University Of Minnesota
Minneapolis, Minnesota, 55455, United States
NCT Number: NCT00869024
The purpose of this study is to determine if the delivery of cells just after implantation of left ventricular assist device will help to improve the pumping function of your heart and minimize heart enlargement in the future.
The cells will be obtained by aspiration or withdrawal of fluid from your bone marrow from your pelvic bone using a needle and syringe. This would not take place until 24-48 hours prior to your planned left ventricular assist device implantation. During the surgery the surgeons will inject the prepared cells that were taken from your bone marrow and inject it into your heart muscle.
This study will test whether receiving your own bone marrow cells directly into your heart will help your heart to recover function after placement of a left ventricular assist device.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Phase 1 / Phase 2
Minneapolis, Minnesota, 55455, United States
Patients who meet the inclusion and exclusion criteria and agree to participate will be enrolled in the study. All the patients will have a baseline EKG, Laboratory tests, 2D ECHO and PET/CT imaging.Day prior to the LVAD implantation all the patients will undergo bone marrow aspiration. Bone marrow aspirate will be processed according to the protocols used by that facility. After processing, the bone marrow mononuclear cells will then be suspended in 2ml of 5% human serum albumin and labeled per the standard protocol of the facility.
Patients will be randomized in a 2:1 fashion either to receive cells or 5% serum albumin. Under general anesthesia using the standard techniques the HeartMate II (LVAD) will be placed. The LVAD will be inserted into the LV apex (with removal of 2 x 2 cm ventricular core). The tissue core will be processed for RNA isolation and morphological analysis. CV surgeon will inject either the cells or placebo directly in to the myocardium in the LAD territory. Ten separate injections will be delivered into the LV free wall (20 X 106 cells / 400 micro lit). The injection sites will be marked with Titanium surgical clips. Subjects will be managed at all times by the current standard of care in this hospital for the patients with an LVAD. Routine postoperative care procedures will be followed with close follow-up for dysrrhythmias or signs of infection.
Tissue sample from the core of the left ventricular apex removed at the time of implantation of LVAD will be compared with the myocardium (marked with the surgical clips) from the explanted heart at the time of transplantation. These samples from the experimental subjects and control hearts will be examined for morphology for interstitial fibrosis, hypertrophy, myocyte diameter and myocytolysis as well as for gene expression using RT-PCR.
Research-related follow-up will take place at weeks 2, 4, 6, 8 and months 6, 12, 18 and 24 after LVAD implant at the Clinical Trial Center of the Cardiology Division at the University of Minnesota. Patients will be examined by the PI or Sub-I at each visit. Follow up data to be obtained at these clinic visits is outlined in the protocol
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
-
Ten separate injections will be delivered into the LV free wall (20 X 106 cells / 400 micro lit).
Time frame: 24 months
Safety as measured by the total number of adverse events per group.
Time frame: baseline, 10 weeks
Change in LAD segments from baseline to 10 weeks. PET scan viability is reported by segment on a scale of 0-4. A score of 0, 1, or 2 are categorized as viable/healthy heart tissue and a score of 3 or 4 are categorized as not viable/scar tissue. No change or better in viability will be reported to determine safety of cell injection. Measurement is reported as number of segment that remained the same or improved were considered "safe" for stem cell injection.
Time frame: 24 months
Number of participants who expired during the study.
Time frame: 10 weeks
LVAD turn-down was completed at 10 weeks. Hemodynamic measurements were taken and reported with nominal LVAD support and then again at peak exercise. LVAD turn-down protocol was followed to ensure safety of patient while turning down their LVAD support. After each turn-down we waited 10 minutes and repeated ECHO, RHC, LVAD parameters, vital signs.
Stopping parameters for turn down:
The number of patients that could be turn-down without meeting stopping rules and were able to exercise were reported per group.
Time frame: 10 weeks
Change in left ventricular dimensions assessed by ECHO at baseline compared to 10 weeks with LVAD turn-down to 6000 RPMs.
Time frame: 24 months
Data collection was insufficient for data analysis. Samples were collected but no histological analysis performed.
University of Minnesota
Other
AsseSsment of Efficacy, Safety and Utility of intRa myocardiAl iNjection of Stem Cells in Patients With End Stage Heart Failure Undergoing LVAD Implantation (ASSURANCE)
Acronym: ASSURANCE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03446651
Cardiovascular Diseases, Heart Diseases
New Haven, Connecticut, United States
View Trial DetailsNCT05806606
Behavior, Cardiovascular Diseases
Hong Kong
View Trial DetailsNCT06847438
Cardiovascular Diseases, Heart Diseases
Atlanta, Georgia, United States
View Trial DetailsNCT07721909
Cardiovascular Diseases, Heart Diseases
Muscat, Oman
View Trial Details