Safety and Efficacy of the ZoMaxx™ Drug-Eluting Stent System in Coronary Arteries

The purpose of this study is to demonstrate the safety and efficacy of the ZoMaxx drug-eluting stent in patients with blockage of native coronary arteries. The study is designed to demonstrate non-inferiority to the TAXUS Express2 Paclitaxel-Eluting Stent that has proven superior to bare metal stents and is a recognized standard of care.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 2

Primary location

St. Vincent's Hospital Sydney, Darlinghurst, New South Wales, Australia

Loading trial locations.

About this study

Coronary artery disease is the major cause of morbidity and mortality in the United States. The American Heart Association estimates that 571,000 Percutaneous Transluminal Coronary Angioplasty (PTCA) procedures were performed in 2001 in the United States and that 80% to 90% of these patients also underwent stent placement. Despite the effectiveness of intracoronary stents in maintaining a larger luminal diameter as compared to angioplasty alone, 15 to 35% in-stent restenosis occurs within 6 to 9 months after stent placement. While stents can reduce restenosis by blocking vascular recoil and remodeling, mechanical intervention alone is incapable of treating the biological problem of neointimal hyperplasia. Various approaches have been used to treat in-stent restenosis, including balloon angioplasty, repeat stenting, rotational and directional atherectomy, laser, and local delivery of radiation at the time of stenting (brachytherapy). However, these techniques add complexity to the interventional procedure and have not had documented success in preventing in-stent restenosis. Drug-eluting stents (DES) using antiproliferative agents delivered via a polymer based stent platform have shown significant success in the reduction of restenosis in de novo lesions over the traditional bare metal stents in randomized clinical trials. Local delivery of the pharmacological agent allows for controlled delivery of high drug concentrations to the targeted tissue while minimizing systemic drug effects. The ZoMaxx II Trial represents the first US study of the ZoMaxx(TM) Drug Eluting Coronary Stent System to evaluate the potential benefits of the local application of the zotarolimus drug in combination with a phosphorylcholine (PC)-coated tri-metal stent.

ZoMaxx™ Drug-Eluting Stent System is an Investigational device. Limited by Federal (U.S.) law to investigational use only.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

include all of the following:

  • Subject is ≥ 18 years old
  • Subject is eligible for percutaneous coronary intervention (PCI) and has a single lesion requiring treatment
  • Subject is an acceptable candidate for CABG
  • Clinical evidence of ischemic heart disease or a positive functional study
  • Documented stable angina pectoris
  • The target lesion is a single de novo coronary artery lesion with ≥50 and <100% stenosis by visual estimate

Exclusion criteria

include all of the following:

  • Female of childbearing potential. Female subjects must be medically or surgically sterile or diagnosed as post-menopausal (i.e. one year since final menstrual cycle.
  • Evidence of an acute myocardial infarction and/or CK-MB>2x upper limit of normal within 72 hours of the intended treatment
  • Known allergies to the following: aspirin, clopidogrel (Plavix) or ticlopidine (Ticlid), heparin, stainless steel, tantalum, contrast agent (that cannot be adequately premedicated), paclitaxel or drugs similar to zotarolimus (ABT-578) (i.e. tacrolimus, sirolimus, everolimus)
  • A platelet count <100,000 cells/mm3or >700,000 cells/mm3; a WBC <3,000 cells/mm3; or hemoglobin <10.0g/dL
  • Acute or chronic renal dysfunction (creatinine >2.0 mg/dl or >150µmol/L)
  • Subject has had any previous or planned brachytherapy in the target vessel

Treatment and study plan

ZoMaxx™ Drug-Eluting Coronary Stent System

Device

Drug eluting stent implantation stent in the treatment of coronary artery disease.

TAXUS™ EXPRESS2™ Paclitaxel Eluting Coronary Stent

Device

Drug eluting stent implantation stent in the treatment of coronary artery disease.

Primary outcomes

  1. The primary endpoint is TVR (Target Vessel Revascularization). TVR is defined as any ischemia driven repeat percutaneous intervention of the target vessel or bypass surgery of the target vessel.

    Time frame: at 9 months

Secondary outcomes

  1. The major secondary endpoint is in-segment late loss as measured by QCA. In-segment late loss is defined as the difference between the post-procedure minimal luminal diameter (MLD) and the follow-up angiography MLD.

    Time frame: at 9 months

Sponsors and collaborators

Lead sponsor

Abbott Medical Devices

Industry

Registry information

Official study title

A Randomized, Controlled Trial to Evaluate the Safety and Efficacy of the ZoMaxx Drug Eluting Coronary Stent System as Compared to the TAXUS™ Express2™ Paclitaxel-Eluting Stent in de Novo Coronary Artery Lesions

Acronym: ZoMaxx™ II

Important dates

Study start
2005
Primary completion
2007
Study completion
2012
First posted
Sep 1, 2005
Registry last updated
Jan 10, 2012

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.