Samsung S-Viscosity vs Canon Dispersion Slope in Steatotic Liver Disease (SAVID-SLD)

Steatotic liver disease (SLD) is one of the most common chronic liver diseases worldwide. Distinguishing simple steatosis from metabolic dysfunction-associated steatohepatitis (MASH) with significant fibrosis is clinically important, but liver biopsy - the current standard - is invasive. Recent ultrasound technology allows noninvasive measurement of tissue viscoelasticity, which has been linked to liver inflammation. Samsung Medison's HERA W12 system (S-Viscosity) and Canon Aplio i800 (Dispersion Slope Imaging) both provide vendor-specific viscoelasticity parameters derived from shear-wave dispersion analysis, but their relationship and agreement have not been compared in SLD patients.

This prospective single-center observational study will enroll approximately 95-100 participants in three cohorts: (A) 15-20 living-donor candidates as a healthy reference, (B+C) approximately 80 adults with sonographically suspected or confirmed SLD recruited consecutively. SLD participants will be classified post-hoc into low-MASH-risk (Cohort B) and at-risk MASH (Cohort C) subgroups using a multi-parametric stratification combining liver stiffness (LSM), DeepUSFF (deep-learning-based ultrasound fat fraction), and serum AST. All participants will undergo same-day ultrasound examination with both Samsung HERA W12 and Canon Aplio i800. The primary objective is to evaluate the correlation and agreement between Samsung S-Viscosity and Canon Dispersion Slope. Secondary objectives include deriving a normal reference range from the healthy cohort, comparing viscoelasticity parameters across cohorts, and exploring a Modified US-FAST score.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Seoul National University Hospital

Seoul, 03080, South Korea

About this study

Background: Two-dimensional shear wave elastography (2D SWE) is widely used to quantify liver stiffness for fibrosis assessment, but stiffness can be confounded by inflammation, congestion, and other factors. Frequency-dependent shear-wave dispersion analysis yields viscosity-related parameters that may reflect tissue inflammation. Canon's Dispersion Slope Imaging (DS, [m/s]/kHz) has been validated against histology in the multicenter iLEAD study (Sugimoto et al., Radiology 2024) and shown to correlate with lobular inflammation in MASLD. Samsung Medison has recently introduced S-Viscosity within the S-Shearwave platform of the HERA W12 R30 system, providing dispersion-derived viscosity parameters from a single SWE acquisition; however, head-to-head comparison with Canon DS in SLD patients has not been reported.

Hypothesis: Samsung S-Viscosity and Canon Dispersion Slope, both derived from frequency-dependent shear-wave analysis, will demonstrate moderate-to-strong correlation and clinically acceptable inter-vendor agreement in patients with steatotic liver disease.

Study Design: Single-center, prospective, non-interventional observational study. Adult participants (≥18 years) will be enrolled into three cohorts: Cohort A (Healthy reference, n=15-20): living-donor candidates with confirmed steatosis <5%, normal LFTs, and exclusion of chronic liver disease, recruited during routine donor evaluation. Cohort B+C (SLD, n≈80): adults with sonographically suspected or confirmed hepatic steatosis scheduled for clinical abdominal ultrasound, recruited consecutively. Post-hoc stratification of SLD participants uses LSM (2D S-SWE), DeepUSFF, and serum AST with institutionally-validated cutoffs (LSM 6.82 kPa for ≥F2 fibrosis; DeepUSFF asymmetric cutoffs of 7.86% for <S1 rule-out and 15.05% for ≥S2 rule-in; AST 40 U/L institutional ULN) to define Low MASH risk (Cohort B), At-risk MASH (Cohort C), and an Indeterminate zone.

Procedures: All participants undergo same-day ultrasound examinations on both Samsung HERA W12 (CA 1-7S probe) and Canon Aplio i800 (i8C1 probe) in randomized order, with operators blinded to LFT results at the time of scanning. From the right hepatic lobe via right intercostal approach after a minimum 4-hour fast: Samsung acquisitions include 2D S-Viscosity, 2D S-SWE, TAI, and DeepUSFF (5 measurements per parameter, 2 sessions); Canon acquisitions include Dispersion Slope Imaging and 2D SWE (5 measurements). Median values are used as representative.

Statistical Analysis: Primary endpoints - Pearson or Spearman correlation between Samsung S-Viscosity and Canon Dispersion Slope (with 95% CI), and Bland-Altman analysis of inter-vendor agreement (mean bias and 95% limits of agreement). Sample size of approximately 80 SLD participants provides adequate precision for both correlation (r=0.4 to 0.6) and Bland-Altman limits-of-agreement estimation (±0.5 SD precision). Secondary endpoints include 95% reference interval derivation from Cohort A (n≥15 for nonparametric estimation), inter-cohort comparisons, Modified US-FAST score exploration, reproducibility (ICC and CV%), and technical success rate.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • [Cohort A - Healthy reference]
  • Adults ≥18 years old
  • Currently undergoing living-donor evaluation at SNUH
  • Donor evaluation confirms (a) hepatic steatosis <5% by imaging or biopsy, (b) normal AST/ALT, and (c) absence of chronic liver disease (HBV, HCV, autoimmune, cholestatic, etc.)
  • Provided written informed consent [Cohort B + C - Steatotic liver disease]
  • Adults ≥18 years old
  • Sonographically suspected or confirmed hepatic steatosis on B-mode ultrasound, scheduled for clinical abdominal ultrasound
  • Serum AST/ALT results available within 6 weeks of ultrasound, or scheduled
  • Provided written informed consent

