Skip to main content
OpenTrials
Completed

NCT Number: NCT03634865

Screw Lengths in Radius Volar Plates

Background Fractures of the distal radius are among the most common. Major complications, including irritation and rupture of the extensor tendons, may occur if epiphyseal screws of inappropriate length are used.

Questions/Purposes The main objective of the present study was to determine whether the optimal epiphyseal screw length can be determined by reference to the diaphyseal screw length.

Methods Forty CT scans were semi-automatically segmented. A 3D model of the volar plate was affixed to each distal radius with simulation. The maximum lengths of the diaphyseal screws, as well as the four distal epiphyseal screws, were measured. Linear regression analysis was performed.

Completed

Looking for future studies?

Notify Me

Key information

Age range

17 year–85 year

Sex eligibility

All sexes

Study type

Observational

Primary location

CHUR de Brest

Brest, 29609, France

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • All CT-scans available in our database

Exclusion criteria

  • Any pathology that could affect the radius morphology
  • Refuse to participate

Treatment and study plan

Primary outcomes

  1. Main objective

    Time frame: The measures were performed after the CT-Scans were realized. The CT-Scans were performed from October 2016 to February 2018. The measures on the CT-Scans were realized in june 2018

    The main objective of this study was twofold: 1) to assess the anatomical correlation between diaphysis thickness in the diaphyseal screw region of volar plates and epiphyseal thickness in lateral plane with linear regression analysis for each epiphyseal screw length with regard to the diaphysis screw length, and 2) to evaluate whether the optimal epiphyseal screw lengths can be predicted by reference to the diaphyseal screw length when diaphyseal screws are first positioned.

    From the CT-scans, Reconstructions in 3D of the radius were realized. Those reconstructions were used in a computer-simulation study. A Volar plate was affixed to the radius using a specific software.

    Maximum length for each screw located either in epiphysis or diaphysis was measured in mm. This length corresponded with the distance between the entry point of the screw and the opposite point belonging to the wrist along the line perpendicular to the plate.

Sponsors and collaborators

Lead sponsor

University Hospital, Brest

Other

Registry information

Official study title

Volar Plates for Distal Radius : Can Epiphyseal Screw Length be Predicted

Acronym: PESLDRF

Important dates

Study start
2018
Primary completion
2018
Study completion
2018
First posted
Aug 17, 2018
Registry last updated
Aug 17, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.