Oregon Health and Science University
Portland, Oregon, 97239, United States
NCT Number: NCT03528174
The study described within this protocol is designed to test a single hormone closed-loop algorithm for managing blood glucose in type 1 diabetes using insulin only and a new device for measuring glucose continuously in the immediate vicinity of subcutaneous insulin delivery. Subjects will undergo one all day closed loop study using insulin only. The closed loop insulin only system includes a Dexcom G5 transmitter, a Nexus 5 smart phone and two Tandem tslim pumps connected to two Pacific Diabetes Technologies glucose sensing cannulas. The closed loop system will be started after G5 2 hour sensor start-up with an IV catheter for frequent blood withdrawal for 10 hours.
Looking for future studies?
Notify Me21 year–65 year
All sexes
Interventional
Not applicable
Portland, Oregon, 97239, United States
Subjects will undergo one 12 hour inpatient study. During this intervention visit, subjects will wear the single hormone closed loop system which includes two t:slim insulin pumps to deliver insulin or saline through two investigational PDT glucose sensing cannulas, and a Dexcom G5 CGM to measure glucose. The subject will come to the research center at approximately 7am for the inpatient visit. The Dexcom G5 sensor and PDT glucose sensing cannulas will be placed after arrival. An 18-22 gauge IV catheter will be placed for blood sampling every 15 minutes after sensor warm-up is complete for measuring blood glucose concentration. After a 2 hour warm-up period for the G5 sensor, glucose will be controlled using the FMPD single hormone mode. The single hormone mode of the controller determines insulin delivery rates based on proportional and derivative error through one t:slim insulin pump. The second t:slim insulin pump will deliver normal saline at the same delivery rates as the insulin. Subjects will eat breakfast and lunch at approximately 11 am and 3 pm respectively. Subjects will have the ability to complete light exercise on a treadmill. The closed loop system will be stopped at approximately 6pm with removal of all devices.
During the study, the subject will wear one subcutaneous DexcomTM G5 continuous glucose monitoring (CGM) system. The CGM system will provide sensed glucose data every 5 minutes. The accuracy of the sensed data will be obtained by reference measurements of two YSI venous blood glucose values to calibrate the sensor at the beginning of the closed loop study. Sensed glucose data will be wirelessly transmitted via Bluetooth Low Energy (BTLE) from the Dexcom G5 transmitter to the Nexus 5 master controller every five minutes. The controller is a Google Nexus 5 phone. The smart phone will wirelessly communicate via BTLE to two Tandem t:slim insulin pumps, one for automated insulin delivery and one of automated saline delivery.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
This intervention is a single hormone closed loop system including a Nexus 5 smart phone, two tslim insulin pumps, a Dexcom G5 CGM and two PDT glucose sensing cannulas that together make up a new experimental, investigational device system. The algorithm included in the APC is an automated version of the Fading Memory Proportional Derivative (FMPD) insulin and glucagon control algorithm.
An integrated combination CGM/insulin infusion system
Time frame: up to 10 hours
Assess the mean absolute relative difference for the PDT CGM/insulin infusion system based on all reference YSI venous blood glucose values.
Time frame: up to 10 hours
Assess the percent of time with sensed glucose between 70-180 mg/dl based on the Dexcom G5 CGM sensor values for all subjects.
Time frame: up to 10 hours
Assess the percent of time with sensed glucose less than 70 mg/dl based on the Dexcom G5 CGM sensor values for all subjects.
Time frame: up to 10 hours
Assess the percent of time with sensed glucose less than 54 mg/dl based on the Dexcom G5 CGM sensor values for all subjects.
Time frame: up to 10 hours
Assess the percent of time with sensed glucose greater than 250 mg/dl based on the Dexcom G5 CGM sensor values for all subjects.
Time frame: up to 10 hours
Assess the average sensor glucose based on the Dexcom G5 CGM sensor values.
Time frame: up to 10 hours
Assess the average number of carbohydrate treatments per study defined as 15 or 20 grams of carbohydrates.
Time frame: up to 10 hours
Assess the average amount of insulin delivered per study in units/kg.
Time frame: 15 minutes post insertion
Assess the average score on the visual analog scale at 15 minutes after insertion of the PDT glucose sensor. This scale will be used to measure sensor site discomfort from the PDT glucose sensing cannula. The subject completes the visual analog scale by drawing a single vertical line through a 100 mm line corresponding to the perceived intensity (severity) of discomfort from the insertion of the sensors. Subjects will be instructed to mark their line starting on the left side over to the right side. If subjects are feeling no discomfort, they would circle the vertical line on the left end of the scale. If subjects are currently feeling the worst discomfort possible, they would circle the vertical line on the right side of the scale. One staff member will measure all scales and document score as a measurement of 0-100.
