The SARA (Self Abrading Rapidly Applied) electrode will speed EEG patient hookup by combining multiple steps that burden conventional EEG procedures into one. The investigators believe that the proposed system will reduce patient hookup time by more than 50% (from 40 to 20 minutes) with additional time savings on cleanup. Reducing the hookup time required for the EEG recording will make EEG more feasible in time critical situations and will improve patient care and service. The clinical testing in Phase II will investigate patient acceptance, clinician acceptance, time savings, and signal quality for 3 different environments: the large hospital institution, a small rural hospital setting and in an emergency department.
Looking for future studies?
Notify Me12 year and older
All sexes
Interventional
Not applicable
Cleveland, Ohio, 44109, United States
The SARA (Self Abrading Rapidly Applied) electrode will speed EEG patient hookup by combining multiple steps that burden conventional EEG procedures into one. This proposed single-use electrode will consist of a Snap Top, Ag/AgCl Snap Conductor, Conductive Adhesive, and Abrader Tines in a custom molded housing and packed on a backing sheet. After removing the backing, the technician simply parts the hair with one hand and with the other hand rubs the electrode back and forth and then presses the electrode into position on the scalp. The proposed system combines the cumbersome and time-consuming skin preparation, electrode preparation and electrode fixation into one easy step. The investigators believe that the proposed system will reduce patient hookup time by more than 50% (from 40 to 20 minutes) with additional time savings on cleanup. Reducing the hookup time required for the EEG recording will make EEG more feasible in time critical situations and will improve patient care and service.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: up to 1 hour
The time it takes in seconds to properly place the SARA electrodes and standard gold cup electrodes will be recorded and compared.
Cleveland Medical Devices Inc
Industry
Self Abrading Rapidly Applied (SARA) Electrode Phase II
Acronym: SARA
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.