[W]-Eye clinic
Poznan, 61-048, Poland
NCT Number: NCT03689088
Glaucoma is characterized by irreversible vision loss through the progressive death of optic nerve fibers unless timely diagnosis and adequate treatment are provided. Medical therapy is aimed at lowering intraocular pressure (IOP) below a clinically determined target level in order to prevent or slow glaucoma progression. IOP is known to vary with the time of day as well as with daily activities.
The current way of assessing nycthemeral IOP fluctuation is to perform repeated discrete tonometry measurements, allowing only snapshot and non-continuous measurements once per hour in the best cases. The procedure is cumbersome, expensive, inconvenient (disturbed sleep cycle as patient is awoken for nocturnal/sleep period measurements) and may not detect crucial IOP values in time.
Sensimed AG has developed a new contact lens (CL)-based device intended to continuously measure IOP over 24 hours. The objective of this study is to investigate the use of device for 24-hour IOP monitoring in healthy subjects and glaucoma patients.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Poznan, 61-048, Poland
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Goldfish will be placed in the eye for 24h monitoring
Fellow eye will be measured by tonometry
Time frame: 24 hours
IOP will be measured using tonometry in the fellow eye and compared to IOP measured in the Goldfish eye with the Goldfish device
Time frame: 24 hours
Percentage of subject completing the session will be calculated at the end of the study
Time frame: 24 hours
Tolerability of the Goldfish lens will be subjectively evaluated before and after GF wear using a visual analogue scale from 0 (no discomfort) to 100 (severe discomfort) mm
Time frame: 24 hours
Percentage of valid measurement will be calculated at the end of each monitoring session
Time frame: 24 hours
OPA will be extracted from the Goldfish signal in the Goldfish eye and measured by tonometry in the fellow eye. Both IOP and OPA measurement will be compared between fellow eyes
Time frame: 24 hours
IOP signal acquired with Goldfish will be compared to BP signal assessed with a BP holter
Sensimed AG
Industry
A Prospective Pilot Study Investigating the Use of a Sensing Contact Lens-based Device for 24-hour Monitoring of Intraocular Pressure in Healthy Subjects and Patients With Open Angle Glaucoma
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05236439
Eye Diseases, Glaucoma
Yerevan, Armenia
View Trial DetailsNCT05325996
Eye Diseases, Glaucoma
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT04872348
Eye Diseases, Glaucoma
Atlanta, Georgia, United States
View Trial DetailsNCT04944290
Eye Diseases, Glaucoma
Winston-Salem, North Carolina, United States
View Trial Details