Symetis ACURATE neo/TF transfemoral TAVI system
DeviceTranscatheter aortic valve implantation of a Symetis ACURATE neo/TF bioprosthesis by transfemoral access, pre-dilatation mandatory.
NCT Number: NCT03011346
Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe symptomatic aortic stenosis and at increased risk for surgical aortic valve replacement (SAVR). Many novel devices are currently being developed and established transcatheter heart valves undergo design reiterations to address limitations and reduce complication rates associated with the device and implantation procedure. However, device comparisons by use of randomized trials are scarce in particular for newer generation transcatheter valves. The aim of this study is to assess non-inferiority of the self-expandable Symetis ACURATE neo/TF in comparison to the balloon-expandable Edwards SAPIEN 3 transcatheter aortic valve bioprosthesis with regard to early safety and clinical efficacy at 30 days.
Looking for future studies?
Notify Me75 year and older
All sexes
Interventional
Not applicable
Herz- und Gefäss-Klinik GmbH Bad Neustadt, Bad Neustadt an der Saale, Bad Neustadt, Germany
Background:
Transcatheter aortic valve implantation (TAVI) is an established and valuable treatment option for patients with severe symptomatic aortic stenosis and at increased risk for surgical aortic valve replacement (SAVR). The use of TAVI is rapidly expanding worldwide and the indications for TAVI are widening into lower risk populations in view of favorable outcomes among high and intermediate risk patients. Many novel devices are currently developed or established devices undergo design reiterations to address limitations, such as vascular access complications, paravalvular regurgitation, and atrio-ventricular conductance disturbances. However, device comparisons by use of randomized trials are scarce in particular for newer generation transcatheter valves.
The Symetis ACURATE neo/TF, a self-expandable transcatheter valve delivered via transfemoral access, gained Conformité Européenne (CE) marking in September 2014 after showing favorable procedural and short term results. The SCOPE I trial will compare its performance to the balloon-expandable Edwards SAPIEN 3, a widely used and well-established transcatheter heart valve of the second generation, in a randomized fashion.
Objectives:
The primary objective is the comparison of the Symetis ACURATE neo/TF to the Edwards SAPIEN 3 transcatheter aortic bioprosthesis with regard to early safety and clinical efficacy at 30 days. Secondary objectives involve the comparison between the two devices with regard to secondary clinical and echocardiographic endpoints at 30 days, 1 year and 3 years.
Methods:
Sample Size: Based on an anticipated incidence proportion of 22% for the primary non-hierarchical composite endpoint at 30 days in both treatment arms, a non-inferiority margin of 7.7%, a power of 80%, a one-tailed significance level of α = 0.05, and a low attrition rate, the total required sample size amounts to 730 patients.
Design: Patients will be allocated to the Symetis ACURATE neo/TF or the Edwards SAPIEN 3 bioprosthesis at a 1:1 ratio by means of a randomly permuted block randomisation stratified on study center and Society of Thoracic Surgeons' predicted risk of mortality score (STS-PROM) strata (< 3%, ≥ 3 to < 8%, ≥ 8%).
Analysis: Estimates of the risk-differences between the two treatment arms with regard to the primary endpoint will be pooled over the predefined STS-PROM strata by means of the Cochran-Mantel-Haenszel method and Wald-type confidence limits will be calculated using the Sato variance estimator. The non-inferiority assumption will be tested at a one-sided significance level with a type I error rate (α) = 0.05. The analysis of the primary composite endpoint will be conducted according to the intention-to-treat (ITT) and the per protocol (PP) principle and non-inferiority should be claimed only if met by both.
In case non-inferiority is established, a superiority analysis will be performed using a two-tailed significance level with a type I error rate of α = 0.05. Further secondary analyses will evaluate between group differences in relation to demographic, clinical, procedural, functional and imaging characteristics. Pre-specified subgroup analyses will be conducted by use of appropriate interaction tests contrasting categories of sex, STS-PROM score (< 3%, ≥ 3 to < 8%, ≥ 8%), left ventricular ejection fraction (< 50% vs. ≥ 50%), and native aortic valve eccentricity index (≤ 0.25 vs. > 0.25).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Transcatheter aortic valve implantation of a Symetis ACURATE neo/TF bioprosthesis by transfemoral access, pre-dilatation mandatory.
Transcatheter aortic valve implantation of an Edwards Sapien 3 bioprosthesis by transfemoral access.
Time frame: 30 days
(* "NYHA class III or IV" is omitted due to lack of objectiveness in its ascertainment)
Time frame: 30 days
Combined endpoint composed of:
Time frame: 30 days
Combined endpoint composed of:
Time frame: 30 days
Combined endpoint composed of:
Time frame: 30 days, 1 year
Combined endpoint composed of:
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Prosthetic aortic valve stenosis: mean gradient ≥ 20 mmHg, EOA ≤ 0.9-1.1cm2 and/or DVI < 0.35)
Time frame: procedural
Time frame: procedural
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Any thrombus attached to or near an implanted valve that occludes part of the blood flow path, interferes with valve function, or is sufficiently large to warrant treatment. Note that valve-associated thrombus identified at autopsy in a patient whose cause of death was not valve-related should not be reported as valve thrombosis.
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Time frame: 30 days, 1 year, 3 years
Insel Gruppe AG, University Hospital Bern
Other
Safety and Efficacy of the Symetis ACURATE Neo/TF Compared to the Edwards SAPIEN 3 Bioprosthesis for Transcatheter Aortic Valve Implantation by Transfemoral Approach.
Acronym: SCOPE I
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02729519
Aortic Valve Disease, Aortic Valve Stenosis
Montpellier, France
View Trial DetailsNCT07605780
Aortic Valve Disease, Aortic Valve Stenosis
Brescia, BS, Italy
View Trial DetailsNCT06171802
Aortic Valve Disease, Aortic Valve Stenosis
Copenhagen, Denmark
View Trial DetailsNCT05774691
Aortic Valve Disease, Aortic Valve Stenosis
Aalst, Belgium
View Trial Details