Serum Biomarkers in Diagnosis of Mesothelioma

In this study, the investigators analyzed the efficiencies of hyaluronan, osteopontin, C-ERC/mesothelin, N-ERC/mesothelin and syndecan-1 serum levels, both individually and in combination, in distinguishing malignant pleural mesothelioma patients from patients with metastatic malignant pleural diseases, benign pleural diseases, and benign asbestos pleurisy.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–85 year

Sex eligibility

All sexes

Study type

Observational

Primary location

ESOGU Lung and Pleural Cancer Application and Research Center

Eskişehir, 260240, Turkey (Türkiye)

About this study

In the year 2002, a database for the pleural diseases was constructed to be prospectively filled in the department. The findings, outcome features and characteristics of follow-up for all cases with pleural diseases have been recorded in this database. The patient data, including epidemiological characteristics, smoking status, history of other diseases and co-morbid conditions, previous asbestos exposure, medications and additional physical and radiological examination findings, including computed tomography scans, both serum and pleural fluid laboratory investigational data and indications of invasive procedures, were recorded in the database mentioned above. The methods employed in the diagnosis of patients; any complications; characteristics such as the stages of diseases, treatments, and course of treatments; and results were also recorded in the database. From the date of the first database establishment, a "tissue, blood, serum, and fluid specimen bank" was constructed; tissue, blood, serum and pleural fluid samples of patients, which had been taken at the beginning of diagnosis process, were stored in this bank at -80°C. The blood, serum, and pleural fluid samples of patients were stored during the diagnosis process, and if conducted, pleural tissue samples taken during invasive procedures were also stocked.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients with a definite pleural diseases
  • Age more than 18 year-old, less than 85 year-old.
  • Willingness to participate in the study.

Exclusion criteria

  • Patients with undiagnosed pleural diseases.
  • Age less than 18 year-old or more than 85 year-old.

Treatment and study plan

Mesothelin, hyaluronan, osteopontin, syndecan-1

Biological

We compere the serum levels of the tumor markers in patients with pleural diseases according to the groups for the diagnosis and differential diagnosis of the diseases.

Other names: N-ERC/mesotehlin,, C-ERC/mesotehlin, Osteopontin, Hyaluronan, Syndecan-1

Primary outcomes

  1. Serum N-ERC/mesothelin, C-ERC/mesothelin, hyaluronan, osteopontin and syndecan -1 level in the patients with mesothelioma, metastatic malignant pleural diseases, benign pleural diseases, and benign asbestos pleurisy.

    Time frame: From January 2004 to December 2010

    The levels of N-ERC/mesothelin, C-ERC/mesothelin, hyaluronan, osteopontin, and syndecan-1 in the serum samples were established by Enzyme-Linked Immunosorbent Assays (ELISA) at the Division of Pathology, Department of LABMED, Karolinska Institute, Stockholm, Sweden.

    All analyses were performed in duplicate by researchers who were unaware of the patient diagnoses. The human N-ERC/mesothelin and osteopontin. ELISA kits were supplied by Immuno-Biological Laboratories Co. Ltd. Japan; the C-ERC/mesothelin ELISA kit was supplied by (MESOMARK™) FDI Fujirebio Diagnostics, Inc.; the hyaluronan ELISA kit (Ref. 029-001) was supplied by Corgenix company; and the syndecan-1 ELISA kit (catalog no. 950.640.096) was supplied by the Diaclone company. Analyses were conducted using a sensitivity TM XS Microplate Sample Processor manufactured by Bio-Tek Instruments Inc (Vermont, USA) in accordance with the manufacturer's instructions. The C-ERC/mesothelin levels were determined at nanomolar levels due

Sponsors and collaborators

Lead sponsor

Eskisehir Osmangazi University

Other

Registry information

Official study title

PREDICTING MALIGNANT MESOTHELIOMA BY ANALYZING HYALURONAN, OSTEOPONTIN, C-ERC/MESOTHELIN, N-ERC/MESOTHELIN AND SYNDECAN-1 SERUM LEVELS

Important dates

Study start
2004
Primary completion
2010
Study completion
2013
First posted
Jan 7, 2014
Registry last updated
Jan 7, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.