CHU Amiens Picardie
Amiens, France
NCT Number: NCT05104606
Acute cor pulmonale is one of deadly complications of mechanically ventilated acute respiratory distress syndrome (ARDS), which can lead to right ventricular dysfunction and worsen the hemodynamics of the patient. For several years, transthoracic (TTE) and transesophageal echocardiography (TEE) have replaced the pulmonary artery catheter to monitor cardiac function reliably and non-invasively.
Speckle tracking is an echocardiographic technique that allows a two-dimensional strain (2D) analysis of right ventricular systolic function. Right ventricular global strain (RVGLS) is a strain parameter, allowing an early and more accurate diagnosis of right ventricular dysfunction than conventional parameters.
This project will consist of performing TTE and TEE measurements at H0, 30min, H1, H2, and H24 after iNO administration in patient with ARDS under mechanical ventilation. The patient will be declared responder to iNO, if there is an increase of more than 20% of the PaO2/FiO2. 30 minutes after a dose of 10ppm of iNO.
This study is active but is not currently recruiting participants.
Notify Me18 year and older
All sexes
Interventional
Not applicable
Amiens, France
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The intervention within the framework of the protocol will consist, for the needs of the study, in performing 2 TEE and 5 TTE in 24 hours after
For TEE:
For TTE:
Time frame: 30 minutes
Systolic function will be assessed with "in speckle tracking RV" in the presence or not of a response to iNO 30 minutes after its administration, Systolic function will be assessed with "in speckle tracking RV" in patients with moderate to severe ARDS under mechanical ventilation.
Time frame: at 1 hour
Right ventricular function is assessed by speckle tracking at 1 hour after iNO administration in iNO responders
Time frame: at 1 hour
Right ventricular function is assessed by speckle tracking at 1 hour after iNO administration in iNO nonresponders
Time frame: at 2 hours
Right ventricular function is assessed by speckle tracking at 2 hours after iNO administration in iNO responders
Time frame: at 2 hours
Right ventricular function is assessed by speckle tracking at 2 hours after iNO administration in iNO nonresponders
Time frame: at 24 hours
Right ventricular function is assessed by speckle tracking at 24 hours after iNO administration in iNO responders
Time frame: at 24 hours
Right ventricular function is assessed by speckle tracking at 24 hours after iNO administration in iNO nonresponders
Centre Hospitalier Universitaire, Amiens
Other
Speckle Tracking Evaluation of the Impact of Inhaled Nitric Oxide on the Right Ventricle in Acute Respiratory Distress Syndrome
Acronym: NOSPECKLE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04401111
ARDS, COVID
Nice, France
View Trial DetailsNCT07370610
ARDS, Lung Diseases
Shanghai, Shanghai Municipality, China
View Trial DetailsNCT06737432
ARDS, Lung Diseases
Galveston, Texas, United States
View Trial DetailsNCT06812949
ARDS
Brussels, Brussels Capital, Belgium
View Trial Details