NCT Number: NCT07689279

Selection of Transcatheter Heart vaLve With Intermediate Sizing in Patients With Severe Aortic Stenosis Treated With Transcatheter Aortic Valve Replacement

Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Two types of transcatheter heart valves, balloon-expandable and self-expanding, exhibit distinct hemodynamic and structural characteristics that influence procedural strategy and long-term durability. Accurate valve sizing is crucial for procedural success, as both undersizing and oversizing are associated with procedural complications, including aortic regurgitation, conduction disorders, valve embolization, annular rupture, and increased leaflet stress which may impair long-term durability. However, optimal annular sizing remains challenging due to the complex three-dimensional anatomy of the aortic annulus, which is oval, crown-shaped, dynamically deforming, and variably oriented. These anatomical features often lead to "grey zones" in clinical sizing charts, resulting in so-called borderline annuli in which the measured annular dimensions may indicate two suitable valve sizes. Borderline annuli are frequently encountered in patients undergoing TAVI with self-expanding valves (i.e., Evolut transcatheter heart valve series) due to a limited number of sizes (23, 26, 29 and 34 mm). Consequently, under- or oversizing of self-expanding valves is often required. However, sizing of transcatheter heart valves in borderline annuli is associated with a greater likelihood of procedural complications, higher rates of aortic regurgitation, and higher transvalvular gradients.9,11 New generation balloon-expandable valves (i.e., Myval transcatheter heart valve series) are introduced with intermediate (21.5, 24.5, 27.5 mm) and extra-large (30.5, 32 mm) valve sizes that are not available for the Evolut platform. These additional size ranges potentially offer more precise annular sizing, reducing the need for under- or oversizing and improving short- and long-term hemodynamic performance.

The SELECT TAVR trial will evaluate whether the expanded size range of the balloon-expandable Myval transcatheter heart valves is noninferior compared to the self-expanding Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days.

Objectives:

The primary objective of the current trial is to determine whether the Myval transcatheter heart valve series is noninferior to the Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days Secondary objectives: The secondary objectives of the current trial include: 1) Hemodynamic performance as assessed by invasive hemodynamic parameters as well as by transthoracic echocardiography at 30 days (+2 months), and longer-term follow-up; and 2) Long-term clinical outcomes with follow-up up to 5 years.

Study design:

The proposed SELECT TAVR trial is an investigator-initiated, open-label, multicenter, randomized controlled, noninferiority trial with blind end point adjudication.

Study population:

The SELECT TAVR trial will focus on patients referred for TAVI in whom CT-derived annular dimensions fall within borderline annulus ranges

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

A potential participant is deemed eligible for trial participation if the following criteria are met:

  • TAVI as decided by local multidisciplinary heart team
  • CT-derived annular perimeters fall within the following ranges:
  • 55.5 - 57.5 mm
  • 61.0 - 64.5 mm
  • 70.5 - 74.0 mm
  • 79.5 - 84.0 mm
  • 92.0 - 96.0 mm
  • Written informed consent

Exclusion criteria

A potential participant will be excluded from trial participation in case of inability to provide informed consent.

Treatment and study plan

transcatheter heart valve

Device

All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis. This is a routine medical procedure, not a study intervention.

Other names: TAVI, TAVR, Transcatheter aortic valve implantation, Transcatheter aortic valve replacement

Primary outcomes

  1. A composite safety end point as per VARC-3 guidelines

    Time frame: 30 days

    A composite safety end point as per VARC-3 guidelines that consists of all-cause mortality, all stroke, type 2 to 4 bleeding, major vascular access-related or cardiac structural complications, acute kidney injury stage 3 to 4, moderate or severe aortic regurgitation, new permanent pacemaker implantation due to conduction abnormalities, surgery or intervention related to the device at 30 days after TAVI as defined in accordance with criteria stated by the third Valve Academic Research Consortium (VARC-3).

Secondary outcomes

  1. A composite safety endpoint as per VARC-3 guidelines

    Time frame: Annually, up to 5 years

    All clinical end points will be assessed after TAVI

  2. Hemodynamic performance

    Time frame: At 30 days (+2 months) and at 1, 3 and 5 years

    Hemodynamic performance will be assessed by transthoracic echocardiography

  3. Patient-reported outcomes, using the Kansas City Cardiomyopathy Questionnaire (KCCQ)-12

    Time frame: Yearly, up to 5 years

Study contacts

Contact information is provided by the study sponsor or research team.

Elsbeth C. Noppers, MD

CONTACT

[email protected]

+31 (0) 20 566 2893

Sponsors and collaborators

Lead sponsor

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)

Other

Registry information

Acronym: SELECT TAVR

Important dates

Study start
2026
Primary completion
2033
Study completion
2033
First posted
Jul 8, 2026
Registry last updated
Jul 8, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.