Time frame: 120 minutes post insertion
Assess the average score on the visual analog scale at 120 minutes after insertion of the PDT glucose sensor.This scale will be used to measure sensor site discomfort from the PDT glucose sensing cannula. The subject completes the visual analog scale by drawing a single vertical line through a 100 mm line corresponding to the perceived intensity (severity) of discomfort since the devices were inserted. Subjects will be instructed to mark their line starting on the left side to the right side. If subjects are feeling no discomfort, they would circle the vertical line on the left end of the scale. If subjects are currently feeling the worst discomfort possible, they would circle the vertical line on the right side of the scale. One staff member will measure all scales and document score as a measurement of 0-100.
Time frame: End of 10 hour study
Assess the average score on the visual analog scale at the end of the study. This scale will be used to measure sensor site discomfort from the PDT glucose sensing cannula. The subject completes the visual analog scale by drawing a single vertical line through a 100 mm line corresponding to the perceived intensity (severity) of discomfort since the devices were inserted. Subjects will be instructed to mark their line starting on the left side to the right side. If subjects are feeling no discomfort, they would circle the vertical line on the left end of the scale. If subjects are currently feeling the worst discomfort possible, they would circle the vertical line on the right side of the scale. One staff member will measure all scales and document score as a measurement of 0-100.
Time frame: End of 10 hour study
Assess the average score on the Draize scale at the end of the study of the PDT glucose sensor. The investigator discharging the subject will inspect each PDT glucose sensing cannula insertion site and rate the level of redness (erythema) and swelling (edema). Both the left and right insertion sites will be inspected. Erythema will be measured from 0-4. A score of 0 indicates no erythema, a score of 1 indicates very slight, barely perceptible erythema, a score of 2 indicates well defined erythema, a score of 3 indicates moderate erythema, and a score of 4 indicates severe erythema, beet redness to slight eschar formation. Edema will be measured from a score of 0-4. A score of 0 indicates no edema, a score of 1 indicates very slight, barely perceptible edema, a score of 2 indicates well defined edema, a score of 3 indicates moderate edema, raised approximately 1 mm, and a score of 4 indicates severe edema, raised greater than 1 mm and beyond exposure area.
Time frame: end of 10 hour study
Assess the average score on the Draize scale at the end of the study of the PDT glucose sensor. The investigator discharging the subject will inspect each PDT glucose sensing cannula insertion site and rate the level of redness (erythema) and swelling (edema). Both the left and right insertion sites will be inspected. Erythema will be measured from 0-4. A score of 0 indicates no erythema, a score of 1 indicates very slight, barely perceptible erythema, a score of 2 indicates well defined erythema, a score of 3 indicates moderate erythema, and a score of 4 indicates severe erythema, beet redness to slight eschar formation. Edema will be measured from a score of 0-4. A score of 0 indicates no edema, a score of 1 indicates very slight, barely perceptible edema, a score of 2 indicates well defined edema, a score of 3 indicates moderate edema, raised approximately 1 mm, and a score of 4 indicates severe edema, raised greater than 1 mm and beyond exposure area.
Time frame: End of 10 hour study
Assess the average score on the Draize scale at the end of the study of the PDT glucose sensor. The investigator discharging the subject will inspect each PDT glucose sensing cannula insertion site and rate the level of redness (erythema) and swelling (edema). Both the left and right insertion sites will be inspected. Erythema will be measured from 0-4. A score of 0 indicates no erythema, a score of 1 indicates very slight, barely perceptible erythema, a score of 2 indicates well defined erythema, a score of 3 indicates moderate erythema, and a score of 4 indicates severe erythema, beet redness to slight eschar formation. Edema will be measured from a score of 0-4. A score of 0 indicates no edema, a score of 1 indicates very slight, barely perceptible edema, a score of 2 indicates well defined edema, a score of 3 indicates moderate edema, raised approximately 1 mm, and a score of 4 indicates severe edema, raised greater than 1 mm and beyond exposure area.
Oregon Health and Science University
Other
Assessment of a Novel Sensing Catheter During Automated Insulin Delivery in Patients With Type 1 Diabetes
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07696039
Autoimmune Diseases, Diabetes Mellitus
Bergamo, Italy
View Trial DetailsNCT03263494
Autoimmune Diseases, Diabetes Mellitus
Los Angeles, California, United States
View Trial DetailsNCT07090824
Autoimmune Diseases, Diabetes Mellitus
Palo Alto, California, United States
View Trial DetailsNCT05211479
Adolescent, Anxiety Disorders
Yalova, Turkey (Türkiye)
View Trial Details