faculty of dentistry, kafrelsheikh University
Kafr ash Shaykh, Kafrelsheikh, 214312, Egypt
NCT Number: NCT06313229
The purpose of this study was to report the clinical and radiographical outcomes of using autogenous cortical bone plates combined with sticky allogenic bone graft for augmenting maxillary anterior atrophic combined horizontal and vertical ridge defects with simultaneous versus staged implant placement.
This study is active but is not currently recruiting participants.
20 year–40 year
All sexes
Interventional
Not applicable
Kafr ash Shaykh, Kafrelsheikh, 214312, Egypt
Sufficient alveolar ridge is a prerequisite for successful implant stability, atrophic ridges defects make the placement of regular implants challenging. A variety of materials and surgical techniques are available for bone augmentation procedures prior implant placement. The present study evaluated the effect of sticky allogenic bone graft for the horizontal and vertical ridge augmentation with simultaneous implant placement using autogenous cortical bone plates in maxillary anterior atrophic ridge defects.
Forty-two patients, with severe maxillary anterior horizontal and vertical atrophic ridge deficiencies were randomly assigned to two groups: staged approach group and simultaneous implant placement group. The two groups were grafted using bone plated buccally and palatally and the defect between plates was grafted by sticky allogenic bone graft. Radiographic examination was performed immediately before bone grafting procedure and at 6, 12 months postoperatively, to evaluate the change of bone width and height.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
the deficient ridge was grafted first followed by implant placement after 6-monthes
the deficient ridge was grafted and followed by implant placement simultaneously
Time frame: 12-month.
The implant stability was recorded using Osstell TM. Following implant insertion, SQI readings were taken immediately, then again after six and twelve months.
Time frame: 12-month.
The HBD alterations were assessed by measuring horizontal spacing between the external edges of labial and palatal bony plates at a level 2mm apical of the fixture platform.
Time frame: 12-month.
For consistent measurement of the PBD, 1-mm-diameter Region of interest (RI) was selected and traced 1.2 mm distant from the fixture on the cross-sectional slices followed by counting the threshold pixels inside the RI.
Kafrelsheikh University
Other
Simultaneous Versus Staged Implant Placement With Vertical and Horizontal Bone Augmentation Using Autogenous Cortical Bone Plates Combined With a Mixture of Platelet-rich Fibrin and Allobone Grafts.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06887595
Alveolar Bone Loss, Bone Diseases
Kafr ash Shaykh, Kafrelsheikh, Egypt
View Trial DetailsNCT07011303
Alveolar Bone Loss, Bone Diseases
Tokat Province, Turkey (Türkiye)
View Trial DetailsNCT04572490
Alveolar Bone Loss, Bone Diseases
Kütahya, Turkey (Türkiye)
View Trial DetailsNCT07375004
Alveolar Bone Loss, Bone Diseases
Baghdad, Iraq
View Trial Details