Exclusion criteria

  • • Significant alcohol intake within the past 2 years (>30-60 g/day for males, >20-50 g/day for females)
  • Diagnosed or strongly suspected chronic liver disease (active HBV/HCV, autoimmune liver disease, cholestatic liver disease, Wilson's disease, hemochromatosis, etc.)
  • Suspected hepatic failure or decompensated cirrhosis (albumin <3.2 g/dL, INR >1.3, direct bilirubin >1.3 mg/dL)
  • Ascites, history of variceal bleeding, or acute biliary obstruction rendering stable measurements unfeasible
  • History of liver malignancy or treatment for liver malignancy
  • History of liver surgery
  • Pregnancy or lactation
  • Inadequate ultrasound image quality due to obesity, bowel gas, or patient inability to cooperate

Treatment and study plan

Samsung Medison HERA W12 (R30) with S-Shearwave platform

Device

Two-dimensional shear-wave elastography acquisition with the Samsung HERA W12 R30 system using the CA 1-7S convex probe. Five valid measurements per parameter are obtained from the right hepatic lobe via right intercostal approach, repeated in 2 sessions. Output parameters include S-Viscosity (dispersion-derived viscosity index), 2D S-SWE (liver stiffness in kPa), TAI (tissue attenuation imaging), and DeepUSFF (deep-learning-based ultrasound fat fraction in %).

Canon Aplio i800 with Dispersion Slope Imaging

Device

Two-dimensional shear-wave elastography and Dispersion Slope Imaging acquisition with the Canon Aplio i800 system using the i8C1 convex probe. Five valid measurements are obtained from the right hepatic lobe via right intercostal approach. Output parameters include 2D SWE (liver stiffness in kPa) and Dispersion Slope (in [m/s]/kHz, viscosity-related).

Primary outcomes

  1. Correlation between Samsung S-Viscosity and Canon Dispersion Slope

    Time frame: At the time of single study visit (Day 0)

    Pearson or Spearman correlation coefficient (with 95% CI) between Samsung S-Viscosity and Canon Dispersion Slope, calculated from the median of 5 valid measurements per device per participant.

  2. Inter-vendor agreement (Bland-Altman analysis)

    Time frame: At the time of single study visit (Day 0)

    Mean bias and 95% limits of agreement between Samsung S-Viscosity and Canon Dispersion Slope calculated by Bland-Altman analysis. As the two parameters use different units, agreement will also be assessed after z-score transformation

Secondary outcomes

  1. Normal reference range of viscoelasticity parameters

    Time frame: At the time of single study visit (Day 0)

    95% reference interval (2.5-97.5 percentile) of Samsung S-Viscosity and Canon Dispersion Slope estimated nonparametrically from Cohort A (healthy reference cohort).

  2. Inter-cohort comparison of viscoelasticity parameters

    Time frame: At the time of single study visit (Day 0)

    Difference in Samsung S-Viscosity and Canon Dispersion Slope between Cohort B (Low MASH risk) and Cohort C (At-risk MASH), tested by t-test or Mann-Whitney U.

  3. Modified US-FAST score performance (exploratory)

    Time frame: At the time of single study visit (Day 0)

    AUROC of a Modified US-FAST score - calculated by substituting Samsung 2D S-SWE LSM and DeepUSFF into the LSM and CAP positions of the original FAST score formula (Newsome et al., Lancet Gastroenterol Hepatol 2020) - for identifying Cohort C participants. Correlation with Canon Dispersion Slope is also assessed.

  4. Reproducibility of viscoelasticity measurements

    Time frame: At the time of single study visit (Day 0)

    Intraclass correlation coefficient (ICC, 2-way random effects) and coefficient of variation (CV%) of repeated viscoelasticity measurements across two acquisition sessions per device.

  5. Technical success rate

    Time frame: At the time of single study visit (Day 0)

    Proportion of participants in whom valid viscoelasticity measurements were successfully obtained on both devices (Samsung HERA W12 and Canon Aplio i800).

Study contacts

Contact information is provided by the study sponsor or research team.

Jeong Hwan Park, MD

CONTACT

Jeong Min Lee, MD, PhD

CONTACT

[email protected]

+82-2-2072-3154

Sponsors and collaborators

Lead sponsor

Seoul National University Hospital

Other

Registry information

Official study title

Prospective Evaluation of Samsung Medison 2D Shear Wave Elastography Viscoelasticity Parameters in Patients With Steatotic Liver Disease Using Canon Dispersion Slope Imaging as Reference Standard: A Single-Center Non-Interventional Observational Study

Acronym: SAVID-SLD

Important dates

Study start
2026
Primary completion
2026
Study completion
2027
First posted
Apr 15, 2026
Registry last updated
Apr 15, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.