Safety and Efficacy Study of MGuard Stent After a Heart Attack

The goal of this study is to demonstrate the superiority of the MGuard™ stent over commercially-approved bare-metal (BMS) /drug-eluting stents (DES) in achieving better myocardial reperfusion in primary angioplasty for the treatment of acute ST-elevation myocardial infarction (STEMI).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

Klinika Kardiologii Inwazyjnej Uniwersytetu Medycznego w Białymstoku, Bialystok, Poland

Loading trial locations.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • 18 years of age
  • ST-segment elevation (more than 2mm in more than contiguous leads)
  • MI with symptom onset less than 12h
  • The patient is willing to comply with specified follow-up evaluations
  • Signed ICF
  • Single de novo lesion in the target (culprit) vessel
  • Target lesion maximum length is 33 mm (by visual estimation)
  • Reference vessel diameter must be more than 3.0 to less than 4.0 mm by visual estimation
  • Randomization should occur as soon as Presence of TIMI 2 or 3 before randomization Exclusion Criteria
  • Pregnant or nursing patients
  • Left Bundle Branch Block (LBBB), paced rhythm, or other Electrocardiogram (ECG) abnormality
  • Impaired renal function
  • Prior coronary artery bypass graft surgery
  • Bleeding diathesis
  • Contraindication to aspirin
  • cardiopulmonary resuscitation
  • Cardiogenic shock
  • chronic warfarin anticoagulation
  • LVEF less than 20%
  • other medical illness
  • participation in another investigational drug or device study that has not reached its primary endpoint
  • Left main coronary artery disease with 50% stenosis
  • Ostial target lesion
  • Failure to visualize vessel anatomy distal to the culprit lesion
  • Moderate to heavily calcified target lesion or vessel
  • excessive tortuosity
  • bifurcation with a side branch more than 2.0 mm in diameter
  • A significant (greater than 50%) stenosis proximal or distal to the target lesion is present that cannot be covered by same single stent
  • Diffuse disease distal to target lesion with impaired runoff
  • Any prior stent proximal to the target lesion, or within 10 mm distal of the target lesion
  • PCI of another lesion performed within 6 months before the index procedure
  • Target lesion located in a saphenous vein graft

Treatment and study plan

MGuard

Device

MGuard™ stent comprises a balloon-expandable, thin-strut stainless steel (316L) bare metal stent platform (strut width 100 µm) with mesh sleeve fibers of polyethyleneterephtalate (fiber width of 20 µm) attached to its outer surface. These fibers act like a net (aperture size 150 x 180 µm) preventing distal embolization of the plaque debris/thrombus placed between the vessel wall and the stent.

Control BMS or DES

Device

Control BMS or DES

Primary outcomes

  1. The incidence of complete ST segment resolution (defined as ≥70% ST 1. The incidence of complete ST segment resolution

    Time frame: 60 to 90 minutes after the last angiogram

Secondary outcomes

  1. The incidence of Thrombolysis In Myocardial Infarction (TIMI) 3 flow at the end of the procedure.

    Time frame: 60-90 minutes after last angiogram

    The incidence of TIMI 3 flow at the end of the procedure.

  2. Major Adverse Cardiac Events (MACE)at discharge, 30 days, 6 months and 12 months post-procedure

    Time frame: discharge, 30 days, 6 and 12 months post-procedure

    Major Adverse Cardiac Events (MACE): defined as cardiac death, reinfarction (Q wave and non-Q wave), or repeat ischemia-driven target lesion revascularization (TLR) by percutaneous or surgical methods at hospital discharge, 30 days, 6 months and 1 year post-procedure.

Sponsors and collaborators

Lead sponsor

InspireMD

Industry

Registry information

Official study title

MASTER: MGUARD for Acute ST Elevation Reperfusion

Acronym: MASTER

Important dates

Study start
2011
Primary completion
2012
Study completion
2012
First posted
Jun 8, 2011
Registry last updated
May 29, 2013

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.