Bracco Diagnostics Inc
Princeton, New Jersey, 08540, United States
NCT Number: NCT00788697
The purpose of this study is to demonstrate the superiority of SonoVue®-enhanced ultrasound versus unenhanced ultrasound for characterization of Focal Liver Lesions using final diagnosis based on histology or combined imaging/clinical data as truth standard.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 3
Princeton, New Jersey, 08540, United States
Unit of analysis for the outcome measures was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Contrast-enhanced ultrasound (CE-US) examination of the target lesion. Drug: SonoVue® Dose of 2.4 mL bolus injection administered intravenously. Maximum of 2 injections (4.8 mL)
Other names: sulfur hexafluoride microbubbles
-Unenhanced: Gray scale and Doppler (color or power imaging) ultrasound investigations of the target lesion. Drug: None
Time frame: 24 hours to 6 months
Sensitivity of SonoVue-enhanced ultrasound (SonoVue CE-US) versus unenhanced ultrasound (UE-US) for characterization of malignant focal liver lesions (FLLs), using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the Intent-to-Diagnose (ITD) population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
True positive: subject with a target lesion characterized as malignant by both ultrasonography and the truth standard.
Truth standard: contrast-enhanced computed tomography (CE CT) and /or contrast-enhanced magnetic resonance imaging (CE-MRI) examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true positive lesions/number of malignant lesions per truth standard) x 100.
Time frame: 24 hours to 6 months
Specificity of SonoVue-enhanced versus unenhanced ultrasound for characterization of benign FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
True negative: subject with a target lesion characterized as benign by both ultrasonography and the truth standard.
Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true negative lesions/number of benign lesions per truth standard) x 100.
Time frame: 24 hours to 6 months
The Accuracy of SonoVue-enhanced versus unenhanced ultrasound for characterization of malignant and benign FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
True positive: subject with a target lesion characterized as malignant by both ultrasonography and the truth standard.
True negative: subject with a target lesion characterized as benign by both ultrasonography and the truth standard.
Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true positive and true negative lesions/number of total lesions per truth standard) x 100.
Time frame: 24 hours to 6 months
Positive Predictive Value of SonoVue-enhanced versus unenhanced ultrasound for characterization of FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
True positive: subject with a target lesion characterized as malignant by both ultrasonography and the truth standard.
Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true positive lesions/number of malignant lesions per ultrasound) x 100.
Time frame: 24 hours to 6 months
Negative Predictive Value of SonoVue-enhanced versus unenhanced ultrasound for characterization of FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
True negative: subject with a target lesion characterized as benign by both ultrasonography and the truth standard.
Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true negative lesions/number of benign lesions per ultrasound) x 100.
Time frame: 24 hours to 6 months
SonoVue-enhanced versus unenhanced ultrasound for specific diagnosis of malignant FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of correctly characterized lesions/number of lesions per truth standard) x 100.
Time frame: 24 hours to 6 months
SonoVue-enhanced versus unenhanced ultrasound for specific diagnosis of benign FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.
Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of correctly characterized lesions/number of lesions per truth standard) x 100.
Time frame: 24 hours to 6 months
Inter-reader agreement of assessment of malignant or benign by unenhanced and SonoVue-enhanced ultrasonography separately. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized. Computation for the percentage agreement within two categories: "3 out of 3 readers agree" and "2 out of 3 readers agree".
Bracco Diagnostics, Inc
Industry
Characterization of Focal Liver Lesions With SONOVUE®-Enhanced Ultrasound Imaging: A Phase III, Intrapatient Comparative Study Versus Un-enhanced Ultrasound Imaging Using Histology or Combined Imaging/Clinical Data as Truth Standard
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07719933
Digestive System Diseases, Digestive System Neoplasms
Guangzhou, Guangdong, China
View Trial DetailsNCT04962958
Adenocarcinoma, Antimetabolites
Guangzhou, Guangdong, China
View Trial DetailsNCT07192172
Adenocarcinoma, Carcinoma
Seoul, South Korea
View Trial DetailsNCT07407257
Adenocarcinoma, Carcinoma
Ljubljana, Slovenia
View Trial Details