored by calcium supplementation prior to reinfusion of the blood into the patient. The HepZero study suggested that regional citrate anticoagulation is superior to heparin-coated polyacrylonitrile dialyzers (AN69ST; Nephral 300ST, Gambro) and resulted in in significantly greater instantaneous urea nitrogen clearance. While generally safe and adequate, regional citrate anticoagulation requires additional actions during preparatory phase (preparation of citrate and calcium infusion pumps) as well as during the treatment (measurement of ionized calcium).

Recently, acetate-free citrate-containing dialysate concentrates were introduced into clinical practice. Besides the advantages of acetate-free dialysate, this provides a modest local anticoagulant effect inside the dialyzer. Citrate-containing dialysate allowed to reduce heparin dose while maintaining extracorporeal circuit patency and dialyzer clearance. Recently, citrate-containing dialysate and a heparin-coated dialyzer were combined. In one study, non-inferiority to regional citrate anticoagulation was demonstrated

The abovementioned studies demonstrate that hemodialysis without systemic heparinization is feasible. However, such procedures are more cumbersome, require more manpower, additional biochemical testing and/ or more expensive consumables. The aim of the current study is to test two different strategies for systemic heparin-free dialysis with an asymmetrical tri-acetate hemodialyzer.

Trial objectives To evaluate the feasability, safety and adequacy of systemic heparin-free dialysis using an asymmetrical tri-acetate dialyzer membrane, with or without the combination with citrate containing dialysate.

The main objective of the study is to test efficacy of the two study interventions to perform standard duration (i.e. 4 hours) hemodialysis without interruption due to clotting phenomena and without the use of heparin or low molecular weight heparins.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients age 18 years, or over. No maximum age is defined.
  • Providing signed and dated informed consent (ICF)
  • Maintenance dialysis (> 3 months of hemodialysis)
  • 'Standard' dialysis regimen (three dialysis sessions / week, dialysis duration 4 hours)
  • Hemodynamic stability during 4 weeks preceding study period. Hemodynamic instability is defined as any episode of low blood pressure (asymptomatic or symptomatic requiring intervention (bolus fluid infusion, temporarily withholding or reducing ultrafiltration, preterm termination of dialysis session, resuscitation)
  • Hemoglobin 9 - 12 g/dl.

Exclusion criteria

  • Any known medical disorder favoring either bleeding or clotting (e.g. atypical hemolytic uremic syndrome (aHUS), antiphospholipid syndrome, idiopathic thrombocytopenic purpura (ITP), paroxysmal nocturnal hemoglobinuria (PNH))
  • Treatment with a vitamin K antagonist
  • Treatment with any one of the NOACs (apixaban, rivaroxaban, edoxaban, dabigatran)
  • High risk of bleeding according to the criteria of Swartz (12).
  • Patients with a known allergic reaction to asymmetric triacetate
  • Pregnancy

Treatment and study plan

dialyzer

Device

Asymmetric triacetate dialyzer

Other names: Solacea™-19H (Nipro Corp., Japan)

hemodialysis with citrate-containing dialysate

Combination Product

acetate-free dialysate

Other names: Selectbag citrate (1mM citrate, Baxter)

predilution hemodiafiltration

Other

predilution hemodiafiltration

Primary outcomes

  1. clinical patency of the hemodialysis extracorporeal circuit

    Time frame: 4 hours

    clotting of the extracorporeal circuit

Secondary outcomes

  1. Clotting of dialyser

    Time frame: 4 hours

    Semi-quantitative clotting score

  2. dialysis adequacy

    Time frame: 4hours

    single pool Kt/V

  3. Reduction ratio uremic retention solutes

    Time frame: 4 hours

    ratio describing the change in serum concentration over the concentration at the beginning of the dialysis session

Sponsors and collaborators

Lead sponsor

Universitaire Ziekenhuizen KU Leuven

Other

Collaborators

  • NIPRO

Registry information

Official study title

Strategies for Asymmetrical Triacetate Dialyzer

Acronym: SAFE

Important dates

Study start
2018
Primary completion
2019
Study completion
2020
First posted
May 8, 2020
Registry last updated
May 21, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.