Imperial College Healthcare Trust; Hammersmith Hospital
London, W12 0HS, United Kingdom
Location status: Recruiting
NCT Number: NCT07009834
Conduction system pacing is a new way of stimulating the heart using pacemaker wires. Traditional pacemakers stimulate the heart muscle which causes disordered heart beats: the walls of the heart move at different times. This wears down the heart over time.
Conduction system pacemakers stimulate the heart's electrical system directly producing natural heart beats that are much less disordered. Unfortunately, these pacemakers can only be implanted by a small group of experts at specialised centres with specialist equipment. This study aims to allow conduction system pacemakers to be offered to any patient at any hospital by simplifying the process of inserting the pacemaker wires and the improving the pacemaker's ability to interpret electrical traces.
Firstly, the best locations in the heart for conduction system pacemaker wires using specialised electrical traces, MRI and ultrasound scans will be identified. Features that can be seen on X-ray to guide doctors to these locations will then be identified. Secondly, the investigators will collect electrical information from the pacemaker wires and additional electrical traces to develop an algorithm that can make the interpretation the electrical traces more accurate.
Interested in participating?
Request Info18 year–100 year
All sexes
Observational
London, W12 0HS, United Kingdom
Location status: Recruiting
Study A:
100 patients will be prospectively recruited. These patients will be further divided into a derivation and validation group. The derivation group will consist of the first fifty patients recruited (patients 1-50) and the validation group will consist the second fifty patients recruited (patients 51-100).
All 100 patients will have an indication for pacemaker insertion and will undergo a conduction system pacemaker implant.
The derivation group will undergo the research protocol which will include additional measurements from:
Non invasive mapping will also be performed in a subgroup of patients with ECGi, where the participants will wear a 252 electrode ECG vest during the procedure. These patients will undergo a pre-procedural CT scan with the vest.
Additional venous access from the femoral vein in the groin will be sought for patients undergoing intracardiac echocardiography.
A further 50 patients will be prospectively recruited that will make up the validation cohort for Study A. These patients will undergo a conduction system pacemaker as standard clinical practice. The step-by-step algorithm will be prospectively derived from the above to implant the conduction system lead using standard equipment alone; fluoroscopy, PSA and 12-lead ECG. The success rate, conduction system capture threshold, procedure time and fluoroscopy time will be assessed. Although all operators will be highly experienced device implanters, these implants will include operators who are new to conduction system lead implantation.
Study B:
In patients 1-50 undergoing implantation of conduction system pacemakers, 2-lead surface ECG alongside conventional lead data will be collected. A surface 12-lead ECG will be collected as well. The patients will undergo the standard pacing manoeuvres for conduction system pacing. The patient will be paced using the PSA and a 12-lead ECG and 2-lead ECG will be collected via Bard, a computer software that is able to collect highly accurate ECG traces of the heart using mapping catheters placed inside the heart and the surface ECG.
Prospective data from 200 patients with a chronic conduction system lead implant under device follow-up to obtain EGM, 12 -lead ECG and the 2-lead ECG recordings of multiple pacing and sensing configurations will also be collected. These patients will be attending for routine appointments. The pacing and sensing configurations are undertaken as part of routine checks
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: From enrollment until 6 months after recruitment of last patient
Time frame: From enrollment until 6 months after recruitment of last patient
Time frame: From enrolment to until completion of PPM insertion of the last patient recruited into Study A (patient 100); average total of 3 years
Time frame: From enrolment to until completion of PPM insertion of the last patient recruited into Study A (patient 100); average total of 3 years
Time frame: From enrollment until 6 months after recruitment of last patient
Threshold is measured through the device, looking to achieve the minimum energy (in V) required to safely and reliably capture the cardiac tissue target. In this outcome, the investigators will compare the minimum threshold required to achieve capture of conduction system pacing to that of conventional right ventricular pacing and asses if this the same, higher or lower.
Time frame: From enrollment until 6 months after recruitment of last patient
Time frame: From enrollment until 6 months after recruitment of last patient
Device battery time is given upon device interrogation and is dependent on percentage of the time the patient is paced and the energy delivered. Battery life will increase if less energy is required. The investigators will assess if there is a increase in days or months in the battery life of the pacemaker with introduction of the novel algorithm.
Contact information is provided by the study sponsor or research team.
Imperial College London
Other
Acronym: CSA
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07276490
Arrhythmias, Cardiac, Atrioventricular Block
Tallinn, Harju, Estonia
View Trial DetailsNCT07492979
Cardiac Resynchronisation Therapy (CRT), Cardiovascular Diseases
Aarhus, Denmark
View Trial DetailsNCT06241651
Biventricular Pacing, Cardiac Resynchronization Therapy
Nanjing, Jiangsu, China
View Trial DetailsNCT07217392
Arrhythmias, Cardiac, Atrial Fibrillation
Rio de Janeiro, Brazil
View Trial Details